73cdcdfe09
* Fixed remdesk settings pointer * Fixed sign warnings in display_write_monitor_layout_pdu * Use freerdp_abort_connect_context and freerdp_shall_disconnect_context * Added and updates settings * info assert/dynamic timezone * mcs assert/log/flags * Fixed and added assertions for wStream * Unified stream length checks * Added new function to check for lenght and log * Replace all usages with this new function * Cleaned up PER, added parser logging * Cleaned up BER, added parser logging * log messages * Modified Stream_CheckAndLogRequiredLengthEx * Allow custom format and options * Add Stream_CheckAndLogRequiredLengthExVa for prepared va_list * Improved Stream_CheckAndLogRequiredLength * Now have log level adjustable * Added function equivalents for existing logger * Added a backtrace in case of a failure is detected * Fixed public API input checks
1424 lines
37 KiB
C
1424 lines
37 KiB
C
/**
|
|
* FreeRDP: A Remote Desktop Protocol Implementation
|
|
* Remote Applications Integrated Locally (RAIL) Orders
|
|
*
|
|
* Copyright 2009 Marc-Andre Moreau <marcandre.moreau@gmail.com>
|
|
* Copyright 2011 Roman Barabanov <romanbarabanov@gmail.com>
|
|
* Copyright 2015 Thincast Technologies GmbH
|
|
* Copyright 2015 DI (FH) Martin Haimberger <martin.haimberger@thincast.com>
|
|
* Copyright 2017 Armin Novak <armin.novak@thincast.com>
|
|
* Copyright 2017 Thincast Technologies GmbH
|
|
*
|
|
* Licensed under the Apache License, Version 2.0 (the "License");
|
|
* you may not use this file except in compliance with the License.
|
|
* You may obtain a copy of the License at
|
|
*
|
|
* http://www.apache.org/licenses/LICENSE-2.0
|
|
*
|
|
* Unless required by applicable law or agreed to in writing, software
|
|
* distributed under the License is distributed on an "AS IS" BASIS,
|
|
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
* See the License for the specific language governing permissions and
|
|
* limitations under the License.
|
|
*/
|
|
|
|
#include <freerdp/config.h>
|
|
|
|
#include <winpr/crt.h>
|
|
|
|
#include <freerdp/channels/log.h>
|
|
|
|
#include "rail_orders.h"
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_pdu(railPlugin* rail, wStream* s, UINT16 orderType)
|
|
{
|
|
UINT16 orderLength;
|
|
|
|
if (!rail || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
orderLength = (UINT16)Stream_GetPosition(s);
|
|
Stream_SetPosition(s, 0);
|
|
rail_write_pdu_header(s, orderType, orderLength);
|
|
Stream_SetPosition(s, orderLength);
|
|
WLog_Print(rail->log, WLOG_DEBUG, "Sending %s PDU, length: %" PRIu16 "",
|
|
rail_get_order_type_string(orderType), orderLength);
|
|
return rail_send_channel_data(rail, s);
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_read_server_exec_result_order(wStream* s, RAIL_EXEC_RESULT_ORDER* execResult)
|
|
{
|
|
if (!s || !execResult)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_EXEC_RESULT_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT16(s, execResult->flags); /* flags (2 bytes) */
|
|
Stream_Read_UINT16(s, execResult->execResult); /* execResult (2 bytes) */
|
|
Stream_Read_UINT32(s, execResult->rawResult); /* rawResult (4 bytes) */
|
|
Stream_Seek_UINT16(s); /* padding (2 bytes) */
|
|
return rail_read_unicode_string(s, &execResult->exeOrFile)
|
|
? CHANNEL_RC_OK
|
|
: ERROR_INTERNAL_ERROR; /* exeOrFile */
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_read_server_minmaxinfo_order(wStream* s, RAIL_MINMAXINFO_ORDER* minmaxinfo)
|
|
{
|
|
if (!s || !minmaxinfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_MINMAXINFO_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, minmaxinfo->windowId); /* windowId (4 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxWidth); /* maxWidth (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxHeight); /* maxHeight (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxPosX); /* maxPosX (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxPosY); /* maxPosY (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->minTrackWidth); /* minTrackWidth (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->minTrackHeight); /* minTrackHeight (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxTrackWidth); /* maxTrackWidth (2 bytes) */
|
|
Stream_Read_INT16(s, minmaxinfo->maxTrackHeight); /* maxTrackHeight (2 bytes) */
