The PSI bridge on POWER9 is very similar to POWER8. The BAR is still
set through XSCOM but the controls are now entirely done with MMIOs.
More interrupts are defined and the interrupt controller interface has
changed to XIVE. The POWER9 model is a first example of the usage of
the notify() handler of the XiveNotifier interface, linking the PSI
XiveSource to its owning device model.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20190307223548.20516-3-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
To ease the introduction of the PSI bridge model for POWER9, abstract
the POWER chip differences in a PnvPsi class model and introduce a
specific Pnv8Psi type for POWER8. POWER8 interface to the interrupt
controller is still XICS whereas POWER9 uses the new XIVE model.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20190307223548.20516-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Reset all regs but keep the MMIO BAR enabled as it is at realize time.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20190306085032.15744-14-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
This is a simple helper to translate XSCOM addresses to MMIO addresses
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20190306085032.15744-13-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Both functions, object_initialize() and object_property_add_child() increase
the reference counter of the new object, so one of the references has to be
dropped afterwards to get the reference counting right. Otherwise the child
object will not be properly cleaned up when the parent gets destroyed.
Thus let's use now object_initialize_child() instead to get the reference
counting here right.
Suggested-by: Eduardo Habkost <ehabkost@redhat.com>
Signed-off-by: Thomas Huth <thuth@redhat.com>
Message-Id: <1550748288-30598-1-git-send-email-thuth@redhat.com>
Reviewed-by: Cédric Le Goater <clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
Future changes of the ICSState object will remove the qemu_irq array
from under the interrupt controller model. Prepare ground for the PSI
interrupt sources and introduce a new one directly under the PSI
device model.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
The 'pnv' prefix is now used for all and the routines populating the
device tree start with 'pnv_dt'. The handler of the PnvXScomInterface
is also renamed to 'dt_xscom' which should reflect that it is
populating the device tree under the 'xscom@' node of the chip.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
These properties are part of the XICS API. They deserve to appear
explicitely in the XICS header file.
Signed-off-by: Greg Kurz <groug@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
The Processor Service Interface (PSI) Controller is one of the engines
of the "Bridge" unit which connects the different interfaces to the
Power Processor.
This adds just enough of the PSI bridge to handle various on-chip and
the one external interrupt. The rest of PSI has to do with the link to
the IBM FSP service processor which we don't plan to emulate (not used
on OpenPower machines).
The ics_get() and ics_resend() handlers of the XICSFabric interface of
the PowerNV machine are now defined to handle the Interrupt Control
Source of PSI. The InterruptStatsProvider interface is also modified
to dump the new ICS.
Originally from Benjamin Herrenschmidt <benh@kernel.crashing.org>
Signed-off-by: Cédric Le Goater <clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>