In my "build everything" tree, a change to the types in
qapi-schema.json triggers a recompile of about 4800 out of 5100
objects.
The previous commit split up qmp-commands.h, qmp-event.h, qmp-visit.h,
qapi-types.h. Each of these headers still includes all its shards.
Reduce compile time by including just the shards we actually need.
To illustrate the benefits: adding a type to qapi/migration.json now
recompiles some 2300 instead of 4800 objects. The next commit will
improve it further.
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Message-Id: <20180211093607.27351-24-armbru@redhat.com>
Reviewed-by: Eric Blake <eblake@redhat.com>
Reviewed-by: Marc-André Lureau <marcandre.lureau@redhat.com>
[eblake: rebase to master]
Signed-off-by: Eric Blake <eblake@redhat.com>
This patch is a follow up on the discussions made in patch
"hw/ppc: disable hotplug before CAS is completed" that can be
found at [1].
At this moment, we do not support CPU/memory hotplug in early
boot stages, before CAS. When a hotplug occurs, the event is logged
in an internal RTAS event log queue and an IRQ pulse is fired. In
regular conditions, the guest handles the interrupt by executing
check_exception, fetching the generated hotplug event and enabling
the device for use.
In early boot, this IRQ isn't caught (SLOF does not handle hotplug
events), leaving the event in the rtas event log queue. If the guest
executes check_exception due to another hotplug event, the re-assertion
of the IRQ ends up de-queuing the first hotplug event as well. In short,
a device hotplugged before CAS is considered coldplugged by SLOF.
This leads to device misbehavior and, in some cases, guest kernel
Ooops when trying to unplug the device.
A proper fix would be to turn every device hotplugged before CAS
as a colplugged device. This is not trivial to do with the current
code base though - the FDT is written in the guest memory at
ppc_spapr_reset and can't be retrieved without adding extra state
(fdt_size for example) that will need to managed and migrated. Adding
the hotplugged DT in the middle of CAS negotiation via the updated DT
tree works with CPU devs, but panics the guest kernel at boot. Additional
analysis would be necessary for LMBs and PCI devices. There are
questions to be made in QEMU/SLOF/kernel level about how we can make
this change in a sustainable way.
With Linux guests, a fix would be the kernel executing check_exception
at boot time, de-queueing the events that happened in early boot and
processing them. However, even if/when the newer kernels start
fetching these events at boot time, we need to take care of older
kernels that won't be doing that.
This patch works around the situation by issuing a CAS reset if a hotplugged
device is detected during CAS:
- the DRC conditions that warrant a CAS reset is the same as those that
triggers a DRC migration - the DRC must have a device attached and
the DRC state is not equal to its ready_state. With that in mind, this
patch makes use of 'spapr_drc_needed' to determine if a CAS reset
is needed.
- In the middle of CAS negotiations, the function
'spapr_hotplugged_dev_before_cas' goes through all the DRCs to see
if there are any DRC that requires a reset, using spapr_drc_needed. If
that happens, returns '1' in 'spapr_h_cas_compose_response' which will set
spapr->cas_reboot to true, causing the machine to reboot.
No changes are made for coldplug devices.
[1] http://lists.nongnu.org/archive/html/qemu-devel/2017-08/msg02855.html
Signed-off-by: Daniel Henrique Barboza <danielhb@linux.vnet.ibm.com>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
According to PAPR, the DR-indicator should only be valid for physical DRCs,
not logical DRCs. At the moment we implement it for all DRCs, so restrict
it to physical ones only.
We move the state to the physical DRC subclass, which means adding some
QOM boilerplate to handle the newly distinct type.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Most of the time, the state of a DRC object is contained in the single
'state' variable. However, during the transition from UNISOLATE to
CONFIGURED state requires multiple calls to the ibm,configure-connector
RTAS call to retrieve the device tree for the attached device. We need
some extra state to keep track of where we're up to in delivering the
device tree information to the guest.