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_read_server_localmovesize_order(wStream* s,
|
|
RAIL_LOCALMOVESIZE_ORDER* localMoveSize)
|
|
{
|
|
UINT16 isMoveSizeStart;
|
|
|
|
if (!s || !localMoveSize)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_LOCALMOVESIZE_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, localMoveSize->windowId); /* windowId (4 bytes) */
|
|
Stream_Read_UINT16(s, isMoveSizeStart); /* isMoveSizeStart (2 bytes) */
|
|
localMoveSize->isMoveSizeStart = (isMoveSizeStart != 0) ? TRUE : FALSE;
|
|
Stream_Read_UINT16(s, localMoveSize->moveSizeType); /* moveSizeType (2 bytes) */
|
|
Stream_Read_INT16(s, localMoveSize->posX); /* posX (2 bytes) */
|
|
Stream_Read_INT16(s, localMoveSize->posY); /* posY (2 bytes) */
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_read_server_get_appid_resp_order(wStream* s,
|
|
RAIL_GET_APPID_RESP_ORDER* getAppidResp)
|
|
{
|
|
if (!s || !getAppidResp)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_GET_APPID_RESP_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, getAppidResp->windowId); /* windowId (4 bytes) */
|
|
Stream_Read_UTF16_String(
|
|
s, getAppidResp->applicationId,
|
|
ARRAYSIZE(getAppidResp->applicationId)); /* applicationId (260 UNICODE chars) */
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_read_langbar_info_order(wStream* s, RAIL_LANGBAR_INFO_ORDER* langbarInfo)
|
|
{
|
|
if (!s || !langbarInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_LANGBAR_INFO_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, langbarInfo->languageBarStatus); /* languageBarStatus (4 bytes) */
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_write_client_status_order(wStream* s, const RAIL_CLIENT_STATUS_ORDER* clientStatus)
|
|
{
|
|
if (!s || !clientStatus)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, clientStatus->flags); /* flags (4 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_write_client_exec_order(wStream* s, UINT16 flags,
|
|
const RAIL_UNICODE_STRING* exeOrFile,
|
|
const RAIL_UNICODE_STRING* workingDir,
|
|
const RAIL_UNICODE_STRING* arguments)
|
|
{
|
|
UINT error;
|
|
|
|
if (!s || !exeOrFile || !workingDir || !arguments)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
/* [MS-RDPERP] 2.2.2.3.1 Client Execute PDU (TS_RAIL_ORDER_EXEC)
|
|
* Check argument limits */
|
|
if ((exeOrFile->length > 520) || (workingDir->length > 520) || (arguments->length > 16000))
|
|
{
|
|
WLog_ERR(TAG,
|
|
"TS_RAIL_ORDER_EXEC argument limits exceeded: ExeOrFile=%" PRIu16
|
|
" [max=520], WorkingDir=%" PRIu16 " [max=520], Arguments=%" PRIu16 " [max=16000]",
|
|
exeOrFile->length, workingDir->length, arguments->length);
|
|
return ERROR_BAD_ARGUMENTS;
|
|
}
|
|
|
|
Stream_Write_UINT16(s, flags); /* flags (2 bytes) */
|
|
Stream_Write_UINT16(s, exeOrFile->length); /* exeOrFileLength (2 bytes) */
|
|
Stream_Write_UINT16(s, workingDir->length); /* workingDirLength (2 bytes) */
|
|
Stream_Write_UINT16(s, arguments->length); /* argumentsLength (2 bytes) */
|
|
|
|
if ((error = rail_write_unicode_string_value(s, exeOrFile)))
|
|
{
|
|
WLog_ERR(TAG, "rail_write_unicode_string_value failed with error %" PRIu32 "", error);
|
|
return error;
|
|
}
|
|
|
|
if ((error = rail_write_unicode_string_value(s, workingDir)))
|
|
{
|
|
WLog_ERR(TAG, "rail_write_unicode_string_value failed with error %" PRIu32 "", error);
|
|
return error;
|
|
}
|
|
|
|
if ((error = rail_write_unicode_string_value(s, arguments)))
|
|
{
|
|
WLog_ERR(TAG, "rail_write_unicode_string_value failed with error %" PRIu32 "", error);
|
|
return error;
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_write_client_activate_order(wStream* s, const RAIL_ACTIVATE_ORDER* activate)
|
|
{
|
|
BYTE enabled;
|
|
|
|
if (!s || !activate)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, activate->windowId); /* windowId (4 bytes) */
|
|
enabled = activate->enabled ? 1 : 0;
|
|
Stream_Write_UINT8(s, enabled); /* enabled (1 byte) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_client_sysmenu_order(wStream* s, const RAIL_SYSMENU_ORDER* sysmenu)
|
|
{
|
|
if (!s || !sysmenu)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, sysmenu->windowId); /* windowId (4 bytes) */
|
|
Stream_Write_INT16(s, sysmenu->left); /* left (2 bytes) */
|
|
