Fix powerpc 604 reset vector
According to 604eUM_book (see 8.3.3 Reset inputs p8-54), the IP bit is set for hreset and the vector is at offset 0x100 from the exception prefix. No difference in this area between 604 and 604e. Signed-off-by: Tristan Gingold <gingold@adacore.com>
This commit is contained in:
parent
fc1c67bc2a
commit
2d3eb7bfd9
@ -2875,9 +2875,9 @@ static void init_excp_604 (CPUPPCState *env)
|
||||
env->excp_vectors[POWERPC_EXCP_PERFM] = 0x00000F00;
|
||||
env->excp_vectors[POWERPC_EXCP_IABR] = 0x00001300;
|
||||
env->excp_vectors[POWERPC_EXCP_SMI] = 0x00001400;
|
||||
env->hreset_excp_prefix = 0x00000000UL;
|
||||
env->hreset_excp_prefix = 0xFFF00000UL;
|
||||
/* Hardware reset vector */
|
||||
env->hreset_vector = 0xFFFFFFFCUL;
|
||||
env->hreset_vector = 0x00000100UL;
|
||||
#endif
|
||||
}
|
||||
|
||||
|
Loading…