- Undocumented "legacy" register at offset 0x1b is used to probe for the ES1370 interrupt by the Win9x driver. Using bit #0 to control the IRQ line fixes driver installation. - Added more detailed BX_ERROR messages for the UART registers. - Small code cleanup in the write handler. - TODO: fix possible bluescreen in Win98 guest after wave playback. |
||
---|---|---|