Stream_Write_INT16(s, sysmenu->top); /* top (2 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_client_syscommand_order(wStream* s, const RAIL_SYSCOMMAND_ORDER* syscommand)
|
|
{
|
|
if (!s || !syscommand)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, syscommand->windowId); /* windowId (4 bytes) */
|
|
Stream_Write_UINT16(s, syscommand->command); /* command (2 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_client_notify_event_order(wStream* s,
|
|
const RAIL_NOTIFY_EVENT_ORDER* notifyEvent)
|
|
{
|
|
if (!s || !notifyEvent)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, notifyEvent->windowId); /* windowId (4 bytes) */
|
|
Stream_Write_UINT32(s, notifyEvent->notifyIconId); /* notifyIconId (4 bytes) */
|
|
Stream_Write_UINT32(s, notifyEvent->message); /* notifyIconId (4 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_client_window_move_order(wStream* s,
|
|
const RAIL_WINDOW_MOVE_ORDER* windowMove)
|
|
{
|
|
if (!s || !windowMove)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, windowMove->windowId); /* windowId (4 bytes) */
|
|
Stream_Write_INT16(s, windowMove->left); /* left (2 bytes) */
|
|
Stream_Write_INT16(s, windowMove->top); /* top (2 bytes) */
|
|
Stream_Write_INT16(s, windowMove->right); /* right (2 bytes) */
|
|
Stream_Write_INT16(s, windowMove->bottom); /* bottom (2 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_client_get_appid_req_order(wStream* s,
|
|
const RAIL_GET_APPID_REQ_ORDER* getAppidReq)
|
|
{
|
|
if (!s || !getAppidReq)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, getAppidReq->windowId); /* windowId (4 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_langbar_info_order(wStream* s, const RAIL_LANGBAR_INFO_ORDER* langbarInfo)
|
|
{
|
|
if (!s || !langbarInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, langbarInfo->languageBarStatus); /* languageBarStatus (4 bytes) */
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_languageime_info_order(wStream* s,
|
|
const RAIL_LANGUAGEIME_INFO_ORDER* langImeInfo)
|
|
{
|
|
if (!s || !langImeInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, langImeInfo->ProfileType);
|
|
Stream_Write_UINT16(s, langImeInfo->LanguageID);
|
|
Stream_Write(s, &langImeInfo->LanguageProfileCLSID, sizeof(langImeInfo->LanguageProfileCLSID));
|
|
Stream_Write(s, &langImeInfo->ProfileGUID, sizeof(langImeInfo->ProfileGUID));
|
|
Stream_Write_UINT32(s, langImeInfo->KeyboardLayout);
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
static UINT rail_write_compartment_info_order(wStream* s,
|
|
const RAIL_COMPARTMENT_INFO_ORDER* compartmentInfo)
|
|
{
|
|
if (!s || !compartmentInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
Stream_Write_UINT32(s, compartmentInfo->ImeState);
|
|
Stream_Write_UINT32(s, compartmentInfo->ImeConvMode);
|
|
Stream_Write_UINT32(s, compartmentInfo->ImeSentenceMode);
|
|
Stream_Write_UINT32(s, compartmentInfo->KanaMode);
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_handshake_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_HANDSHAKE_ORDER serverHandshake = { 0 };
|
|
UINT error;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_handshake_order(s, &serverHandshake)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_handshake_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
rail->channelBuildNumber = serverHandshake.buildNumber;
|
|
|
|
if (rail->sendHandshake)
|
|
{
|
|
RAIL_HANDSHAKE_ORDER clientHandshake = { 0 };
|
|
clientHandshake.buildNumber = 0x00001DB0;
|
|
error = context->ClientHandshake(context, &clientHandshake);
|
|
}
|
|
|
|
if (error != CHANNEL_RC_OK)
|
|
return error;
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerHandshake, error, context, &serverHandshake);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerHandshake failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static BOOL rail_is_feature_supported(const rdpContext* context, UINT32 featureMask)
|
|
{
|
|
UINT32 supported, masked;
|
|
|
|
if (!context || !context->settings)
|
|
return FALSE;
|
|
|
|
supported = context->settings->RemoteApplicationSupportLevel &
|
|
context->settings->RemoteApplicationSupportMask;
|
|
masked = (supported & featureMask);
|
|
|
|
if (masked != featureMask)
|
|
return FALSE;
|
|
|
|
return TRUE;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_handshake_ex_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_HANDSHAKE_EX_ORDER serverHandshake = { 0 };
