Enhance the fault detection.
Fixup the precedence to check the destination path existance
before checking for the source accessibility.
Add the maxstbl entry to both the Query PCI Function Group
response and the PCIBusDevice structure.
Initialize the maxstbl to 128 per default until we get
the actual data from the hardware.
Signed-off-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Reviewed-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Message-Id: <1512046530-17773-5-git-send-email-pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
Enhance the fault detection, correction of the fault reporting.
Signed-off-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Reviewed-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Message-Id: <1512046530-17773-3-git-send-email-pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
Once we wire up TCG, we will need the retaddr to correctly inject
program interrupts. As we want to get rid of the function
program_interrupt(), convert PCI code too.
For KVM, we can simply use RA_IGNORED.
Convert program_interrupt() to s390_program_interrupt() directly, making
use of the passed address.
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Reviewed-by: Thomas Huth <thuth@redhat.com>
Signed-off-by: David Hildenbrand <david@redhat.com>
Message-Id: <20171130162744.25442-6-david@redhat.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
Currently S390PCIIOMMU is a normal struct. Let's make it inherit Object
in order to take advantage of QOM. In addition, we move some stuff
related to IOMMU from S390PCIBusDevice to S390PCIIOMMU.
Signed-off-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Acked-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Tracked down with an ugly, brittle and probably buggy Perl script.
Also move includes converted to <...> up so they get included before
ours where that's obviously okay.
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Reviewed-by: Eric Blake <eblake@redhat.com>
Tested-by: Eric Blake <eblake@redhat.com>
Reviewed-by: Richard Henderson <rth@twiddle.net>
The uid-checking facility guarantees uniqueness of the uid within the
vm and exposes the real uid to the guest when listing pci devices.
Let's always enable it and present it to the guest in the response to
the list pci clp command.
Signed-off-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Reviewed-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Current code uses some fields combinatorially to indicate the state of
a s390 pci device. This patch introduces device states in order to make
the code more readable and more logical.
Signed-off-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Reviewed-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Enhance error handling for mpcifc_service_call() to propagate errors
to guest by setting status codes or triggering program interrupts.
Signed-off-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Reviewed-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
dereg_irqs and dereg_ioat are needed by external functions. Let's
rename and export both of them in s390-pci-inst.h.
Signed-off-by: Yi Min Zhao <zyimin@linux.vnet.ibm.com>
Reviewed-by: Pierre Morel <pmorel@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Access register mode is one of the modes that control dynamic address
translation. In this mode the address space is specified by values of
the access registers. The effective address-space-control element is
obtained from the result of the access register translation. See
the "Access-Register Introduction" section of the chapter 5 "Program
Execution" in "Principles of Operations" for more details.
When the CPU is in AR mode, the s390_cpu_virt_mem_rw() function must
know which access register number to use for address translation.
This patch does several things:
- add new parameter 'uint8_t ar' to that function
- decode ar number from intercepted instructions
- pass the ar number to s390_cpu_virt_mem_rw(), which in turn passes it
to the KVM_S390_MEM_OP ioctl.
Signed-off-by: Alexander Yarygin <yarygin@linux.vnet.ibm.com>
Reviewed-by: Thomas Huth <thuth@linux.vnet.ibm.com>
Reviewed-by: David Hildenbrand <dahi@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
This patch implements the s390 pci instructions in qemu. It allows
to access and drive pci devices attached to the s390 pci bus.
Because of platform constrains devices using IO BARs are not
supported. Also a device has to support MSI/MSI-X to run on s390.
Signed-off-by: Frank Blaschka <frank.blaschka@de.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>