211 lines
5.5 KiB
Groff
211 lines
5.5 KiB
Groff
.\" $NetBSD: chio.1,v 1.2 1997/09/15 13:23:01 lukem Exp $
|
|
.\"
|
|
.\" Copyright (c) 1996 Jason R. Thorpe <thorpej@and.com>
|
|
.\" All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\" 3. All advertising materials mentioning features or use of this software
|
|
.\" must display the following acknowledgements:
|
|
.\" This product includes software developed by Jason R. Thorpe
|
|
.\" for And Communications, http://www.and.com/
|
|
.\" 4. The name of the author may not be used to endorse or promote products
|
|
.\" derived from this software without specific prior written permission.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
|
|
.\" BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
|
|
.\" LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
|
|
.\" AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
|
|
.\" OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
.\" SUCH DAMAGE.
|
|
.\"
|
|
.Dd April 2, 1996
|
|
.Dt CHIO 1
|
|
.Os NetBSD
|
|
.Sh NAME
|
|
.Nm chio
|
|
.Nd medium changer control utility
|
|
.Sh SYNOPSIS
|
|
.Nm
|
|
.Op Fl f Ar changer
|
|
.Ar command
|
|
.Ar arg1
|
|
.Ar arg2
|
|
.Oo
|
|
.Ar arg3 Oo ...
|
|
.Oc
|
|
.Oc
|
|
.Sh DESCRIPTION
|
|
.Nm
|
|
is used to control the operation of medium changers, such as those found
|
|
in tape and optical disk jukeboxes.
|
|
.Pp
|
|
The options are as follows:
|
|
.Bl -tag -width indent
|
|
.It Fl f Ar changer
|
|
Use the device
|
|
.Pa changer
|
|
rather than the default device
|
|
.Pa /dev/ch0 .
|
|
.El
|
|
.Pp
|
|
The default changer may be overridden by setting the environment variable
|
|
.Ev CHANGER
|
|
to the desired changer device.
|
|
.Pp
|
|
A medium changer apparatus is made up of
|
|
.Pa elements .
|
|
There are four element types:
|
|
.Pa picker
|
|
(medium transport),
|
|
.Pa slot
|
|
(storage),
|
|
.Pa portal
|
|
(import/export), and
|
|
.Pa drive
|
|
(data transfer). In this command description, the shorthand
|
|
.Ic ET
|
|
will be used to represent an element type, and
|
|
.Ic EU
|
|
will be used to represent an element unit. For example, to represent
|
|
the first robotic arm in the changer, the ET would be
|
|
.Dq picker
|
|
and the EU would be
|
|
.Dq 0 .
|
|
.Pp
|
|
.Sh SUPPORTED COMMANDS
|
|
.Nm
|
|
.Ic move
|
|
.Ar <from ET> <from EU> <to ET> <to EU>
|
|
.Op Ar inv
|
|
.Pp
|
|
Moves the media unit from
|
|
.Pa <from ET/EU>
|
|
to
|
|
.Pa <to ET/EU> .
|
|
If the optional modifier
|
|
.Pa inv
|
|
is specified, the media unit will be inverted before insertion.
|
|
.Pp
|
|
.Nm
|
|
.Ic exchange
|
|
.Ar <src ET> <src EU> <dst1 ET> <dst1 EU>
|
|
.Op Ar <dst2 ET> <dst2 ET>
|
|
.Op Ar inv1
|
|
.Op Ar inv2
|
|
.Pp
|
|
Performs a media unit exchange operation. The media unit in
|
|
.Pa <src ET/EU>
|
|
is moved to
|
|
.Pa <dst1 ET/EU>
|
|
and the media unit previously in
|
|
.Pa <dst1 ET/EU>
|
|
is moved to
|
|
.Pa <dst2 ET/EU> .
|
|
In the case of a simple exchange,
|
|
.Pa <dst2 ET/EU>
|
|
is omitted and the values
|
|
.Pa <src ET/EU>
|
|
are used in their place.
|
|
The optional modifiers
|
|
.Pa inv1
|
|
and
|
|
.Pa inv2
|
|
specify whether the media units are to be inverted before insertion into
|
|
.Pa <dst1 ET/EU>
|
|
and
|
|
.Pa <dst2 ET/EU>
|
|
respecitively.
|
|
.Pp
|
|
Note that not all medium changers support the
|
|
.Ic exchange
|
|
operation; The changer must have multiple free pickers or emulate
|
|
multiple free pickers with transient storage.
|
|
.Pp
|
|
.Nm
|
|
.Ic position
|
|
.Ar <to ET> <to EU>
|
|
.Op Ar inv
|
|
.Pp
|
|
Position the picker in front of the element described by
|
|
.Pa <to ET/EU> .
|
|
If the optional modifier
|
|
.Pa inv
|
|
is specified, the media unit will be inverted before insertion.
|
|
.Pp
|
|
Note that not all changers behave as expected when issued this command.
|
|
.Pp
|
|
.Nm
|
|
.Ic params
|
|
.Pp
|
|
Report the number of slots, drives, pickers, and portals in the changer,
|
|
and which picker unit the changer is currently configured to use.
|
|
.Pp
|
|
.Nm
|
|
.Ic getpicker
|
|
.Pp
|
|
Report which picker unit the changer is currently configured to use.
|
|
.Pp
|
|
.Nm
|
|
.Ic setpicker
|
|
.Ar <unit>
|
|
.Pp
|
|
Configure the changer to use picker
|
|
.Pa <unit> .
|
|
.Pp
|
|
.Nm
|
|
.Ic status
|
|
.Op Ar <type>
|
|
.Pp
|
|
Report the status of all elements in the changer. If
|
|
.Pa <type>
|
|
is specified, report the status of all elements of type
|
|
.Pa <type> .
|
|
.Pp
|
|
The status bits are defined as follows:
|
|
.Bl -tag -width indent
|
|
.It Nm FULL
|
|
Element contains a media unit.
|
|
.It Nm IMPEXP
|
|
Media was deposited into element by an outside human operator.
|
|
.It Nm EXCEPT
|
|
Element is in an abnormal state.
|
|
.It Nm ACCESS
|
|
Media in this element is accessible by a picker.
|
|
.It Nm EXENAB
|
|
Element supports passing media (exporting) to an outsite human operator.
|
|
.It Nm INENAB
|
|
Element supports receiving media (importing) from an outside human operator.
|
|
.El
|
|
.Pp
|
|
.Sh EXAMPLES
|
|
.Dl chio move slot 3 drive 0
|
|
.Pp
|
|
Moves the media in slot 3 (fourth slot) to drive 0 (first drive).
|
|
.Pp
|
|
.Dl chio setpicker 2
|
|
.Pp
|
|
Configures the changer to use picker 2 (third picker) for operations.
|
|
.Pp
|
|
.Sh FILES
|
|
/dev/ch0 - default changer device
|
|
.Sh SEE ALSO
|
|
.Xr mt 1 ,
|
|
.Xr mount 8 .
|
|
.Sh AUTHOR
|
|
The
|
|
.Nm
|
|
program and SCSI changer driver were written by Jason R. Thorpe
|
|
<thorpej@and.com> for And Communications, http://www.and.com/
|