|
|
UINT error;
|
|
|
|
if (!rail || !context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!rail_is_feature_supported(rail->rdpcontext, RAIL_LEVEL_HANDSHAKE_EX_SUPPORTED))
|
|
return ERROR_BAD_CONFIGURATION;
|
|
|
|
if ((error = rail_read_handshake_ex_order(s, &serverHandshake)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_handshake_ex_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
rail->channelBuildNumber = serverHandshake.buildNumber;
|
|
rail->channelFlags = serverHandshake.railHandshakeFlags;
|
|
|
|
if (rail->sendHandshake)
|
|
{
|
|
RAIL_HANDSHAKE_ORDER clientHandshake = { 0 };
|
|
clientHandshake.buildNumber = 0x00001DB0;
|
|
/* 2.2.2.2.3 HandshakeEx PDU (TS_RAIL_ORDER_HANDSHAKE_EX)
|
|
* Client response is really a Handshake PDU */
|
|
error = context->ClientHandshake(context, &clientHandshake);
|
|
}
|
|
|
|
if (error != CHANNEL_RC_OK)
|
|
return error;
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerHandshakeEx, error, context, &serverHandshake);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerHandshakeEx failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_exec_result_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_EXEC_RESULT_ORDER execResult = { 0 };
|
|
UINT error;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_server_exec_result_order(s, &execResult)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_server_exec_result_order failed with error %" PRIu32 "!", error);
|
|
goto fail;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerExecuteResult, error, context, &execResult);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerExecuteResult failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
fail:
|
|
free(execResult.exeOrFile.string);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_server_sysparam_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_SYSPARAM_ORDER sysparam;
|
|
UINT error;
|
|
BOOL extendedSpiSupported;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
extendedSpiSupported = rail_is_extended_spi_supported(rail->channelFlags);
|
|
if ((error = rail_read_sysparam_order(s, &sysparam, extendedSpiSupported)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_sysparam_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerSystemParam, error, context, &sysparam);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerSystemParam failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_server_minmaxinfo_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_MINMAXINFO_ORDER minMaxInfo = { 0 };
|
|
UINT error;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_server_minmaxinfo_order(s, &minMaxInfo)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_server_minmaxinfo_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerMinMaxInfo, error, context, &minMaxInfo);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerMinMaxInfo failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_server_localmovesize_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_LOCALMOVESIZE_ORDER localMoveSize = { 0 };
|
|
UINT error;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_server_localmovesize_order(s, &localMoveSize)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_server_localmovesize_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerLocalMoveSize, error, context, &localMoveSize);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerLocalMoveSize failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_server_get_appid_resp_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_GET_APPID_RESP_ORDER getAppIdResp = { 0 };
|
|
UINT error;
|
|
|
|
if (!context || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_server_get_appid_resp_order(s, &getAppIdResp)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_server_get_appid_resp_order failed with error %" PRIu32 "!",
|
|
error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerGetAppIdResponse, error, context, &getAppIdResp);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerGetAppIdResponse failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
static UINT rail_recv_langbar_info_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_LANGBAR_INFO_ORDER langBarInfo = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!rail_is_feature_supported(rail->rdpcontext, RAIL_LEVEL_DOCKED_LANGBAR_SUPPORTED))
