hw/misc/iotkit-secctl: Fix writing to 'PPC Interrupt Clear' register
Fix warning reported by Clang static code analyzer:
CC hw/misc/iotkit-secctl.o
hw/misc/iotkit-secctl.c:343:9: warning: Value stored to 'value' is never read
value &= 0x00f000f3;
^ ~~~~~~~~~~
Fixes: b3717c23e1
Reported-by: Clang Static Analyzer
Signed-off-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Message-id: 20200217132922.24607-1-f4bug@amsat.org
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
This commit is contained in:
parent
7ffe647f52
commit
9df7401b80
@ -340,7 +340,7 @@ static MemTxResult iotkit_secctl_s_write(void *opaque, hwaddr addr,
|
||||
qemu_set_irq(s->sec_resp_cfg, s->secrespcfg);
|
||||
break;
|
||||
case A_SECPPCINTCLR:
|
||||
value &= 0x00f000f3;
|
||||
s->secppcintstat &= ~(value & 0x00f000f3);
|
||||
foreach_ppc(s, iotkit_secctl_ppc_update_irq_clear);
|
||||
break;
|
||||