371 lines
12 KiB
Plaintext
371 lines
12 KiB
Plaintext
/* $NetBSD: menus.mi.fr,v 1.6 1998/02/09 07:03:42 phil Exp $ */
|
||
|
||
/*
|
||
* Copyright 1997 Piermont Information Systems Inc.
|
||
* All rights reserved.
|
||
*
|
||
* Written by Philip A. Nelson for Piermont Information Systems Inc.
|
||
*
|
||
* Redistribution and use in source and binary forms, with or without
|
||
* modification, are permitted provided that the following conditions
|
||
* are met:
|
||
* 1. Redistributions of source code must retain the above copyright
|
||
* notice, this list of conditions and the following disclaimer.
|
||
* 2. Redistributions in binary form must reproduce the above copyright
|
||
* notice, this list of conditions and the following disclaimer in the
|
||
* documentation and/or other materials provided with the distribution.
|
||
* 3. All advertising materials mentioning features or use of this software
|
||
* must display the following acknowledgement:
|
||
* This product includes software develooped for the NetBSD Project by
|
||
* Piermont Information Systems Inc.
|
||
* 4. The name of Piermont Information Systems Inc. may not be used to endorse
|
||
* or promote products derived from this software without specific prior
|
||
* written permission.
|
||
*
|
||
* THIS SOFTWARE IS PROVIDED BY PIERMONT INFORMATION SYSTEMS INC. ``AS IS''
|
||
* AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
||
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
||
* ARE DISCLAIMED. IN NO EVENT SHALL PIERMONT INFORMATION SYSTEMS INC. BE
|
||
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
||
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
||
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
||
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
||
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
||
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF
|
||
* THE POSSIBILITY OF SUCH DAMAGE.
|
||
*
|
||
*/
|
||
|
||
/*
|
||
* Menu system definitions -- machine independent
|
||
*
|
||
* Some menus may be called directly in the code rather than via the
|
||
* menu system.
|
||
*
|
||
* This file must be first in the sed command line.
|
||
*
|
||
*/
|
||
|
||
{
|
||
#include <stdio.h>
|
||
#include <curses.h>
|
||
#include "defs.h"
|
||
#include "md.h"
|
||
#include "msg_defs.h"
|
||
#include "menu_defs.h"
|
||
}
|
||
|
||
default x=20, y=12, no exit;
|
||
|
||
menu netbsd, title " NetBSD-@@VERSION@@ Programme d'installation";
|
||
display action { toplevel(); };
|
||
option "Installation de NetBSD sur disque dur",
|
||
action { do_install(); };
|
||
option "Mise <20> jour de NetBSD sur disque dur",
|
||
action { do_upgrade(); };
|
||
option "R<>installer ou installer de nouveaux composants",
|
||
action { do_reinstall_sets(); };
|
||
option "Red<65>marrer l'ordinateur", exit,
|
||
action (endwin) { run_prog("/sbin/reboot"); };
|
||
option "Menu utilitaire", sub menu utility;
|
||
option "Quitter le programme d'installation", exit;
|
||
|
||
menu utility, title " Utilitaires NetBSD-@@VERSION@@", exit;
|
||
option "Ex<45>cuter /bin/sh",
|
||
action (endwin) { system("/bin/sh"); };
|
||
option "Configuration du r<>seau",
|
||
action {
|
||
extern int network_up;
|
||
|
||
network_up = 0;
|
||
config_network();
|
||
};
|
||
/* option "Partitioner un disque"; XXX add later. */
|
||
option "Arr<72>ter le syst<73>me", exit,
|
||