|
|
return ERROR_BAD_CONFIGURATION;
|
|
|
|
if ((error = rail_read_langbar_info_order(s, &langBarInfo)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_langbar_info_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerLanguageBarInfo, error, context, &langBarInfo);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerLanguageBarInfo failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_read_taskbar_info_order(wStream* s, RAIL_TASKBAR_INFO_ORDER* taskbarInfo)
|
|
{
|
|
if (!s || !taskbarInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_TASKBAR_INFO_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, taskbarInfo->TaskbarMessage);
|
|
Stream_Read_UINT32(s, taskbarInfo->WindowIdTab);
|
|
Stream_Read_UINT32(s, taskbarInfo->Body);
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_recv_taskbar_info_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_TASKBAR_INFO_ORDER taskBarInfo = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
/* 2.2.2.14.1 Taskbar Tab Info PDU (TS_RAIL_ORDER_TASKBARINFO)
|
|
* server -> client message only supported if announced. */
|
|
if (!rail_is_feature_supported(rail->rdpcontext, RAIL_LEVEL_SHELL_INTEGRATION_SUPPORTED))
|
|
return ERROR_BAD_CONFIGURATION;
|
|
|
|
if ((error = rail_read_taskbar_info_order(s, &taskBarInfo)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_langbar_info_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerTaskBarInfo, error, context, &taskBarInfo);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerTaskBarInfo failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_read_zorder_sync_order(wStream* s, RAIL_ZORDER_SYNC* zorder)
|
|
{
|
|
if (!s || !zorder)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_Z_ORDER_SYNC_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, zorder->windowIdMarker);
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_recv_zorder_sync_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_ZORDER_SYNC zorder = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((rail->clientStatus.flags & TS_RAIL_CLIENTSTATUS_ZORDER_SYNC) == 0)
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if ((error = rail_read_zorder_sync_order(s, &zorder)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_zorder_sync_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerZOrderSync, error, context, &zorder);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerZOrderSync failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_read_cloak_order(wStream* s, RAIL_CLOAK* cloak)
|
|
{
|
|
BYTE cloaked;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_CLOAK_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, cloak->windowId); /* WindowId (4 bytes) */
|
|
Stream_Read_UINT8(s, cloaked); /* Cloaked (1 byte) */
|
|
cloak->cloak = (cloaked != 0) ? TRUE : FALSE;
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_recv_cloak_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_CLOAK cloak = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
/* 2.2.2.12.1 Window Cloak State Change PDU (TS_RAIL_ORDER_CLOAK)
|
|
* server -> client message only supported if announced. */
|
|
if ((rail->clientStatus.flags & TS_RAIL_CLIENTSTATUS_BIDIRECTIONAL_CLOAK_SUPPORTED) == 0)
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if ((error = rail_read_cloak_order(s, &cloak)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_zorder_sync_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerCloak, error, context, &cloak);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerZOrderSync failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_read_power_display_request_order(wStream* s, RAIL_POWER_DISPLAY_REQUEST* power)
|
|
{
|
|
UINT32 active;
|
|
|
|
if (!s || !power)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, RAIL_POWER_DISPLAY_REQUEST_ORDER_LENGTH))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, active);
|
|
power->active = active != 0;
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_recv_power_display_request_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_POWER_DISPLAY_REQUEST power = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
/* 2.2.2.13.1 Power Display Request PDU(TS_RAIL_ORDER_POWER_DISPLAY_REQUEST)
|
|
*/
|
|
if ((rail->clientStatus.flags & TS_RAIL_CLIENTSTATUS_POWER_DISPLAY_REQUEST_SUPPORTED) == 0)
