.\" $NetBSD: 7.t,v 1.3 2003/08/07 10:30:55 agc Exp $
|
|
.\"
|
|
.\" Copyright (c) 1983, 1986, 1993
|
|
.\" The Regents of the University of California. All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\" 3. Neither the name of the University nor the names of its contributors
|
|
.\" may be used to endorse or promote products derived from this software
|
|
.\" without specific prior written permission.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
.\" SUCH DAMAGE.
|
|
.\"
|
|
.\" @(#)7.t 8.1 (Berkeley) 6/8/93
|
|
.\"
|
|
.nr H2 1
|
|
.br
|
|
.ne 30v
|
|
.\".ds RH "Socket/protocol interface
|
|
.NH
|
|
\s+2Socket/protocol interface\s0
|
|
.PP
|
|
The interface between the socket routines and the communication
|
|
protocols is through the \fIpr_usrreq\fP routine defined in the
|
|
protocol switch table. The following requests to a protocol
|
|
module are possible:
|
|
.DS
|
|
._d
|
|
#define PRU_ATTACH 0 /* attach protocol */
|
|
#define PRU_DETACH 1 /* detach protocol */
|
|
#define PRU_BIND 2 /* bind socket to address */
|
|
#define PRU_LISTEN 3 /* listen for connection */
|
|
#define PRU_CONNECT 4 /* establish connection to peer */
|
|
#define PRU_ACCEPT 5 /* accept connection from peer */
|
|
#define PRU_DISCONNECT 6 /* disconnect from peer */
|
|
#define PRU_SHUTDOWN 7 /* won't send any more data */
|
|
#define PRU_RCVD 8 /* have taken data; more room now */
|
|
#define PRU_SEND 9 /* send this data */
|
|
#define PRU_ABORT 10 /* abort (fast DISCONNECT, DETATCH) */
|
|
#define PRU_CONTROL 11 /* control operations on protocol */
|
|
#define PRU_SENSE 12 /* return status into m */
|
|
#define PRU_RCVOOB 13 /* retrieve out of band data */
|
|
#define PRU_SENDOOB 14 /* send out of band data */
|
|
#define PRU_SOCKADDR 15 /* fetch socket's address */
|
|
#define PRU_PEERADDR 16 /* fetch peer's address */
|
|
#define PRU_CONNECT2 17 /* connect two sockets */
|
|
/* begin for protocols internal use */
|
|
#define PRU_FASTTIMO 18 /* 200ms timeout */
|
|
#define PRU_SLOWTIMO 19 /* 500ms timeout */
|
|
#define PRU_PROTORCV 20 /* receive from below */
|
|
#define PRU_PROTOSEND 21 /* send to below */
|
|
.DE
|
|
A call on the user request routine is of the form,
|
|
.DS
|
|
._f
|
|
error = (*protosw[].pr_usrreq)(so, req, m, addr, rights);
|
|
int error; struct socket *so; int req; struct mbuf *m, *addr, *rights;
|
|
.DE
|
|
The mbuf data chain \fIm\fP is supplied for output operations
|
|
and for certain other operations where it is to receive a result.
|
|
The address \fIaddr\fP is supplied for address-oriented requests
|
|
such as PRU_BIND and PRU_CONNECT.
|
|
The \fIrights\fP parameter is an optional pointer to an mbuf
|
|
chain containing user-specified capabilities (see the \fIsendmsg\fP
|
|
and \fIrecvmsg\fP system calls). The protocol is responsible for
|
|
disposal of the data mbuf chains on output operations.
|
|
A non-zero return value gives a
|
|
UNIX error number which should be passed to higher level software.
|
|
The following paragraphs describe each
|
|
of the requests possible.
|
|
.IP PRU_ATTACH
|
|
.br
|
|
When a protocol is bound to a socket (with the \fIsocket\fP
|
|
system call) the protocol module is called with this
|
|
request. It is the responsibility of the protocol module to
|
|
allocate any resources necessary.
|
|
The ``attach'' request
|
|
will always precede any of the other requests, and should not
|
|
occur more than once.
|
|
.IP PRU_DETACH
|
|
.br
|
|
This is the antithesis of the attach request, and is used
|
|
at the time a socket is deleted. The protocol module may
|
|
deallocate any resources assigned to the socket.
|
|
.IP PRU_BIND
|
|
.br
|
|
When a socket is initially created it has no address bound
|
|
to it. This request indicates that an address should be bound to
|
|
an existing socket. The protocol module must verify that the
|
|
requested address is valid and available for use.
|
|
.IP PRU_LISTEN
|
|
.br
|
|
The ``listen'' request indicates the user wishes to listen
|
|
for incoming connection requests on the associated socket.
|
|
The protocol module should perform any state changes needed
|
|
to carry out this request (if possible). A ``listen'' request
|
|
always precedes a request to accept a connection.