Currently that extra state is in a sPAPRConfigureConnectorState
substructure which is only allocated when we're in the middle of the
configure connector process. That sounds like a good idea, but the extra
state is only two integers - on many platforms that will take up the same
room as the (maybe NULL) ccs pointer even before malloc() overhead. Plus
it's another object whose lifetime we need to manage. In short, it's not
worth it.
So, fold the sPAPRConfigureConnectorState substructure directly into the
DRC object.
Previously the structure was allocated lazily when the configure-connector
call discovers it's not there. Now, we need to initialize the subfields
pre-emptively, as soon as we enter UNISOLATE state.
Although it's not strictly necessary (the field values should only ever
be consulted when in UNISOLATE state), we try to keep them at -1 when in
other states, as a debugging aid.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Each DRC has three fields describing its state: isolation_state,
allocation_state and configured. At first this seems like a reasonable
representation, since its based directly on the PAPR defined
isolation-state and allocation-state indicators. However:
* Only a few combinations of the two fields' values are permitted
* allocation_state isn't used at all for physical DRCs
* The indicators are write only so they don't really have a well
defined current value independent of each other
This replaces these variables with a single state variable, whose names
and numbers are based on the diagram in LoPAPR section 13.4. Along with
this we add code to check the current state on various operations and make
sure the requested transition is permitted.
Strictly speaking, this makes guest visible changes to behaviour (since we
probably allowed some transitions we shouldn't have before). However, a
hypothetical guest broken by that wasn't PAPR compliant, and probably
wouldn't have worked under PowerVM.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
'awaiting_release' indicates that the host has requested an unplug of the
device attached to the DRC, but the guest has not (yet) put the device
into a state where it is safe to complete removal.
1. Rename it to 'unplug_requested' which to me at least is clearer
2. Remove the ->release_pending() method used to check this from outside
spapr_drc.c. The method only plausibly has one implementation, so use
a plain function (spapr_drc_unplug_requested()) instead.
3. Remove it from the migration stream. Attempting to migrate mid-unplug
is broken not just for spapr - in general management has no good way to
determine if the device should be present on the destination or not. So,
until that's fixed, there's no point adding extra things to the stream.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
This function has two unused parameters - remove them.
It also sets awaiting_release on all paths, except one. On that path
setting it is harmless, since it will be immediately cleared by
spapr_drc_release(). So factor it out of the if statements.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
The awaiting_allocation flag in the DRC was introduced by aab9913
"spapr_drc: Prevent detach racing against attach for CPU DR", allegedly to
prevent a guest crash on racing attach and detach. Except.. information
from the BZ actually suggests a qemu crash, not a guest crash. And there
shouldn't be a problem here anyway: if the guest has already moved the DRC
away from UNUSABLE state, the detach would already be deferred, and if it
hadn't it should be safe to detach it (the guest should fail gracefully
when it attempts to change the allocation state).
I think this was probably just a bandaid for some other problem in the
state management. So, remove awaiting_allocation and associated code.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
When migrating a guest which has already had devices hotplugged,
libvirt typically starts the destination qemu with -incoming defer,
adds those hotplugged devices with qmp, then initiates the incoming
migration.
This causes problems for the management of spapr DRC state. Because
the device is treated as hotplugged, it goes into a DRC state for a
device immediately after it's plugged, but before the guest has
acknowledged its presence. However, chances are the guest on the
source machine *has* acknowledged the device's presence and configured
it.
If the source has fully configured the device, then DRC state won't be
sent in the migration stream: for maximum migration compatibility with
earlier versions we don't migrate DRCs in coldplug-equivalent state.
That means that the DRC effectively changes state over the migrate,
causing problems later on.
In addition, logging hotplug events for these devices isn't what we
want because a) those events should already have been issued on the
source host and b) the event queue should get wiped out by the
incoming state anyway.
In short, what we really want is to treat devices added before an
incoming migration as if they were coldplugged.
