NetBSD/lib/libc/rpc/rpc_com.h

85 lines
2.8 KiB
C

/* $NetBSD: rpc_com.h,v 1.3 2000/12/10 04:10:08 christos Exp $ */
/*
* Sun RPC is a product of Sun Microsystems, Inc. and is provided for
* unrestricted use provided that this legend is included on all tape
* media and as a part of the software program in whole or part. Users
* may copy or modify Sun RPC without charge, but are not authorized
* to license or distribute it to anyone else except as part of a product or
* program developed by the user.
*
* SUN RPC IS PROVIDED AS IS WITH NO WARRANTIES OF ANY KIND INCLUDING THE
* WARRANTIES OF DESIGN, MERCHANTIBILITY AND FITNESS FOR A PARTICULAR
* PURPOSE, OR ARISING FROM A COURSE OF DEALING, USAGE OR TRADE PRACTICE.
*
* Sun RPC is provided with no support and without any obligation on the
* part of Sun Microsystems, Inc. to assist in its use, correction,
* modification or enhancement.
*
* SUN MICROSYSTEMS, INC. SHALL HAVE NO LIABILITY WITH RESPECT TO THE
* INFRINGEMENT OF COPYRIGHTS, TRADE SECRETS OR ANY PATENTS BY SUN RPC
* OR ANY PART THEREOF.
*
* In no event will Sun Microsystems, Inc. be liable for any lost revenue
* or profits or other special, indirect and consequential damages, even if
* Sun has been advised of the possibility of such damages.
*
* Sun Microsystems, Inc.
* 2550 Garcia Avenue
* Mountain View, California 94043
*/
/*
* Copyright (c) 1986 - 1991 by Sun Microsystems, Inc.
*/
/*
* rpc_com.h, Common definitions for both the server and client side.
* All for the topmost layer of rpc
*
* In Sun's tirpc distribution, this was installed as <rpc/rpc_com.h>,
* but as it contains only non-exported interfaces, it was moved here.
*/
#ifndef _RPC_RPCCOM_H
#define _RPC_RPCCOM_H
#include <sys/cdefs.h>
/* #pragma ident "@(#)rpc_com.h 1.11 93/07/05 SMI" */
/*
* The max size of the transport, if the size cannot be determined
* by other means.
*/
#define RPC_MAXDATASIZE 9000
#define RPC_MAXADDRSIZE 1024
#define __RPC_GETXID(now) ((u_int32_t)getpid() ^ (u_int32_t)(now)->tv_sec ^ \
(u_int32_t)(now)->tv_usec)
__BEGIN_DECLS
extern u_int __rpc_get_a_size __P((int));
extern int __rpc_dtbsize __P((void));
extern struct netconfig * __rpcgettp __P((int));
extern int __rpc_get_default_domain __P((char **));
char *__rpc_taddr2uaddr_af __P((int, const struct netbuf *));
struct netbuf *__rpc_uaddr2taddr_af __P((int, const char *));
int __rpc_fixup_addr __P((struct netbuf *, const struct netbuf *));
int __rpc_sockinfo2netid __P((struct __rpc_sockinfo *, const char **));
int __rpc_seman2socktype __P((int));
int __rpc_socktype2seman __P((int));
void *rpc_nullproc __P((CLIENT *));
int __rpc_sockisbound __P((int));
struct netbuf *__rpcb_findaddr __P((rpcprog_t, rpcvers_t,
const struct netconfig *,
const char *, CLIENT **));
bool_t __rpc_control __P((int,void *));
char *_get_next_token __P((char *, int));
__END_DECLS
#endif /* _RPC_RPCCOM_H */