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if ((error = rail_read_power_display_request_order(s, &power)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_zorder_sync_order failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerPowerDisplayRequest, error, context, &power);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerPowerDisplayRequest failed with error %" PRIu32 "", error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
static UINT rail_read_get_application_id_extended_response_order(wStream* s,
|
|
RAIL_GET_APPID_RESP_EX* id)
|
|
{
|
|
if (!s || !id)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, 4))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, id->windowID);
|
|
|
|
if (!Stream_Read_UTF16_String(s, id->applicationID, ARRAYSIZE(id->applicationID)))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if (_wcsnlen(id->applicationID, ARRAYSIZE(id->applicationID)) >= ARRAYSIZE(id->applicationID))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if (!Stream_CheckAndLogRequiredLength(TAG, s, 4))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
Stream_Read_UINT32(s, id->processId);
|
|
|
|
if (!Stream_Read_UTF16_String(s, id->processImageName, ARRAYSIZE(id->processImageName)))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
if (_wcsnlen(id->applicationID, ARRAYSIZE(id->processImageName)) >=
|
|
ARRAYSIZE(id->processImageName))
|
|
return ERROR_INVALID_DATA;
|
|
|
|
return CHANNEL_RC_OK;
|
|
}
|
|
|
|
static UINT rail_recv_get_application_id_extended_response_order(railPlugin* rail, wStream* s)
|
|
{
|
|
RailClientContext* context = rail_get_client_interface(rail);
|
|
RAIL_GET_APPID_RESP_EX id = { 0 };
|
|
UINT error;
|
|
|
|
if (!context)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_get_application_id_extended_response_order(s, &id)))
|
|
{
|
|
WLog_ERR(TAG,
|
|
"rail_read_get_application_id_extended_response_order failed with error %" PRIu32
|
|
"!",
|
|
error);
|
|
return error;
|
|
}
|
|
|
|
if (context->custom)
|
|
{
|
|
IFCALLRET(context->ServerGetAppidResponseExtended, error, context, &id);
|
|
|
|
if (error)
|
|
WLog_ERR(TAG, "context.ServerGetAppidResponseExtended failed with error %" PRIu32 "",
|
|
error);
|
|
}
|
|
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_order_recv(LPVOID userdata, wStream* s)
|
|
{
|
|
railPlugin* rail = userdata;
|
|
UINT16 orderType;
|
|
UINT16 orderLength;
|
|
UINT error = CHANNEL_RC_OK;
|
|
|
|
if (!rail || !s)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if ((error = rail_read_pdu_header(s, &orderType, &orderLength)))
|
|
{
|
|
WLog_ERR(TAG, "rail_read_pdu_header failed with error %" PRIu32 "!", error);
|
|
return error;
|
|
}
|
|
|
|
WLog_Print(rail->log, WLOG_DEBUG, "Received %s PDU, length:%" PRIu16 "",
|
|
rail_get_order_type_string(orderType), orderLength);
|
|
|
|
switch (orderType)
|
|
{
|
|
case TS_RAIL_ORDER_HANDSHAKE:
|
|
error = rail_recv_handshake_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_HANDSHAKE_EX:
|
|
error = rail_recv_handshake_ex_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_EXEC_RESULT:
|
|
error = rail_recv_exec_result_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_SYSPARAM:
|
|
error = rail_recv_server_sysparam_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_MINMAXINFO:
|
|
error = rail_recv_server_minmaxinfo_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_LOCALMOVESIZE:
|
|
error = rail_recv_server_localmovesize_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_GET_APPID_RESP:
|
|
error = rail_recv_server_get_appid_resp_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_LANGBARINFO:
|
|
error = rail_recv_langbar_info_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_TASKBARINFO:
|
|
error = rail_recv_taskbar_info_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_ZORDER_SYNC:
|
|
error = rail_recv_zorder_sync_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_CLOAK:
|
|
error = rail_recv_cloak_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_POWER_DISPLAY_REQUEST:
|
|
error = rail_recv_power_display_request_order(rail, s);
|
|
break;
|
|
|
|
case TS_RAIL_ORDER_GET_APPID_RESP_EX:
|
|
error = rail_recv_get_application_id_extended_response_order(rail, s);
|
|
break;
|
|
|
|
default:
|
|
WLog_ERR(TAG, "Unknown RAIL PDU order 0x%08" PRIx32 " received.", orderType);
