0181e23713
Remove panic-on-error from IPL functions such that a return code is propagated back to the main IPL calling function (rather than terminating immediately), which facilitates possible error recovery in the future. A select few panics remain, which indicate fatal non-devices errors that must result in termination. Signed-off-by: Jared Rossi <jrossi@linux.ibm.com> Reviewed-by: Thomas Huth <thuth@redhat.com> Message-ID: <20241020012953.1380075-13-jrossi@linux.ibm.com> Signed-off-by: Thomas Huth <thuth@redhat.com>
237 lines
5.9 KiB
C
237 lines
5.9 KiB
C
/*
|
|
* Virtio driver bits
|
|
*
|
|
* Copyright (c) 2013 Alexander Graf <agraf@suse.de>
|
|
*
|
|
* This work is licensed under the terms of the GNU GPL, version 2 or (at
|
|
* your option) any later version. See the COPYING file in the top-level
|
|
* directory.
|
|
*/
|
|
|
|
#include <stdio.h>
|
|
#include "s390-ccw.h"
|
|
#include "virtio.h"
|
|
#include "virtio-scsi.h"
|
|
|
|
#define VIRTIO_BLK_F_GEOMETRY (1 << 4)
|
|
#define VIRTIO_BLK_F_BLK_SIZE (1 << 6)
|
|
|
|
static int virtio_blk_read_many(VDev *vdev, unsigned long sector, void *load_addr,
|
|
int sec_num)
|
|
{
|
|
VirtioBlkOuthdr out_hdr;
|
|
u8 status;
|
|
VRing *vr = &vdev->vrings[vdev->cmd_vr_idx];
|
|
|
|
/* Tell the host we want to read */
|
|
out_hdr.type = VIRTIO_BLK_T_IN;
|
|
out_hdr.ioprio = 99;
|
|
out_hdr.sector = virtio_sector_adjust(sector);
|
|
|
|
vring_send_buf(vr, &out_hdr, sizeof(out_hdr), VRING_DESC_F_NEXT);
|
|
|
|
/* This is where we want to receive data */
|
|
vring_send_buf(vr, load_addr, virtio_get_block_size() * sec_num,
|
|
VRING_DESC_F_WRITE | VRING_HIDDEN_IS_CHAIN |
|
|
VRING_DESC_F_NEXT);
|
|
|
|
/* status field */
|
|
vring_send_buf(vr, &status, sizeof(u8),
|
|
VRING_DESC_F_WRITE | VRING_HIDDEN_IS_CHAIN);
|
|
|
|
/* Now we can tell the host to read */
|
|
vring_wait_reply();
|
|
|
|
if (drain_irqs(vr->schid)) {
|
|
/* Well, whatever status is supposed to contain... */
|
|
status = 1;
|
|
}
|
|
return status;
|
|
}
|
|
|
|
int virtio_read_many(unsigned long sector, void *load_addr, int sec_num)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
return virtio_blk_read_many(vdev, sector, load_addr, sec_num);
|
|
case VIRTIO_ID_SCSI:
|
|
return virtio_scsi_read_many(vdev, sector, load_addr, sec_num);
|
|
}
|
|
|
|
return -1;
|
|
}
|
|
|
|
unsigned long virtio_load_direct(unsigned long rec_list1, unsigned long rec_list2,
|
|
unsigned long subchan_id, void *load_addr)
|
|
{
|
|
u8 status;
|
|
int sec = rec_list1;
|
|
int sec_num = ((rec_list2 >> 32) & 0xffff) + 1;
|
|
int sec_len = rec_list2 >> 48;
|
|
unsigned long addr = (unsigned long)load_addr;
|
|
|
|
if (sec_len != virtio_get_block_size()) {
|
|
return 0;
|
|
}
|
|
|
|
printf(".");
|
|
status = virtio_read_many(sec, (void *)addr, sec_num);
|
|
if (status) {
|
|
return 0;
|
|
}
|
|
addr += sec_num * virtio_get_block_size();
|
|
|
|
return addr;
|
|
}
|
|
|
|
int virtio_read(unsigned long sector, void *load_addr)
|
|
{
|
|
return virtio_read_many(sector, load_addr, 1);
|
|
}
|
|
|
|
/*
|
|
* Other supported value pairs, if any, would need to be added here.
