Format NVM admin command can make a namespace or namespaces to be
with different LBA size and metadata size with protection information
types.
This patch introduces Format NVM command with LBA format, Metadata, and
Protection Information for the device. The secure erase operation things
and support for formatting zoned namespaces are yet to be added.
The parameter checks inside of this patch has been referred from
Keith's old branch.
Signed-off-by: Minwoo Im <minwoo.im@samsung.com>
[anaidu.gollu: rebased on e2e]
Signed-off-by: Gollu Appalanaidu <anaidu.gollu@samsung.com>
[k.jensen: rebased for reworked aio tracking]
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
In preparation for Format NVM support, use runtime helpers instead of
the constant device parameters when getting lba size information etc.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Add support for namespaces formatted with protection information. The
type of end-to-end data protection (i.e. Type 1, Type 2 or Type 3) is
selected with the `pi` nvme-ns device parameter. If the number of
metadata bytes is larger than 8, the `pil` nvme-ns device parameter may
be used to control the location of the 8-byte DIF tuple. The default
`pil` value of '0', causes the DIF tuple to be transferred as the last
8 bytes of the metadata. Set to 1 to store this in the first eight bytes
instead.
Co-authored-by: Gollu Appalanaidu <anaidu.gollu@samsung.com>
Signed-off-by: Gollu Appalanaidu <anaidu.gollu@samsung.com>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Add support for metadata in the form of extended logical blocks as well
as a separate buffer of data. The new `ms` nvme-ns device parameter
specifies the size of metadata per logical block in bytes. The `mset`
nvme-ns device parameter controls whether metadata is transfered as part
of an extended lba (set to '1') or in a separate buffer (set to '0',
the default).
Regardsless of the scheme chosen with `mset`, metadata is stored at the
end of the namespace backing block device. This requires the user
provided PRP/SGLs to be walked and "split" into data and metadata
scatter/gather lists if the extended logical block scheme is used, but
has the advantage of not breaking the deallocated blocks support.
Co-authored-by: Gollu Appalanaidu <anaidu.gollu@samsung.com>
Signed-off-by: Gollu Appalanaidu <anaidu.gollu@samsung.com>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
If namespace inventory is changed due to some reasons (e.g., namespace
attachment/detachment), controller can send out event notifier to the
host to manage namespaces.
This patch sends out the AEN to the host after either attach or detach
namespaces from controllers. To support clear of the event from the
controller, this patch also implemented Get Log Page command for Changed
Namespace List log type. To return namespace id list through the
command, when namespace inventory is updated, id is added to the
per-controller list (changed_ns_list).
To indicate the support of this async event, this patch set
OAES(Optional Asynchronous Events Supported) in Identify Controller data
structure.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Tested-by: Klaus Jensen <k.jensen@samsung.com>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Given that now we have nvme-subsys device supported, we can manage
namespace allocated, but not attached: detached. This patch introduced
a parameter for nvme-ns device named 'detached'. This parameter
indicates whether the given namespace device is detached from
a entire NVMe subsystem('subsys' given case, shared namespace) or a
controller('bus' given case, private namespace).
- Allocated namespace
1) Shared ns in the subsystem 'subsys0':
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,subsys=subsys0,detached=true
2) Private ns for the controller 'nvme0' of the subsystem 'subsys0':
-device nvme-subsys,id=subsys0
-device nvme,serial=foo,id=nvme0,subsys=subsys0
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,bus=nvme0,detached=true
3) (Invalid case) Controller 'nvme0' has no subsystem to manage ns:
-device nvme,serial=foo,id=nvme0
-device nvme-ns,id=ns1,drive=blknvme0,nsid=1,bus=nvme0,detached=true
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Add support for TP 4065a ("Simple Copy Command"), v2020.05.04
("Ratified").
