Add the parameter 'order' to qemu_register_reset and sort callbacks on
registration. On system reset, callbacks with lower order will be
invoked before those with higher order. Update all existing users to the
standard order 0.
Note: At least for x86, the existing users seem to assume that handlers
are called in their registration order. Therefore, the patch preserves
this property. If someone feels bored, (s)he could try to identify this
dependency and express it properly on callback registration.
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
Attached patch adds a reset handler to parallel port, so it gets correct
register values after a reset.
(Hervé Poussineau)
git-svn-id: svn://svn.savannah.nongnu.org/qemu/trunk@5942 c046a42c-6fe2-441c-8c8c-71466251a162
The direction bit in the control register should not be directly
set using PPWCONTROL. The kernel gives the following debug message.
parport0 (ppdev0): use data_reverse for this!
More over setting the data pins to forward mode does not work,
perhaps a bug in the Linux PP driver. The right way to do this is
to use PPDATADIR to set the direction. The patch checks if the
user is toggling the direction bit, and invokes PPDATADIR to
do the job.
Signed-off-by: Vijay Kumar B <vijaykumar@bravegnu.org>
Signed-off-by: Aurelien Jarno <aurelien@aurel32.net>
git-svn-id: svn://svn.savannah.nongnu.org/qemu/trunk@5063 c046a42c-6fe2-441c-8c8c-71466251a162