Commit Graph

2 Commits

Author SHA1 Message Date
Guenter Roeck
3a0b75880a hw/sensor/tmp105: Lower 4 bit of limit registers are always 0
Per datasheet, "HIGH AND LOW LIMIT REGISTERS", the lower 4 bit
of the limit registers are unused and always report 0.
The lower 4 bit should not be used for temperature comparisons,
so mask the unused bits before storing the limits.

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Philippe Mathieu-Daudé <philmd@linaro.org>
Reviewed-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20240906154911.86803-6-philmd@linaro.org>
[PMD: Update tests/qtest/ files]
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
2024-09-13 20:11:13 +02:00
Rayhan Faizel
0820e097fa tests/qtest: Add testcase for BCM2835 BSC
Simple testcase for validating proper operation of read and write for all
three BSC controllers.

Signed-off-by: Rayhan Faizel <rayhan.faizel@gmail.com>
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Message-id: 20240224191038.2409945-4-rayhan.faizel@gmail.com
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
2024-03-05 13:22:55 +00:00