* Bug fix: The configuration dialog was never opened, because it could
read the attribute "transport_address" created and set to an empty string by the print_server when the printer was created. fEndpoint used an empty host name to connect to and then failed. Not sure why this caused a crash after closing the error dialog. Maybe something went wrong in the destructor using an invalid fEndpoint? Cures the symptoms of ticket #6973. git-svn-id: file:///srv/svn/repos/haiku/haiku/trunk@39818 a95241bf-73f2-0310-859d-f6bbb57e9c96
This commit is contained in:
parent
2e3906da98
commit
b12b2a60a7
|
@ -29,7 +29,8 @@ HPJetDirectPort::HPJetDirectPort(BDirectory* printer, BMessage *msg)
|
|||
{
|
||||
BString address;
|
||||
|
||||
if (printer->ReadAttrString("transport_address", &address) < 0) {
|
||||
if (printer->ReadAttrString("transport_address", &address) < 0
|
||||
|| address.Length() == 0) {
|
||||
SetupWindow *setup = new SetupWindow(printer);
|
||||
if (setup->Go() == B_ERROR)
|
||||
return;
|
||||
|
|
Loading…