action (endwin) { run_prog("/sbin/halt"); };
|
||
|
||
menu yesno, title " oui ou non? ";
|
||
option "Oui", exit, action {yesno = 1;};
|
||
option "Non", exit, action {yesno = 0;};
|
||
|
||
menu noyes, title " oui ou non? ";
|
||
option "Non", exit, action {yesno = 0;};
|
||
option "Oui", exit, action {yesno = 1;};
|
||
|
||
menu ok, title " Presser entr<74>e pour continuer ";
|
||
option "ok", exit;
|
||
|
||
menu scsigeom1, title " Choisissez une option";
|
||
display action {
|
||
msg_display (MSG_scsigeom1, diskdev, disk->geom[4],
|
||
dlcyl, dlhead, dlsec, dlcyl*dlhead*dlsec,
|
||
disk->geom[0], disk->geom[1], disk->geom[2],
|
||
disk->geom[0]*disk->geom[1]*disk->geom[2]);
|
||
};
|
||
option "Utiliser la g<>om<6F>trie r<>elle", exit, action {
|
||
dlcyl = disk->geom[0];
|
||
dlhead = disk->geom[1];
|
||
dlsec = disk->geom[2];
|
||
};
|
||
option "Utiliser la g<>om<6F>trie du disklabel", exit, action {
|
||
disk->geom[0] = dlcyl;
|
||
disk->geom[1] = dlhead;
|
||
disk->geom[2] = dlsec;
|
||
};
|
||
option "Choisir une g<>om<6F>trie maison", action { scsi_fake ();}, exit;
|
||
|
||
menu scsigeom2, title " Choisissez une option";
|
||
display action {
|
||
msg_display (MSG_scsigeom2, diskdev, disk->geom[4],
|
||
disk->geom[0], disk->geom[1], disk->geom[2],
|
||
disk->geom[0]*disk->geom[1]*disk->geom[2]);
|
||
};
|
||
option " Utiliser la g<>om<6F>trie r<>elle ", exit, action {
|
||
dlcyl = disk->geom[0];
|
||
dlhead = disk->geom[1];
|
||
dlsec = disk->geom[2];
|
||
};
|
||
option " Choisir une g<>om<6F>trie maison", action { scsi_fake ();}, exit;
|
||
|
||
menu scsi_fake, title " Choisissez une g<>om<6F>trie";
|
||
option "G<>om<6F>trie 1", action { fake_sel = 0; }, exit;
|
||
option "G<>om<6F>trie 2", action { fake_sel = 1; }, exit;
|
||
option "G<>om<6F>trie 3", action { fake_sel = 2; }, exit;
|
||
option "G<>om<6F>trie 4", action { fake_sel = 3; }, exit;
|
||
option "G<>om<6F>trie 5", action { fake_sel = 4; }, exit;
|
||
|
||
menu layout, title " Choisissez votre type d'installation ";
|
||
option "Standard", exit, action { layoutkind = 1; };
|
||
option "Standard avec X", exit, action { layoutkind = 2; };
|
||
option "Personnalis<69>e", exit, action { layoutkind = 3; };
|
||
|
||
menu sizechoice, title " Choisissez votre unit<69> d'espace disque";
|
||
option "Megaoctets", exit, action
|
||
{ sizemult = MEG / sectorsize;
|
||
multname = msg_string(MSG_megname);
|
||
};
|
||
option "Cylindres", exit, action
|
||
{ sizemult = dlcylsize;
|
||
multname = msg_string(MSG_cylname);
|
||
};
|
||
option "Secteurs", exit, action
|
||
{ sizemult = 1;
|
||
multname = msg_string(MSG_secname);
|
||
};
|
||
|
||
menu fspartok, title " Partitions ok?", y=15;
|
||
display action {
|
||
msg_display(MSG_fspart, multname);
|
||
disp_cur_fspart(-1, 0);
|
||
};
|
||
option "Les Partitions sont ok", exit;
|
||
option "Changer une partition", sub menu editfsparts;
|
||
|
||
menu edfspart, title " Changer quoi? ", exit, y=15;
|
||
display action {
|
||
msg_display (MSG_edfspart, 'a'+editpart);
|
||
disp_cur_fspart(editpart, 1);
|
||
};
|
||
option "type de FS", sub menu selfskind;
|
||
option "Offset/taille", action
|
||
{ char buf[40]; int start, size;
|
||
msg_prompt_add (MSG_offset, NULL, buf, 40);
|
||
start = NUMSEC(atoi(buf),sizemult,dlcylsize);
|
||
msg_prompt_add (MSG_size, NULL, buf, 40);
|
||
size = NUMSEC(atoi(buf),sizemult,dlcylsize);
|
||
if (size == -1)
|
||