The implementation uses a bounce buffer to first read in the source
logical blocks, then issue a write of that bounce buffer. The default
maximum number of source logical blocks is 128, translating to 512 KiB
for 4k logical blocks which aligns with the default value of MDTS.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
nvme-ns device is registered to a nvme controller device during the
initialization in nvme_register_namespace() in case that 'bus' property
is given which means it's mapped to a single controller.
This patch introduced a new property 'subsys' just like the controller
device instance did to map a namespace to a NVMe subsystem.
If 'subsys' property is given to the nvme-ns device, it will belong to
the specified subsystem and will be attached to all controllers in that
subsystem by enabling shared namespace capability in NMIC(Namespace
Multi-path I/O and Namespace Capabilities) in Identify Namespace.
Usage:
-device nvme-subsys,id=subsys0
-device nvme,serial=foo,id=nvme0,subsys=subsys0
-device nvme,serial=bar,id=nvme1,subsys=subsys0
-device nvme,serial=baz,id=nvme2,subsys=subsys0
-device nvme-ns,id=ns1,drive=<drv>,nsid=1,subsys=subsys0 # Shared
-device nvme-ns,id=ns2,drive=<drv>,nsid=2,bus=nvme2 # Non-shared
In the above example, 'ns1' will be shared to 'nvme0' and 'nvme1' in
the same subsystem. On the other hand, 'ns2' will be attached to the
'nvme2' only as a private namespace in that subsystem.
All the namespace with 'subsys' parameter will attach all controllers in
the subsystem to the namespace by default.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Tested-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
nvme_ns_setup() finally does not have nothing to do with NvmeCtrl
instance.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Align with existing style and use a typedef for header-file enums.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Tested-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Zone Descriptor Extension is a label that can be assigned to a zone.
It can be set to an Empty zone and it stays assigned until the zone
is reset.
This commit adds a new optional module property,
"zoned.descr_ext_size". Its value must be a multiple of 64 bytes.
If this value is non-zero, it becomes possible to assign extensions
of that size to any Empty zones. The default value for this property
is 0, therefore setting extensions is disabled by default.
Signed-off-by: Hans Holmberg <hans.holmberg@wdc.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Add two module properties, "zoned.max_active" and "zoned.max_open"
to control the maximum number of zones that can be active or open.
Once these variables are set to non-default values, these limits are
checked during I/O and Too Many Active or Too Many Open command status
is returned if they are exceeded.
Signed-off-by: Hans Holmberg <hans.holmberg@wdc.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
The emulation code has been changed to advertise NVM Command Set when
"zoned" device property is not set (default) and Zoned Namespace
Command Set otherwise.
Define values and structures that are needed to support Zoned
Namespace Command Set (NVMe TP 4053) in PCI NVMe controller emulator.
Define trace events where needed in newly introduced code.
In order to improve scalability, all open, closed and full zones
are organized in separate linked lists. Consequently, almost all
zone operations don't require scanning of the entire zone array
(which potentially can be quite large) - it is only necessary to
enumerate one or more zone lists.
Handlers for three new NVMe commands introduced in Zoned Namespace
Command Set specification are added, namely for Zone Management
Receive, Zone Management Send and Zone Append.
Device initialization code has been extended to create a proper
configuration for zoned operation using device properties.
Read/Write command handler is modified to only allow writes at the
write pointer if the namespace is zoned. For Zone Append command,
writes implicitly happen at the write pointer and the starting write
pointer value is returned as the result of the command. Write Zeroes
handler is modified to add zoned checks that are identical to those
done as a part of Write flow.
Subsequent commits in this series add ZDE support and checks for
active and open zone limits.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Hans Holmberg <hans.holmberg@wdc.com>
Signed-off-by: Ajay Joshi <ajay.joshi@wdc.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Matias Bjorling <matias.bjorling@wdc.com>
Signed-off-by: Aravind Ramesh <aravind.ramesh@wdc.com>
Signed-off-by: Shin'ichiro Kawasaki <shinichiro.kawasaki@wdc.com>
Signed-off-by: Adam Manzanares <adam.manzanares@wdc.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Define the structures and constants required to implement
Namespace Types support.
