Sunil Muthuswamy 7a3b7f6b94 win32: boot broken when bind & data dir are the same
With upstream commit#ea1edcd7da1a "vl: relocate paths to data
directories", the data dir logic was unified between POSIX &
Win32. That patch moved to using 'get_relocated_path()', to
find the data dir. There is a latent bug in get_relocated_path
which can cause it to spin indefinitely, when the bind dir is
the same as the passed in dir (in this case, it was the data
dir).

Signed-off-by: Sunil Muthuswamy <sunilmut@microsoft.com>
Message-Id: <SN4PR2101MB08802BF242C429A15DDB32ACC01B0@SN4PR2101MB0880.namprd21.prod.outlook.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2020-10-26 07:08:39 -04:00
..