From his patch file text:
> This patch adds Promise DC2300 VLB IDE Support.
> You may find msdos and win95 drivers on the net. Look for
> P2300W95.ZIP and DC2300VLBIDEver260b.ZIP.
>
> The good news is that now win95 natively sees my cdrom,
> and that the disks are not in msdos compatibility mode any more.
>
> The bad news is that it works only for the first ata interface.
>
> I tested that patch on msdos and win95 only.
>
> Some info on VLB IDE can be found at http://ryston.cz/petr/vlb/
I got Win95 running with 32-bit paging/filesystem using the
recommended driver and these patches. Since the patches did
such a good job bracketing code modifications with a #define,
they might as well become part of the current CVS code.
- Features :
. number of active channels defined at boot-time config
. new options in bochsrc
. up to 8 devices support (disks or cdroms)
. up to 4 cdrom devices can be changed at runtime config
. wxwindows config interface
Some devices already had one. Some I had to add an empty one.
I did a little cleaning of init() methods to make them more uniform
but generally I left them alone.
- I also put these exact diffs into a patch "patch.iodev-add-reset"
in case I want to revert these changes for some reason, for example
if they break an old patch. It should be deleted after a while.
of just panicing. In particular, if the logical sector is out of bounds
or the disk image cannot be read/written at the desired offset, we now
abort the ATA command and return an error code. Many of the old BX_PANIC
messages are turned to BX_ERROR, so they will still appear in the
log, but now the device model will try to communicate this fact to
the OS instead of simply giving up.
To see the commit logs for this use either cvsweb or
cvs update -r BRANCH-io-cleanup and then 'cvs log' the various files.
In general this provides a generic interface for logging.
logfunctions:: is a class that is inherited by some classes, and also
. allocated as a standalone global called 'genlog'. All logging uses
. one of the ::info(), ::error(), ::ldebug(), ::panic() methods of this
. class through 'BX_INFO(), BX_ERROR(), BX_DEBUG(), BX_PANIC()' macros
. respectively.
.
. An example usage:
. BX_INFO(("Hello, World!\n"));
iofunctions:: is a class that is allocated once by default, and assigned
as the iofunction of each logfunctions instance. It is this class that
maintains the file descriptor and other output related code, at this
point using vfprintf(). At some future point, someone may choose to
write a gui 'console' for bochs to which messages would be redirected
simply by assigning a different iofunction class to the various logfunctions
objects.
More cleanup is coming, but this works for now. If you want to see alot
of debugging output, in main.cc, change onoff[LOGLEV_DEBUG]=0 to =1.
Comments, bugs, flames, to me: todd@fries.net