size = dlsize - start;
|
||
if (editpart == 1 &&
|
||
bsdlabel[editpart][D_FSTYPE] == T_SWAP)
|
||
size -= swapadj;
|
||
if (start + size > dlsize)
|
||
size = dlsize - start;
|
||
bsdlabel[editpart][D_OFFSET] = start;
|
||
bsdlabel[editpart][D_SIZE] = size;
|
||
};
|
||
option "Taille de block/Taille de fragment", action
|
||
{ char buf[40]; int i;
|
||
|
||
if (bsdlabel[editpart][D_FSTYPE] != T_42BSD) {
|
||
msg_display (MSG_not42bsd, 'a'+editpart);
|
||
process_menu (MENU_ok);
|
||
return FALSE;
|
||
}
|
||
msg_prompt_add (MSG_bsize, NULL, buf, 40);
|
||
i = atoi(buf);
|
||
bsdlabel[editpart][D_BSIZE] = i;
|
||
msg_prompt_add (MSG_fsize, NULL, buf, 40);
|
||
i = atoi(buf);
|
||
bsdlabel[editpart][D_FSIZE] = i;
|
||
};
|
||
option "Point de montage", action
|
||
{ if (bsdlabel[editpart][D_FSTYPE] == T_42BSD ||
|
||
bsdlabel[editpart][D_FSTYPE] == T_MSDOS)
|
||
msg_prompt_add (MSG_mountpoint, NULL,
|
||
fsmount[editpart], 20);
|
||
else {
|
||
msg_display (MSG_nomount, 'a'+editpart);
|
||
process_menu (MENU_ok);
|
||
}
|
||
};
|
||
|
||
menu selfskind, title " Selection du type de syst<73>me de fichier", y=15;
|
||
option "4.2BSD", exit, action
|
||
{ bsdlabel[editpart][D_FSTYPE] = T_42BSD;
|
||
bsdlabel[editpart][D_BSIZE] = 8192;
|
||
bsdlabel[editpart][D_FSIZE] = 1024;
|
||
};
|
||
option "unused", exit, action
|
||
{ bsdlabel[editpart][D_FSTYPE] = T_UNUSED;
|
||
bsdlabel[editpart][D_BSIZE] = 0;
|
||
bsdlabel[editpart][D_FSIZE] = 0;
|
||
};
|
||
option "swap", exit, action
|
||
{ bsdlabel[editpart][D_FSTYPE] = T_SWAP;
|
||
bsdlabel[editpart][D_BSIZE] = 0;
|
||
bsdlabel[editpart][D_FSIZE] = 0;
|
||
};
|
||
option "msdos", exit, action
|
||
{ bsdlabel[editpart][D_FSTYPE] = T_MSDOS;
|
||
bsdlabel[editpart][D_BSIZE] = 0;
|
||
bsdlabel[editpart][D_FSIZE] = 0;
|
||
};
|
||
|
||
|
||
menu distmedium, title " S<>lection du media d'installation";
|
||
display action { msg_display (MSG_distmedium); nodist = 0; };
|
||
option "ftp", action {
|
||
got_dist = get_via_ftp();
|
||
},
|
||
exit;
|
||
option "nfs", action {
|
||
got_dist = get_via_nfs();
|
||
}, exit;
|
||
option "cdrom", action {
|
||
got_dist = get_via_cdrom();
|
||
}, exit;
|
||
option "disquette", action {
|
||
got_dist = get_via_floppy();
|
||
}, exit;
|
||
|
||
option "systeme de fichier non-mont<6E>", action {
|
||
got_dist = get_via_localfs();
|
||
}, exit;
|
||
option "r<>pertoire local", action {
|
||
got_dist = get_via_localdir();
|
||
}, exit;
|
||
option "aucun", action { nodist = 1; }, exit;
|
||
|
||
menu distset, title " S<>lection de la distribution";
|
||
display action { msg_display (MSG_distset); };
|
||
option "Installation compl<70>te", exit;
|
||
option "Installation personnalis<69>e", next menu md_distcustom;
|
||
|
||
menu ftpsource, title " Changer";
|
||
display action
|
||
{ int i;
|
||
msg_display (MSG_ftpsource, ftp_host, ftp_dir, ftp_user);
|
||
if (strcmp(ftp_user, "ftp") == 0)
|
||
msg_printf_add ("%s", ftp_pass);
|
||
else
|
||
for (i = strlen(ftp_pass); i>0; i--)
|
||
msg_printf_add ("*");
|
||
};
|
||
option "Serveur ftp", action
|
||
{ msg_prompt (MSG_host, NULL, ftp_host, 255); };
|
||
option "R<>pertoire", action
|
||
{ msg_prompt (MSG_dir, NULL, ftp_dir, 255); };
|
||
option "Utilisateur", action
|
||
{ msg_prompt (MSG_user, NULL, ftp_user, 255); };
|
||
option "Mot de passe", action
|
||
{ if (strcmp(ftp_user, "ftp") == 0)
|
||
msg_prompt (MSG_email, NULL, ftp_pass, 255);