Namespace Types introduce a new command set, "I/O Command Sets",
that allows the host to retrieve the command sets associated with
a namespace. Introduce support for the command set and enable
detection for the NVM Command Set.
The new workflows for identify commands rely heavily on zero-filled
identify structs. E.g., certain CNS commands are defined to return
a zero-filled identify struct when an inactive namespace NSID
is supplied.
Add a helper function in order to avoid code duplication when
reporting zero-filled identify structures.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
This log page becomes necessary to implement to allow checking for
Zone Append command support in Zoned Namespace Command Set.
This commit adds the code to report this log page for NVM Command
Set only. The parts that are specific to zoned operation will be
added later in the series.
All incoming admin and i/o commands are now only processed if their
corresponding support bits are set in this log. This provides an
easy way to control what commands to support and what not to
depending on set CC.CSS.
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
In NVMe 1.4, a namespace must report an ID descriptor of UUID type
if it doesn't support EUI64 or NGUID. Add a new namespace property,
"uuid", that provides the user the option to either specify the UUID
explicitly or have a UUID generated automatically every time a
namespace is initialized.
Suggested-by: Klaus Jensen <k.jensen@samsung.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Niklas Cassel <Niklas.Cassel@wdc.com>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Controller reset ans subsystem shutdown are handled very much the same
in the current code, but some of the steps should be different in these
two cases.
Introduce two new functions, nvme_reset_ctrl() and nvme_shutdown_ctrl(),
to separate some portions of the code from nvme_clear_ctrl(). The steps
that are made different between reset and shutdown are that BAR.CC is not
reset to zero upon the shutdown and namespace data is flushed to
backing storage as a part of shutdown handling, but not upon reset.
Suggested-by: Klaus Jensen <k.jensen@samsung.com>
Signed-off-by: Dmitry Fomichev <dmitry.fomichev@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Add support for reporting the Deallocated or Unwritten Logical Block
Error (DULBE).
Rely on the block status flags reported by the block layer and consider
any block with the BDRV_BLOCK_ZERO flag to be deallocated.
Multiple factors affect when a Write Zeroes command result in
deallocation of blocks.
* the underlying file system block size
* the blockdev format
* the 'discard' and 'logical_block_size' parameters
format | discard | wz (512B) wz (4KiB) wz (64KiB)
-----------------------------------------------------
qcow2 ignore n n y
qcow2 unmap n n y
raw ignore n y y
raw unmap n y y
So, this works best with an image in raw format and 4KiB LBAs, since
holes can then be punched on a per-block basis (this assumes a file
system with a 4kb block size, YMMV). A qcow2 image, uses a cluster size
of 64KiB by default and blocks will only be marked deallocated if a full
cluster is zeroed or discarded. However, this *is* consistent with the
spec since Write Zeroes "should" deallocate the block if the Deallocate
attribute is set and "may" deallocate if the Deallocate attribute is not
set. Thus, we always try to deallocate (the BDRV_REQ_MAY_UNMAP flag is
always set).
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
This adds support for multiple namespaces by introducing a new 'nvme-ns'
device model. The nvme device creates a bus named from the device name
('id'). The nvme-ns devices then connect to this and registers
themselves with the nvme device.
This changes how an nvme device is created. Example with two namespaces:
-drive file=nvme0n1.img,if=none,id=disk1
-drive file=nvme0n2.img,if=none,id=disk2
-device nvme,serial=deadbeef,id=nvme0
-device nvme-ns,drive=disk1,bus=nvme0,nsid=1
-device nvme-ns,drive=disk2,bus=nvme0,nsid=2
The drive property is kept on the nvme device to keep the change
backward compatible, but the property is now optional. Specifying a
drive for the nvme device will always create the namespace with nsid 1.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>