NetBSD/sys/arch/sgimips
tsutsui ca49b6380d Fix a typo. (from OpenBSD) 2005-05-18 14:57:36 +00:00
..
compile Rework how KERNOBJDIR functions; now it's always determined with 2003-01-06 17:40:18 +00:00
conf assign major for nsmb(4) 2005-05-10 00:02:35 +00:00
dev Print board identification, same as we do on the IP2x machines. 2004-11-12 23:01:01 +00:00
eisa __KERNEL_RCSID() 2003-07-15 02:54:31 +00:00
gio regen 2005-04-17 04:07:11 +00:00
hpc Attempt to verify presence of haltwo hardware, rather than just blithely 2005-02-28 07:42:53 +00:00
include Add a dm_maxsegsz public member to bus_dmamap_t. This allows a user of the API 2005-03-09 19:04:43 +00:00
ioc Add dedicated IOC (I/O Controller) driver. pckbc, zstty, and lpt will each 2003-12-15 10:23:52 +00:00
mace Fix a typo. (from OpenBSD) 2005-05-18 14:57:36 +00:00
pci Use ANSI function declarations. 2004-09-29 04:06:51 +00:00
sgimips Move the MI printing of `copyright' to the MD cpu_startup() code 2005-04-25 15:02:02 +00:00
stand Link ip3xboot as OMAGIC by -N option for ld(1) so that the firmware on O2 2005-04-23 10:47:22 +00:00
xio
Makefile Rework how KERNOBJDIR functions; now it's always determined with 2003-01-06 17:40:18 +00:00
README.IPn Correct the names of a few system types. 2004-09-29 07:37:02 +00:00
TODO Update TODO list. 2005-03-01 03:17:40 +00:00

README.IPn

$NetBSD: README.IPn,v 1.6 2004/09/29 07:37:02 soren Exp $

Arch (kernel)	Models				Codename
-------------	------				--------
IP2		IRIS 3000
IP4		4D/50, 4D/70
IP4.5		4D/60, 4D/80, 4D/85
IP5		4D/1x0
IP6		4D/20
IP10 (IP6)	4D/25
IP7		4D/2x0
IP9		4D/210
IP13 (IP7)	4D/3x0
IP15 (IP7)	4D/4x0
IP12		4D/30, 4D/35, Indigo R3K
IP17		Crimson
IP19		Challenge L/XL, Onyx		Everest
IP20		Indigo R4K
IP21		Power Challenge R8K, Power Onyx	Everest
IP22		Indigo2, Challenge M		Fullhouse
IP24 (IP22)	Indy, Challenge S 		Guiness
IP25		Power Challenge R10K		Everest
IP26		Power Indigo2 R8K		Teuton
IP27		Origin 200, Origin 2000, Onyx2
IP28		Power Indigo2 R10K		Pacecar
IP30		Octane				Speedracer
IP32		O2				Moosehead
IP33		SN1 (?)
IP35		SN1 (?)

Architecture	ABI	Bootstrap Load Address	Kernel Load Address
------------	---	----------------------	-------------------
IP19 IP21 IP25	32	0x80004000		0x80100000
IP19 IP21 IP25	64	0xa800000000004000	0xa800000000180000
IP20 IP22 IP24	32	0x88002000		0x88069000
IP22 IP24 IP26	64	0xa800000008002000	0xa800000008069000
IP28		64	0xa800000020003000	0xa800000020080000
IP30		64	0xa800000020004000	0xa800000020080000
IP32		32	0x80002000		0x80069000
IP32		64	0xa800000000002000	0xa800000000078000
IP33		64	0xa800000000019000	0xa800000000300000