To do this, we first add a spapr_drc_hotplugged() helper which
determines if the device is hotplugged in the sense relevant for DRC
state management. We only send hotplug events when this is true.
Second, when we add a device which isn't hotplugged in this sense, we
force a reset of the DRC state - this ensures the DRC is in a
coldplug-equivalent state (there isn't usually a system reset between
these device adds and the incoming migration).
This is based on an earlier patch by Laurent Vivier, cleaned up and
extended.
Signed-off-by: Laurent Vivier <lvivier@redhat.com>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
spapr_drc_attach() has a 'coldplug' parameter which sets the DRC into
configured state initially, instead of the usual ISOLATED/UNUSABLE state.
It turns out this is unnecessary: although coldplugged devices do need to
be in CONFIGURED state once the guest starts, that will already be
accomplished by the reset code which will move DRCs for already plugged
devices into a coldplug equivalent state.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
At the moment, spapr_drc_release() has an ugly switch on the DRC type to
call the right, device-specific release function. This cleans it up by
doing that via a proper QOM method.
It's still arguably an abstraction violation for the DRC code to call into
the specific device code, but one mess at a time.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
There are substantial differences in the various paths through
set_isolation_state(), both for setting to ISOLATED versus UNISOLATED
state and for logical versus physical DRCs.
So, split the set_isolation_state() method into isolate() and unisolate()
methods, and give it different implementations for the two DRC types.
Factor some minimal common checks, including for valid indicator values
(which we weren't previously checking) into rtas_set_isolation_state().
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
The allocation-state indicator should only actually be implemented for
"logical" DRCs, not physical ones. Factor a check for this, and also for
valid indicator state values into rtas_set_allocation_state(). Because
they don't exist for physical DRCs, there's no reason that we'd ever want
more than one method implementation, so it can just be a plain function.
In addition, the setting to USABLE and setting to UNUSABLE paths in
set_allocation_state() don't actually have much in common. So, split the
method separate functions for each parameter value (drc_set_usable()
and drc_set_unusable()).
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
The 'signalled' field in the DRC appears to be entirely a torturous
workaround for the fact that PCI devices were started in UNISOLATED state
for unclear reasons.
1) 'signalled' is already meaningless for logical (so far, all non PCI)
DRCs. It's always set to true (at least at any point it might be tested),
and can't be assigned any real meaning due to the way signalling works for
logical DRCs.
2) For PCI DRCs, the only time signalled would be false is when non-zero
functions of a multifunction device are hotplugged, followed by function
zero (the other way around is explicitly not permitted). In that case the
secondary function DRCs are attached, but the notification isn't sent to
the guest until function 0 is plugged.
3) signalled being false is used to allow a DRC detach to switch mode
back to ISOLATED state, which allows a secondary function to be hotplugged
then unplugged with function 0 never inserted. Without this a secondary
function starting in UNISOLATED state couldn't be detached again without
function 0 being inserted, all the functions configured by the guest, then
sent back to ISOLATED state.
4) But now that PCI DRCs start in ISOLATED state, there's nothing to be
done. If the guest doesn't get the notification, it won't switch the
device to UNISOLATED state, so nothing prevents it from being unplugged.
If the guest does move it to UNISOLATED state without the signal (due to
a manual drmgr call, for instance) then it really isn't safe to unplug it.
So, this patch removes the signalled variable and all code related to it.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Greg Kurz <groug@kaod.org>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
This reverts commit fe6824d126.
Conflicts hw/ppc/spapr_drc.c, because get_index() has been renamed
spapr_get_index().
This didn't fix the problem. Once the hotplug has been started
some memory is allocated and some structures are allocated.
We don't free it when we ignore the unplug, and we can't because
they can be in use by the kernel.
