For s390x, the only unaligned accesses that are signaled are atomic,
and we don't actually want to raise SIGBUS for those, but instead
raise a SPECIFICATION error, which the kernel will report as SIGILL.
Split out a do_unaligned_access function to share between the user-only
s390x_cpu_record_sigbus and the sysemu s390x_do_unaligned_access.
Reviewed-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Signed-off-by: Richard Henderson <richard.henderson@linaro.org>