|
|
return ERROR_INVALID_DATA;
|
|
}
|
|
|
|
if (error != CHANNEL_RC_OK)
|
|
{
|
|
WLog_Print(rail->log, WLOG_ERROR, "Failed to process rail %s PDU, length:%" PRIu16 "",
|
|
rail_get_order_type_string(orderType), orderLength);
|
|
}
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_handshake_order(railPlugin* rail, const RAIL_HANDSHAKE_ORDER* handshake)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !handshake)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_HANDSHAKE_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
rail_write_handshake_order(s, handshake);
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_HANDSHAKE);
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_handshake_ex_order(railPlugin* rail, const RAIL_HANDSHAKE_EX_ORDER* handshakeEx)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !handshakeEx)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_HANDSHAKE_EX_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
rail_write_handshake_ex_order(s, handshakeEx);
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_HANDSHAKE_EX);
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_status_order(railPlugin* rail, const RAIL_CLIENT_STATUS_ORDER* clientStatus)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !clientStatus)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
rail->clientStatus = *clientStatus;
|
|
s = rail_pdu_init(RAIL_CLIENT_STATUS_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_status_order(s, clientStatus);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_CLIENTSTATUS);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_exec_order(railPlugin* rail, UINT16 flags,
|
|
const RAIL_UNICODE_STRING* exeOrFile,
|
|
const RAIL_UNICODE_STRING* workingDir,
|
|
const RAIL_UNICODE_STRING* arguments)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
size_t length;
|
|
|
|
if (!rail || !exeOrFile || !workingDir || !arguments)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
length = RAIL_EXEC_ORDER_LENGTH + exeOrFile->length + workingDir->length + arguments->length;
|
|
s = rail_pdu_init(length);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
if ((error = rail_write_client_exec_order(s, flags, exeOrFile, workingDir, arguments)))
|
|
{
|
|
WLog_ERR(TAG, "rail_write_client_exec_order failed with error %" PRIu32 "!", error);
|
|
goto out;
|
|
}
|
|
|
|
if ((error = rail_send_pdu(rail, s, TS_RAIL_ORDER_EXEC)))
|
|
{
|
|
WLog_ERR(TAG, "rail_send_pdu failed with error %" PRIu32 "!", error);
|
|
goto out;
|
|
}
|
|
|
|
out:
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_activate_order(railPlugin* rail, const RAIL_ACTIVATE_ORDER* activate)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !activate)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_ACTIVATE_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_activate_order(s, activate);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_ACTIVATE);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_sysmenu_order(railPlugin* rail, const RAIL_SYSMENU_ORDER* sysmenu)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !sysmenu)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_SYSMENU_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_sysmenu_order(s, sysmenu);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_SYSMENU);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_syscommand_order(railPlugin* rail, const RAIL_SYSCOMMAND_ORDER* syscommand)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !syscommand)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_SYSCOMMAND_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_syscommand_order(s, syscommand);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_SYSCOMMAND);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_notify_event_order(railPlugin* rail,
|
|
const RAIL_NOTIFY_EVENT_ORDER* notifyEvent)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !notifyEvent)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_NOTIFY_EVENT_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_notify_event_order(s, notifyEvent);
|
|
|
|
