esp: apply transfer length adjustment when STC is zero at TC load time
Perform the length adjustment whereby a value of 0 in the STC represents a transfer length of 0x10000 at the point where the TC is loaded at the start of a DMA command rather than just when a TI (Transfer Information) command is executed. This better matches the description as given in the datasheet. Signed-off-by: Mark Cave-Ayland <mark.cave-ayland@ilande.co.uk> Reviewed-by: Laurent Vivier <laurent@vivier.eu> Message-Id: <20210304221103.6369-12-mark.cave-ayland@ilande.co.uk>
This commit is contained in:
parent
c04ed569b0
commit
96676c2f74
@ -561,9 +561,6 @@ static void handle_ti(ESPState *s)
|
||||
}
|
||||
|
||||
dmalen = esp_get_tc(s);
|
||||
if (dmalen == 0) {
|
||||
dmalen = 0x10000;
|
||||
}
|
||||
s->dma_counter = dmalen;
|
||||
|
||||
if (s->do_cmd) {
|
||||
@ -698,7 +695,11 @@ void esp_reg_write(ESPState *s, uint32_t saddr, uint64_t val)
|
||||
if (val & CMD_DMA) {
|
||||
s->dma = 1;
|
||||
/* Reload DMA counter. */
|
||||
esp_set_tc(s, esp_get_stc(s));
|
||||
if (esp_get_stc(s) == 0) {
|
||||
esp_set_tc(s, 0x10000);
|
||||
} else {
|
||||
esp_set_tc(s, esp_get_stc(s));
|
||||
}
|
||||
} else {
|
||||
s->dma = 0;
|
||||
}
|
||||
|
Loading…