|
||
else {
|
||
msg_noecho ();
|
||
msg_prompt (MSG_passwd, NULL, ftp_pass, 255);
|
||
msg_echo ();
|
||
}
|
||
};
|
||
option "R<>cup<75>rer la Distribution", exit;
|
||
|
||
menu nfssource, title " Changer";
|
||
display action
|
||
{ msg_display (MSG_nfssource, nfs_host, nfs_dir); };
|
||
option "Serveur nfs", action
|
||
{ msg_prompt (MSG_host, NULL, nfs_host, 255); };
|
||
option "R<>pertoire", action
|
||
{ msg_prompt (MSG_dir, NULL, nfs_dir, 255); };
|
||
option "Continuer", exit;
|
||
|
||
menu nfsbadmount, title " Que voulez vous faire?";
|
||
option "R<>essayer", exit, sub menu nfssource, action
|
||
{ yesno = 1; ignorerror = 0; };
|
||
option "Abandonner", exit, action
|
||
{ yesno = 1; ignorerror = 0; };
|
||
option "Ignorer les erreurs, continuer quand m<>me", exit, action
|
||
{ yesno = 1; ignorerror = 1; };
|
||
|
||
|
||
menu fdremount, title " Que voulez vous faire? ";
|
||
option "R<>essayer", exit, action { yesno = 1; };
|
||
option "Annuler l'installation", exit, action { yesno = 0; };
|
||
|
||
menu fdok, title " Presser entr<74>e pour continuer ";
|
||
option "OK", exit, action { yesno = 1; };
|
||
option "Abandonner l'installation", exit, action { yesno = 0; };
|
||
|
||
|
||
menu cdromsource, title " Changer";
|
||
display action
|
||
{ msg_display (MSG_cdromsource, cdrom_dev, cdrom_dir); };
|
||
option "Device", action
|
||
{ msg_prompt (MSG_dev, cdrom_dev, cdrom_dev, SSTRSIZE); };
|
||
option "R<>pertoire", action
|
||
{ msg_prompt (MSG_dir, cdrom_dir, cdrom_dir, STRSIZE); };
|
||
option "Continue", exit;
|
||
|
||
menu cdrombadmount, title " Que voulez-vous faire?";
|
||
option "R<>essayer", exit, sub menu cdromsource, action
|
||
{ yesno = 1; ignorerror = 0; };
|
||
option "Abandonner", exit, action
|
||
{ yesno = 0; ignorerror = 0; };
|
||
option "Ignorer les erreurs, continuer quand m<>me", exit, action
|
||
{ yesno = 1; ignorerror = 1; };
|
||
|
||
menu localfssource, title " Changer";
|
||
display action
|
||
{ msg_display (MSG_localfssource, localfs_dev, localfs_fs, localfs_dir); };
|
||
option "Device", action
|
||
{ msg_prompt (MSG_dev, localfs_dev, localfs_dev, SSTRSIZE); };
|
||
option "Syst<73>me de fichier", action
|
||
{ msg_prompt (MSG_filesys, localfs_fs, localfs_fs, STRSIZE); };
|
||
option "R<>pertoire", action
|
||
{ msg_prompt (MSG_dir, localfs_dir, localfs_dir, STRSIZE); };
|
||
option "Continuer", exit;
|
||
|
||
menu localfsbadmount, title " Que voulez vous faire?";
|
||
option "R<>essayer", exit, sub menu localfssource, action
|
||
{ yesno = 1; ignorerror = 0; };
|
||
option "Abandonner", exit, action
|
||
{ yesno = 1; ignorerror = 0; };
|
||
option "Ignorer les erreurs, continuer quand m<>me", exit, action
|
||
{ yesno = 1; ignorerror = 1; };
|
||
|
||
menu localdirsource, title "Changer";
|
||
display action
|
||
{ msg_display(MSG_localdir, localfs_dir); };
|
||
option "R<>pertoire", action
|
||
{ msg_prompt (MSG_dir, localfs_dir, localfs_dir, STRSIZE); },
|
||
exit;
|
||
option "Continuer", exit;
|
||
|
||
menu localdirbad, title " Que voulez vous faire?";
|
||
option "Changer le chemin d'acc<63>s", action
|
||
{ yesno = 1;
|
||
msg_prompt(MSG_localdir, localfs_dir, localfs_dir, STRSIZE);
|
||
}, exit;
|
||
option "Abandonner", exit, action
|
||
{ yesno = 0; ignorerror = 0; };
|
||
option "Ignorer les erreurs, continuer quand m<>me", exit, action
|
||
{ yesno = 1; ignorerror = 1; };
|