ml605_mmu: Move the hardcoded values to the init function
Move the hard coded register values to the init function. This also allows the entire reset function to be deleted, as PVR registers are now preserved on reset. The hardcoded PVR0 values can be removed as they are setting the endianness and stack protection, which is already done or invalid. Signed-off-by: Alistair Francis <alistair.francis@xilinx.com> Reviewed-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com> Signed-off-by: Edgar E. Iglesias <edgar.iglesias@xilinx.com>
This commit is contained in:
parent
6fad9e986b
commit
a87310a62d
@ -64,17 +64,6 @@
|
||||
#define SPI_IRQ 4
|
||||
#define UART16550_IRQ 5
|
||||
|
||||
static void machine_cpu_reset(MicroBlazeCPU *cpu)
|
||||
{
|
||||
CPUMBState *env = &cpu->env;
|
||||
|
||||
env->pvr.regs[10] = 0x0e000000; /* virtex 6 */
|
||||
/* setup pvr to match kernel setting */
|
||||
env->pvr.regs[0] |= (0x14 << 8);
|
||||
env->pvr.regs[4] = 0xc56b8000;
|
||||
env->pvr.regs[5] = 0xc56be000;
|
||||
}
|
||||
|
||||
static void
|
||||
petalogix_ml605_init(MachineState *machine)
|
||||
{
|
||||
@ -205,10 +194,15 @@ petalogix_ml605_init(MachineState *machine)
|
||||
}
|
||||
}
|
||||
|
||||
/* setup PVR to match kernel settings */
|
||||
cpu->env.pvr.regs[4] = 0xc56b8000;
|
||||
cpu->env.pvr.regs[5] = 0xc56be000;
|
||||
cpu->env.pvr.regs[10] = 0x0e000000; /* virtex 6 */
|
||||
|
||||
microblaze_load_kernel(cpu, MEMORY_BASEADDR, ram_size,
|
||||
machine->initrd_filename,
|
||||
BINARY_DEVICE_TREE_FILE,
|
||||
machine_cpu_reset);
|
||||
NULL);
|
||||
|
||||
}
|
||||
|
||||
|