Commit Graph

3 Commits

Author SHA1 Message Date
Bryce Harrington
1f6b0d1d2c clients: Update boilerplate from MIT X11 license to MIT Expat licenses 2015-06-15 13:04:18 -07:00
Pekka Paalanen
6c71aaeec5 Pass config file from compositor to everything
We have the Weston command line option '--no-config' which is meant to
prevent loading weston.ini at all. It works for Weston itself, but it
does not work for any clients that also want to read weston.ini.

To fix that, introduce a new environment variable WESTON_CONFIG_FILE.
Weston will set it to the absolute path of the config file it loads.
Clients will load the config file pointed to by WESTON_CONFIG_FILE. If
the environment variable is set but empty, no config file will be
loaded. If the variable is unset, things fall back to the default
"weston.ini".

Note, that Weston will only set WESTON_CONFIG_FILE, it never reads it.
The ability to specify a custom config file to load will be another patch.

All programs that loaded "weston.ini" are modified to honour
WESTON_CONFIG_FILE.

Signed-off-by: Pekka Paalanen <pekka.paalanen@collabora.co.uk>
Reviewed-by: Jonny Lamb <jonny.lamb@collabora.co.uk>
Reviewed-by: Nobuhiko Tanibata <NOBUHIKO_TANIBATA@xddp.denso.co.jp>
Reviewed-by: Bryce Harrington <bryce@osg.samsung.com>
2015-03-27 09:38:12 +02:00
Nobuhiko Tanibata
923bc14097 clients: a reference implementation of UI client how to use ivi-hmi-controller.
- introduces ivi-shell-user-interface.c

This is launched from hmi-controller by launch_hmi_client_process and
invoke a
client process.

The basic flow is as followed,
1/ process invoked
2/ read configuration from weston.ini.
3/ draw png file to surface according to configuration of weston.ini
4/ all parts of UI are ready. request "UI_ready" to draw UI.
5/ Enter event loop
6/ If a surface receives touch/pointer event, followings are invoked
according
   to type of event and surface
6-1/ If a surface to launch ivi_application receive touch up, it execs
     ivi-application configured in weston.ini.
6-2/ If a surface to switch layout mode receive touch up, it sends a
request,
     ivi_hmi_controller_switch_mode, to hmi-controller.
6-3/ If a surface to show workspace having launchers, it sends a
request,
     ivi_hmi_controller_home, to hmi-controller.
6-4/ If touch down events happens in workspace,
     ivi_hmi_controller_workspace_control is sent to slide workspace.
     When control finished, event:
ivi_hmi_controller_workspace_end_control
     is received.

Signed-off-by: Nobuhiko Tanibata <NOBUHIKO_TANIBATA@xddp.denso.co.jp>
Acked-by: Pekka Paalanen <pekka.paalanen@collabora.co.uk>
2014-12-04 17:13:42 +02:00