Philippe Mathieu-Daudé 0773885236 hw/char/pl011: Replace magic values by register field definitions
0x400 is Data Register Break Error (DR_BE),
0x10 is Line Control Register Fifo Enabled (LCR_FEN)
and 0x1 is Send Break (LCR_BRK).

Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
Reviewed-by: Alex Bennée <alex.bennee@linaro.org>
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Message-Id: <20230522153144.30610-7-philmd@linaro.org>
2023-08-31 19:47:43 +02:00
..
2023-07-25 14:40:49 +02:00