Bin Meng a47ef6e93a hw/riscv: clint: Avoid using hard-coded timebase frequency
At present the CLINT timestamp is using a hard-coded timebase
frequency value SIFIVE_CLINT_TIMEBASE_FREQ. This might not be
true for all boards.

Add a new 'timebase-freq' property to the CLINT device, and
update various functions to accept this as a parameter.

Signed-off-by: Bin Meng <bin.meng@windriver.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Message-Id: <1598924352-89526-16-git-send-email-bmeng.cn@gmail.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>