qemu/hw/m68k/Kconfig
Peter Maydell 9526486164 hw/m68k/q800: Don't connect two qemu_irqs directly to the same input
The q800 board code connects both of the IRQ outputs of the ESCC
to the same pic[3] qemu_irq. Connecting two qemu_irqs outputs directly
to the same input is not valid as it produces subtly wrong behaviour
(for instance if both the IRQ lines are high, and then one goes
low, the PIC input will see this as a high-to-low transition
even though the second IRQ line should still be holding it high).

This kind of wiring needs an explicitly created OR gate; add one.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Reviewed-by: Laurent Vivier <laurent@vivier.eu>
Message-Id: <20201106235109.7066-2-peter.maydell@linaro.org>
Signed-off-by: Laurent Vivier <laurent@vivier.eu>
2020-12-12 18:05:30 +01:00

26 lines
348 B
Plaintext

config AN5206
bool
select COLDFIRE
select PTIMER
config MCF5208
bool
select COLDFIRE
select PTIMER
config NEXTCUBE
bool
select FRAMEBUFFER
select ESCC
config Q800
bool
select MAC_VIA
select NUBUS
select MACFB
select SWIM
select ESCC
select ESP
select DP8393X
select OR_IRQ