Signed-off-by: Laurent Vivier <lvivier@redhat.com>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
DRC objects have a get_name method which returns the DRC name generated
when the DRC is created. Replace that with a fixed spapr_drc_name()
function which generates the name on the fly from other information. This
means:
* We get rid of a method with only one implementation, and only local
callers
* We don't have to carry the name string around for the lifetime of the
DRC
* We use information added to the class structure to generate the name
in standard format, so we don't need an explicit switch on drc type
any more
We also eliminate the 'name' property; it's basically useless since the
only information in it can easily be deduced from other things.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
DRC objects have attach & detach methods, but there's only one
implementation. Although there are some differences in its behaviour for
different DRC types, the overall structure is the same, so while we might
want different method implementations for some parts, we're unlikely to
want them for the top-level functions.
So, replace them with direct function calls.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
There are 3 types of "indicator" associated with hotplug in the PAPR spec
the "allocation state", "isolation state" and "DR-indicator". The first
two are intimately tied to the various state transitions associated with
hotplug. The DR-indicator, however, is different and simpler.
It's basically just a guest controlled variable which can be used by the
guest to flag state or problems associated with a device. The idea is that
the hypervisor can use it to present information back on management
consoles (on some machines with PowerVM it may even control physical LEDs
on the machine case associated with the relevant device).
For that reason, there's only ever likely to be a single update
implementation so the set_indicator_state method isn't useful. Replace it
with a direct function call.
While we're there, make some small associated cleanups:
* PAPR doesn't use the term "indicator state", just "DR-indicator" and
the allocation state and isolation state are also considered "indicators".
Rename things to be less confusing
* Fold set_indicator_state() and rtas_set_indicator_state() into a single
rtas_set_dr_indicator() function.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
DRC classes have an entity_sense method to determine (in a specific PAPR
sense) the presence or absence of a device plugged into a DRC. However,
we only have one implementation of the method, which explicitly tests for
different DRC types. This changes it to instead have different method
implementations for the two cases: "logical" and "physical" DRCs.
While we're at it, the entity sense method always returns RTAS_OUT_SUCCESS,
and the interesting value is returned via pass-by-reference. Simplify this
to directly return the value we care about
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
This function was used in generating the device tree. However, now that
we have different QOM types for different DRC types we can easily store
the information we need in the class structure and avoid this specialized
lookup function.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Currently the sPAPRMachineState contains a list of sPAPRConfigureConnector
structures which store intermediate state for the ibm,configure-connector
RTAS call.
This was an attempt to separate this state from the core of the DRC state.
However the configure connector process is intimately tied to the DRC
model, so there's really no point trying to have two levels of interface
here.
Moving the configure-connector state into its corresponding DRC allows
removal of a number of helpers for maintaining the anciliary list.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
* Change names to something less ludicrously verbose
* Now that we have QOM subclasses for the different DRC types, use a QOM
typename instead of a PAPR type value parameter
The latter allows removal of the get_type_shift() helper.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Currently we only have a single QOM type for all DRCs, but lots of
places where we switch behaviour based on the DRC's PAPR defined type.
This is a poor use of our existing type system.
So, instead create QOM subclasses for each PAPR defined DRC type. We
also introduce intermediate subclasses for physical and logical DRCs,
a division which will be useful later on.
Instead of being stored in the DRC object itself, the PAPR type is now
stored in the class structure. There are still many places where we
switch directly on the PAPR type value, but this at least provides the
basis to start to remove those.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Acked-by: Michael Roth <mdroth@linux.vnet.ibm.com>
These two methods only have one implementation, and the spec they're
implementing means any other implementation is unlikely, verging on
impossible.
So replace them with simple functions.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
DRConnectorClass has a set_configured method, however:
* There is only one implementation, and only ever likely to be one
* There's exactly one caller, and that's (now) local
* The implementation is very straightforward
So abolish the method entirely, and just open-code what we need.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
The DRConnectorClass includes a get_fdt method. However
* There's only one implementation, and there's only likely to ever be one
* Both callers are local to spapr_drc
* Each caller only uses one half of the actual implementation
So abolish get_fdt() entirely, and just open-code what we need.
