Anything that moves hundreds of lines out of vl.c can't be all bad.
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
Use the correct qdev property type for these devices.
Signed-off-by: Gerd Hoffmann <kraxel@redhat.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
This patch adds a 'index' property to the isa-parallel and isa-serial
devices. This can be used to create devices with the default isa irqs
and ioports by simply specifying the index, i.e.
-device isa-serial,index=1
instead of
-device isa-serial,iobase=0x2f8,irq=3
for ttyS1 aka com2. Likewise for parallel ports.
Signed-off-by: Gerd Hoffmann <kraxel@redhat.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
Some callers test for != 0, some for < 0. Normalize to < 0.
Patchworks-ID: 35171
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
In the very least, a change like this requires discussion on the list.
The naming convention is goofy and it causes a massive merge problem. Something
like this _must_ be presented on the list first so people can provide input
and cope with it.
This reverts commit 99a0949b72.
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
This reverts commit 8217606e6e (and
updates later added users of qemu_register_reset), we solved the
problem it originally addressed less invasively.
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
The parameter is always zero except when registering the three internal
io regions (ROM, unassigned, notdirty). Remove the parameter to reduce
the API's power, thus facilitating future change.
Signed-off-by: Avi Kivity <avi@redhat.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
Add the parameter 'order' to qemu_register_reset and sort callbacks on
registration. On system reset, callbacks with lower order will be
invoked before those with higher order. Update all existing users to the
standard order 0.
Note: At least for x86, the existing users seem to assume that handlers
are called in their registration order. Therefore, the patch preserves
this property. If someone feels bored, (s)he could try to identify this
dependency and express it properly on callback registration.
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
Signed-off-by: Anthony Liguori <aliguori@us.ibm.com>
Attached patch adds a reset handler to parallel port, so it gets correct
register values after a reset.
(Hervé Poussineau)
git-svn-id: svn://svn.savannah.nongnu.org/qemu/trunk@5942 c046a42c-6fe2-441c-8c8c-71466251a162
The direction bit in the control register should not be directly
set using PPWCONTROL. The kernel gives the following debug message.
parport0 (ppdev0): use data_reverse for this!
More over setting the data pins to forward mode does not work,
perhaps a bug in the Linux PP driver. The right way to do this is
to use PPDATADIR to set the direction. The patch checks if the
user is toggling the direction bit, and invokes PPDATADIR to
do the job.
Signed-off-by: Vijay Kumar B <vijaykumar@bravegnu.org>
Signed-off-by: Aurelien Jarno <aurelien@aurel32.net>
git-svn-id: svn://svn.savannah.nongnu.org/qemu/trunk@5063 c046a42c-6fe2-441c-8c8c-71466251a162