if (ERROR_SUCCESS == error)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_NOTIFY_EVENT);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_window_move_order(railPlugin* rail, const RAIL_WINDOW_MOVE_ORDER* windowMove)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !windowMove)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_WINDOW_MOVE_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_window_move_order(s, windowMove);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_WINDOWMOVE);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_get_appid_req_order(railPlugin* rail,
|
|
const RAIL_GET_APPID_REQ_ORDER* getAppIdReq)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !getAppIdReq)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_GET_APPID_REQ_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_client_get_appid_req_order(s, getAppIdReq);
|
|
|
|
if (error == ERROR_SUCCESS)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_GET_APPID_REQ);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
/**
|
|
* Function description
|
|
*
|
|
* @return 0 on success, otherwise a Win32 error code
|
|
*/
|
|
UINT rail_send_client_langbar_info_order(railPlugin* rail,
|
|
const RAIL_LANGBAR_INFO_ORDER* langBarInfo)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !langBarInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!rail_is_feature_supported(rail->rdpcontext, RAIL_LEVEL_DOCKED_LANGBAR_SUPPORTED))
|
|
return ERROR_BAD_CONFIGURATION;
|
|
|
|
s = rail_pdu_init(RAIL_LANGBAR_INFO_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_langbar_info_order(s, langBarInfo);
|
|
|
|
if (ERROR_SUCCESS == error)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_LANGBARINFO);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
UINT rail_send_client_languageime_info_order(railPlugin* rail,
|
|
const RAIL_LANGUAGEIME_INFO_ORDER* langImeInfo)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !langImeInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
if (!rail_is_feature_supported(rail->rdpcontext, RAIL_LEVEL_LANGUAGE_IME_SYNC_SUPPORTED))
|
|
return ERROR_BAD_CONFIGURATION;
|
|
|
|
s = rail_pdu_init(RAIL_LANGUAGEIME_INFO_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_languageime_info_order(s, langImeInfo);
|
|
|
|
if (ERROR_SUCCESS == error)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_LANGUAGEIMEINFO);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
UINT rail_send_client_compartment_info_order(railPlugin* rail,
|
|
const RAIL_COMPARTMENT_INFO_ORDER* compartmentInfo)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !compartmentInfo)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(RAIL_COMPARTMENT_INFO_ORDER_LENGTH);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
error = rail_write_compartment_info_order(s, compartmentInfo);
|
|
|
|
if (ERROR_SUCCESS == error)
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_COMPARTMENTINFO);
|
|
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
UINT rail_send_client_cloak_order(railPlugin* rail, const RAIL_CLOAK* cloak)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail || !cloak)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
s = rail_pdu_init(5);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
Stream_Write_UINT32(s, cloak->windowId);
|
|
Stream_Write_UINT8(s, cloak->cloak ? 1 : 0);
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_CLOAK);
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|
|
|
|
UINT rail_send_client_snap_arrange_order(railPlugin* rail, const RAIL_SNAP_ARRANGE* snap)
|
|
{
|
|
wStream* s;
|
|
UINT error;
|
|
|
|
if (!rail)
|
|
return ERROR_INVALID_PARAMETER;
|
|
|
|
/* 2.2.2.7.5 Client Window Snap PDU (TS_RAIL_ORDER_SNAP_ARRANGE) */
|
|
if ((rail->channelFlags & TS_RAIL_ORDER_HANDSHAKE_EX_FLAGS_SNAP_ARRANGE_SUPPORTED) == 0)
|
|
{
|
|
RAIL_WINDOW_MOVE_ORDER move = { 0 };
|
|
move.top = snap->top;
|
|
move.left = snap->left;
|
|
move.right = snap->right;
|
|
move.bottom = snap->bottom;
|
|
move.windowId = snap->windowId;
|
|
return rail_send_client_window_move_order(rail, &move);
|
|
}
|
|
|
|
s = rail_pdu_init(12);
|
|
|
|
if (!s)
|
|
{
|
|
WLog_ERR(TAG, "rail_pdu_init failed!");
|
|
return CHANNEL_RC_NO_MEMORY;
|
|
}
|
|
|
|
Stream_Write_UINT32(s, snap->windowId);
|
|
Stream_Write_INT16(s, snap->left);
|
|
Stream_Write_INT16(s, snap->top);
|
|
Stream_Write_INT16(s, snap->right);
|
|
Stream_Write_INT16(s, snap->bottom);
|
|
error = rail_send_pdu(rail, s, TS_RAIL_ORDER_SNAP_ARRANGE);
|
|
Stream_Free(s, TRUE);
|
|
return error;
|
|
}
|