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reviewed-by: Laurent Vivier <lvivier@redhat.com>
Reviewed-by: Greg Kurz <groug@kaod.org>
Tested-by: Daniel Barboza <danielhb@linux.vnet.ibm.com>
The pointer drc->detach_cb is being used as a way of informing
the detach() function inside spapr_drc.c which cb to execute. This
information can also be retrieved simply by checking drc->type and
choosing the right callback based on it. In this context, detach_cb
is redundant information that must be managed.
After the previous spapr_lmb_release change, no detach_cb_opaques
are being used by any of the three callbacks functions. This is
yet another information that is now unused and, on top of that, can't
be migrated either.
This patch makes the following changes:
- removal of detach_cb_opaque. the 'opaque' argument was removed from
the callbacks and from the detach() function of sPAPRConnectorClass. The
attribute detach_cb_opaque of sPAPRConnector was removed.
- removal of detach_cb from the detach() call. The function pointer
detach_cb of sPAPRConnector was removed. detach() now uses a
switch(drc->type) to execute the apropriate callback. To achieve this,
spapr_core_release, spapr_lmb_release and spapr_phb_remove_pci_device_cb
callbacks were made public to be visible inside detach().
Signed-off-by: Daniel Henrique Barboza <danielhb@linux.vnet.ibm.com>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
If, once the kernel has booted, we try to remove a memory
hotplugged while the kernel was not started, QEMU crashes on
an assert:
qemu-system-ppc64: hw/virtio/vhost.c:651:
vhost_commit: Assertion `r >= 0' failed.
...
#4 in vhost_commit
#5 in memory_region_transaction_commit
#6 in pc_dimm_memory_unplug
#7 in spapr_memory_unplug
#8 spapr_machine_device_unplug
#9 in hotplug_handler_unplug
#10 in spapr_lmb_release
#11 in detach
#12 in set_allocation_state
#13 in rtas_set_indicator
...
If we take a closer look to the guest kernel log, we can see when
we try to unplug the memory:
pseries-hotplug-mem: Attempting to hot-add 4 LMB(s)
What happens:
1- The kernel has ignored the memory hotplug event because
it was not started when it was generated.
2- When we hot-unplug the memory,
QEMU starts to remove the memory,
generates an hot-unplug event,
and signals the kernel of the incoming new event
3- as the kernel is started, on the QEMU signal, it reads
the event list, decodes the hotplug event and tries to
finish the hotplugging.
4- QEMU receive the the hotplug notification while it
is trying to hot-unplug the memory. This moves the memory
DRC to an invalid state
This patch prevents this by not allowing to set the allocation
state to USABLE while the DRC is awaiting release.
RHBZ: https://bugzilla.redhat.com/show_bug.cgi?id=1432382
Signed-off-by: Laurent Vivier <lvivier@redhat.com>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Tracked down with an ugly, brittle and probably buggy Perl script.
Also move includes converted to <...> up so they get included before
ours where that's obviously okay.
Signed-off-by: Markus Armbruster <armbru@redhat.com>
Reviewed-by: Eric Blake <eblake@redhat.com>
Tested-by: Eric Blake <eblake@redhat.com>
Reviewed-by: Richard Henderson <rth@twiddle.net>
If a CPU is hot removed while hotplug of the same is still in progress,
the guest crashes. Prevent this by ensuring that detach is done only
after attach has completed.
The existing code already prevents such race for PCI hotplug. However
given that CPU is a logical DR unlike PCI and starts with ISOLATED
state, we need a logic that works for CPU too.
Signed-off-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
Reviewed-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
[Don't set awaiting_attach for PCI devices]
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Currently spapr doesn't support "aborting" hotplug of PCI
devices by allowing device_del to immediately remove the
device if we haven't signalled the presence of the device
to the guest.
