poll() is specified in POSIX.1-2001 as a simpler interface for
multiplexed file descriptors than select(). It also provides more
functionality.
This PR replaces the select() calls used in xrdp with poll()
equivalents.
- Update pixman-region.h header
-- Reformat so all lines fit within 80 characters.
-- Update define guard to use convention for the rest of XRDP.
Add pixman_region_not_empty and pixman_region_extents in anticipation of
using it for EGFX in the future.
Moving to a uid_t to store the user information makes a lot
of sense. When doing this, we need a function to get information
about a user from the uid_t
As well as creating the function g_getuser_info_by_uid() we also
rename g_getuser_info() to g_getuser_info_by_name() and make the
parameter ordering more usual.
Detect attempts to overflow input buffer
If application code hasn't properly sanitised the header_size
for a transport, it is possible for read requests to be issued
which overflow the input buffer. This change detects this
at a low level and bounces the read request.
To implement a scalable login screen, we need to be able to ascertain
the DPI of the connected primary monitor.
At present, in a multi-monitor situation, this information is available in
the struct display_size_description, which can be searched for the primary
monitor. This is only the case however if the Display Control Channel
Extension is in use ([MS-RDPEDISP]), and a DISPLAYCONTROL_MONITOR_LAYOUT
has been received.
This PR retrieves physical monitor size information from the following
two additional places.
1) The TS_UD_CS_CORE PDU. Physical size information is optionally
included in this PDU for single-screen configurations.
2) The TS_UD_CS_MONITOR_EX PDU. This includes physical size
information for multiple-screen configurations.
The connected client is currently described in two places in
the xrdp_client_info structure:-
1) In the connection_description field. This was introduced as
field client_ip by commit d797b2cf49
for xrdp v0.6.0
2) In the client_addr and client_port fields introduced by commit
25369460a1 for xrdp v0.8.0
This commit unifies these two sets of fields into a single
set of fields describing the connection IP and port (for
AF_INET/AF_INET6 connections only) and a connection description
for all connection types.
The code in os_calls to provide client logging has been simplified
somewhat which should make it easier to add new connection types (e.g.
AF_VSOCK).
The old connection_description field used to be passed to sesman to
inform sesman of the IP address of the client, and also to provide
a string for 'C' field session policy matching. 'C' field session policy
matching does not actually need this string (see #2239), and so now only
the IP field is passed to sesman.
The TCP socket implementation of sesman has a number of limitations,
namely that it is affected by firewalls, and also that determining the
user on the other end requires a full authentication process.
The advantage of the TCP socket is that sesman and xrdp can be run on
separate machines. This is however not supported by the xorgxrdp
backend (shared memory), and is insecure, in that passwords are sent
in-the-clear, and the connection is susceptible to MitM attacks. This
architecture has been deprecated in release notes since xrdp v0.9.17,
and although it will continue to be supported in any further releases
in the x0.9.x series, it will not be supported in the next major
version.
This is required for PAM systems that depend on group membership being
available during PAM processing. This is used by pam_group on FreeBSD
and pam_group on Linux-PAM, although the functionality of both is
different.
There are a number of ways the existing transport connect logic in
trans_connect could be improved for POSIX compatibility, and also
slightly tidied up:-
1) The same socket is re-used for multiple connect attempts following
failure which isn't behaviour defined by POSIX.1-2017 (although it
works on Linux).
2) An asynchronous connect is started, and then after a short
delay connect() is called again on the same socket. POSIX.1-2017
is clear that in this situation EALREADY is returned before the
connection is established, but is silent on the behaviour expected
when the connection is established. Returning success is an option,
but so is returning EISCONN. The current code assumes the connect()
call will succeed.
3) The code contains two virtually identical, quite complex loops for
TCP and UNIX sockets, differing only in the calls to create a socket
and connect it.
4) trans_connect() contains looping and retry logic, but this isn't
seen as sufficient by the chansrv connect code in xrdp/xrdp_mm.c and
the Xorg connect code in xup/xup.c. Both of these implement their own
looping and retry logic on top of the logic in trans_connect(),
resulting in slightly unpredictable behaviour with regard to
timeouts.
5) A socket number can technically be zero, but in a couple of places
this isn't allowed for.
This PR attempts to correct the implementation of trans_connect(),
and also to simplify the areas it is called from.
As part of the PR, the signature of the server_is_term member of the
xrdp module interface is changed to match the signature expected by the
is_term member of a struct trans. This allows for trans_connect()
in xrdp modules to directly access g_is_term() within the main xrdp
executable. At the moment this functionality is only used by the xup
module.
- Eliminate duplicaiton for display_size_description
- monitorCount needs to be uint32_t
- width/height -> session_width/session_height
- Update CLIENT_INFO_CURRENT_VERSION
- Also some misc unit test updates.
- Minor log updates.
There are two places where monitor descriptions are passed through the
RDP protocol:
- TS_UD_CS_MONITOR ([MS-RDPBCGR] 2.2.1.3.6 Client Monitor Data)
- DISPLAYCONTROL_PDU_TYPE_MONITOR_LAYOUT ([MS-RDPEDISP] 2.2.2.2)
The processing logic for both of them is similar enough that they should be unified.
Also update to define the constants for the maximum and minimum desktop width/height for monitors and total area.
Also a large number of clarifications for the constants and protocol
requirements.
Note that this is also the first step to making resizing work with the extension GFX channel as well as an important
foundational step to enable HiDPI compatibility.
Also some misc logging updates.