|
|
* Note: head count is always 15.
|
|
*/
|
|
static inline u8 virtio_eckd_sectors_for_block_size(int size)
|
|
{
|
|
switch (size) {
|
|
case 512:
|
|
return 49;
|
|
case 1024:
|
|
return 33;
|
|
case 2048:
|
|
return 21;
|
|
case 4096:
|
|
return 12;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
VirtioGDN virtio_guessed_disk_nature(void)
|
|
{
|
|
return virtio_get_device()->guessed_disk_nature;
|
|
}
|
|
|
|
void virtio_assume_iso9660(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
vdev->guessed_disk_nature = VIRTIO_GDN_SCSI;
|
|
vdev->config.blk.blk_size = VIRTIO_ISO_BLOCK_SIZE;
|
|
vdev->config.blk.physical_block_exp = 0;
|
|
vdev->blk_factor = VIRTIO_ISO_BLOCK_SIZE / VIRTIO_SECTOR_SIZE;
|
|
break;
|
|
case VIRTIO_ID_SCSI:
|
|
vdev->scsi_block_size = VIRTIO_ISO_BLOCK_SIZE;
|
|
break;
|
|
}
|
|
}
|
|
|
|
void virtio_assume_eckd(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
vdev->guessed_disk_nature = VIRTIO_GDN_DASD;
|
|
vdev->blk_factor = 1;
|
|
vdev->config.blk.physical_block_exp = 0;
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
vdev->config.blk.blk_size = VIRTIO_DASD_DEFAULT_BLOCK_SIZE;
|
|
break;
|
|
case VIRTIO_ID_SCSI:
|
|
vdev->config.blk.blk_size = vdev->scsi_block_size;
|
|
break;
|
|
}
|
|
vdev->config.blk.geometry.heads = 15;
|
|
vdev->config.blk.geometry.sectors =
|
|
virtio_eckd_sectors_for_block_size(vdev->config.blk.blk_size);
|
|
}
|
|
|
|
bool virtio_ipl_disk_is_valid(void)
|
|
{
|
|
int blksize = virtio_get_block_size();
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
if (vdev->guessed_disk_nature == VIRTIO_GDN_SCSI ||
|
|
vdev->guessed_disk_nature == VIRTIO_GDN_DASD) {
|
|
return true;
|
|
}
|
|
|
|
return (vdev->senseid.cu_model == VIRTIO_ID_BLOCK ||
|
|
vdev->senseid.cu_model == VIRTIO_ID_SCSI) &&
|
|
blksize >= 512 && blksize <= 4096;
|
|
}
|
|
|
|
int virtio_get_block_size(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
return vdev->config.blk.blk_size;
|
|
case VIRTIO_ID_SCSI:
|
|
return vdev->scsi_block_size;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
uint8_t virtio_get_heads(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
return vdev->config.blk.geometry.heads;
|
|
case VIRTIO_ID_SCSI:
|
|
return vdev->guessed_disk_nature == VIRTIO_GDN_DASD
|
|
? vdev->config.blk.geometry.heads : 255;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
uint8_t virtio_get_sectors(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
return vdev->config.blk.geometry.sectors;
|
|
case VIRTIO_ID_SCSI:
|
|
return vdev->guessed_disk_nature == VIRTIO_GDN_DASD
|
|
? vdev->config.blk.geometry.sectors : 63;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
uint64_t virtio_get_blocks(void)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
const uint64_t factor = virtio_get_block_size() / VIRTIO_SECTOR_SIZE;
|
|
|
|
switch (vdev->senseid.cu_model) {
|
|
case VIRTIO_ID_BLOCK:
|
|
return vdev->config.blk.capacity / factor;
|
|
case VIRTIO_ID_SCSI:
|
|
return vdev->scsi_last_block / factor;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
int virtio_blk_setup_device(SubChannelId schid)
|
|
{
|
|
VDev *vdev = virtio_get_device();
|
|
|
|
vdev->guest_features[0] = VIRTIO_BLK_F_GEOMETRY | VIRTIO_BLK_F_BLK_SIZE;
|
|
vdev->schid = schid;
|
|
virtio_setup_ccw(vdev);
|
|
|
|
puts("Using virtio-blk.");
|
|
|
|
return 0;
|
|
}
|