In the past this wasn't an issue, since we always immediately
signalled device attach and simply relied on full guest-aware
add->remove path for device removal. However, as of 788d259,
we now defer signalling for PCI functions until function 0
is attached, so now we need to deal with these "abort" operations
for cases where a user hotplugs a non-0 function, then opts to
remove it prior hotplugging function 0. Currently they'd have to
reboot before the unplug completed. PCIe multifunction hotplug
does not have this requirement however, so from a management
implementation perspective it would be good to address this within
the same release as 788d259.
We accomplish this by simply adding a 'signalled' flag to track
whether a device hotplug event has been sent to the guest. If it
hasn't, we allow immediate removal under the assumption that the
guest will not be using the device. Devices present at boot/reset
time are also assumed to be 'signalled'.
For CPU/memory/etc, signalling will still happen immediately
as part of device_add, so only PCI functions should be affected.
Cc: bharata@linux.vnet.ibm.com
Cc: david@gibson.dropbear.id.au
Cc: sbhat@linux.vnet.ibm.com
Cc: qemu-ppc@nongnu.org
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
[dwg: This fixes a regression where an incorrect hot-add of a non-zero
function can no longer be backed out until function 0 is added]
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Certain methods in sPAPRDRConnector objects are only ever called by
RTAS and in many cases are responsible for the logic that determines
the RTAS return codes.
Rather than having a level of indirection requiring RTAS code to
re-interpret return values from such methods to determine the
appropriate return code, just pass them through directly.
This requires changing method return types to uint32_t to match the
type of values currently passed to RTAS helpers.
In the case of read accesses like drc->entity_sense() where we weren't
previously reporting any errors, just the read value, we modify the
function to return RTAS return code, and pass the read value back via
reference.
Suggested-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
Suggested-by: David Gibson <david@gibson.dropbear.id.au>
Cc: Bharata B Rao <bharata@linux.vnet.ibm.com>
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
If drmgr is used in the guest to hotplug a device before a device_add
has been issued via the QEMU monitor, QEMU segfaults in configure_connector
call. This occurs due to accessing of NULL FDT which otherwise would have
been created and associated with the DRC during device_add command.
Check for NULL FDT and return failure from configure_connector call.
As per PAPR+, an error value of -9003 seems appropriate for this failure.
Signed-off-by: Bharata B Rao <bharata@linux.vnet.ibm.com>
Cc: Michael Roth <mdroth@linux.vnet.ibm.com>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
This function handles generation of ibm,drc-* array device tree
properties to describe DRC topology to guests. This will by used
by the guest to direct RTAS calls to manage any dynamic resources
we associate with a particular DR Connector as part of
hotplug/unplug.
Since general management of boot-time device trees are handled
outside of sPAPRDRConnector, we insert these values blindly given
an FDT and offset. A mask of sPAPRDRConnector types is given to
instruct us on what types of connectors entries should be generated
for, since descriptions for different connectors may live in
different parts of the device tree.
Based on code originally written by Nathan Fontenot.
Signed-off-by: Nathan Fontenot <nfont@linux.vnet.ibm.com>
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: Alexander Graf <agraf@suse.de>
This device emulates a firmware abstraction used by pSeries guests to
manage hotplug/dynamic-reconfiguration of host-bridges, PCI devices,
memory, and CPUs. It is conceptually similar to an SHPC device,
complete with LED indicators to identify individual slots to physical
physical users and indicate when it is safe to remove a device. In
some cases it is also used to manage virtualized resources, such a
memory, CPUs, and physical-host bridges, which in the case of pSeries
guests are virtualized resources where the physical components are
managed by the host.
Guests communicate with these DR Connectors using RTAS calls,
generally by addressing the unique DRC index associated with a
particular connector for a particular resource. For introspection
purposes we expose this state initially as QOM properties, and
in subsequent patches will introduce the RTAS calls that make use of
it. This constitutes to the 'guest' interface.
On the QEMU side we provide an attach/detach interface to associate
or cleanup a DeviceState with a particular sPAPRDRConnector in
response to hotplug/unplug, respectively. This constitutes the
'physical' interface to the DR Connector.
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: Alexander Graf <agraf@suse.de>