cadence_uart: Check baud rate generator and divider values on migration
The Cadence UART device emulator calculates speed by dividing the baud rate by a 'baud rate generator' & 'baud rate divider' value. The device specification defines these register values to be non-zero and within certain limits. Checks were recently added when writing to these registers but not when restoring from migration. This patch adds checks when restoring from migration to avoid divide by zero errors. Reported-by: Huawei PSIRT <psirt@huawei.com> Signed-off-by: Alistair Francis <alistair.francis@xilinx.com> Message-id: 04ae30ed8ee1758cd2d2af880da4d28f74c67738.1481132150.git.alistair.francis@xilinx.com Reviewed-by: Peter Maydell <peter.maydell@linaro.org> Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
This commit is contained in:
parent
a470b33259
commit
450aaae863
@ -502,6 +502,13 @@ static int cadence_uart_post_load(void *opaque, int version_id)
|
||||
{
|
||||
CadenceUARTState *s = opaque;
|
||||
|
||||
/* Ensure these two aren't invalid numbers */
|
||||
if (s->r[R_BRGR] < 1 || s->r[R_BRGR] & ~0xFFFF ||
|
||||
s->r[R_BDIV] <= 3 || s->r[R_BDIV] & ~0xFF) {
|
||||
/* Value is invalid, abort */
|
||||
return 1;
|
||||
}
|
||||
|
||||
uart_parameters_setup(s);
|
||||
uart_update_status(s);
|
||||
return 0;
|
||||
|