|
|
.IP PRU_CONNECT
|
|
.br
|
|
The ``connect'' request indicates the user wants to a establish
|
|
an association. The \fIaddr\fP parameter supplied describes
|
|
the peer to be connected to. The effect of a connect request
|
|
may vary depending on the protocol. Virtual circuit protocols,
|
|
such as TCP [Postel81b], use this request to initiate establishment of a
|
|
TCP connection. Datagram protocols, such as UDP [Postel80], simply
|
|
record the peer's address in a private data structure and use
|
|
it to tag all outgoing packets. There are no restrictions
|
|
on how many times a connect request may be used after an attach.
|
|
If a protocol supports the notion of \fImulti-casting\fP, it
|
|
is possible to use multiple connects to establish a multi-cast
|
|
group. Alternatively, an association may be broken by a
|
|
PRU_DISCONNECT request, and a new association created with a
|
|
subsequent connect request; all without destroying and creating
|
|
a new socket.
|
|
.IP PRU_ACCEPT
|
|
.br
|
|
Following a successful PRU_LISTEN request and the arrival
|
|
of one or more connections, this request is made to
|
|
indicate the user
|
|
has accepted the first connection on the queue of
|
|
pending connections. The protocol module should fill
|
|
in the supplied address buffer with the address of the
|
|
connected party.
|
|
.IP PRU_DISCONNECT
|
|
.br
|
|
Eliminate an association created with a PRU_CONNECT request.
|
|
.IP PRU_SHUTDOWN
|
|
.br
|
|
This call is used to indicate no more data will be sent and/or
|
|
received (the \fIaddr\fP parameter indicates the direction of
|
|
the shutdown, as encoded in the \fIsoshutdown\fP system call).
|
|
The protocol may, at its discretion, deallocate any data
|
|
structures related to the shutdown and/or notify a connected peer
|
|
of the shutdown.
|
|
.IP PRU_RCVD
|
|
.br
|
|
This request is made only if the protocol entry in the protocol
|
|
switch table includes the PR_WANTRCVD flag.
|
|
When a user removes data from the receive queue this request
|
|
will be sent to the protocol module. It may be used to trigger
|
|
acknowledgements, refresh windowing information, initiate
|
|
data transfer, etc.
|
|
.IP PRU_SEND
|
|
.br
|
|
Each user request to send data is translated into one or more
|
|
PRU_SEND requests (a protocol may indicate that a single user
|
|
send request must be translated into a single PRU_SEND request by
|
|
specifying the PR_ATOMIC flag in its protocol description).
|
|
The data to be sent is presented to the protocol as a list of
|
|
mbufs and an address is, optionally, supplied in the \fIaddr\fP
|
|
parameter. The protocol is responsible for preserving the data
|
|
in the socket's send queue if it is not able to send it immediately,
|
|
or if it may need it at some later time (e.g. for retransmission).
|
|
.IP PRU_ABORT
|
|
.br
|
|
This request indicates an abnormal termination of service. The
|
|
protocol should delete any existing association(s).
|
|
.IP PRU_CONTROL
|
|
.br
|
|
The ``control'' request is generated when a user performs a
|
|
UNIX \fIioctl\fP system call on a socket (and the ioctl is not
|
|
intercepted by the socket routines). It allows protocol-specific
|
|
operations to be provided outside the scope of the common socket
|
|
interface. The \fIaddr\fP parameter contains a pointer to a static
|
|
kernel data area where relevant information may be obtained or returned.
|
|
The \fIm\fP parameter contains the actual \fIioctl\fP request code
|
|
(note the non-standard calling convention).
|
|
The \fIrights\fP parameter contains a pointer to an \fIifnet\fP structure
|
|
if the \fIioctl\fP operation pertains to a particular network interface.
|
|
.IP PRU_SENSE
|
|
.br
|
|
The ``sense'' request is generated when the user makes an \fIfstat\fP
|
|
system call on a socket; it requests status of the associated socket.
|
|
This currently returns a standard \fIstat\fP structure.
|
|
It typically contains only the
|
|
optimal transfer size for the connection (based on buffer size,
|
|
windowing information and maximum packet size).
|
|
The \fIm\fP parameter contains a pointer
|
|
to a static kernel data area where the status buffer should be placed.
|
|
.IP PRU_RCVOOB
|
|
.br
|
|
Any ``out-of-band'' data presently available is to be returned. An
|
|
mbuf is passed to the protocol module, and the protocol
|
|
should either place
|
|
data in the mbuf or attach new mbufs to the one supplied if there is
|
|
insufficient space in the single mbuf.
|
|
An error may be returned if out-of-band data is not (yet) available
|
|
or has already been consumed.
|
|
The \fIaddr\fP parameter contains any options such as MSG_PEEK
|
|
to examine data without consuming it.
|
|
.IP PRU_SENDOOB
|
|
.br
|
|
Like PRU_SEND, but for out-of-band data.
|
|
.IP PRU_SOCKADDR
|
|
.br
|
|
The local address of the socket is returned, if any is currently
|
|
bound to it. The address (with protocol specific format) is returned
|
|
in the \fIaddr\fP parameter.
|
|
.IP PRU_PEERADDR
|
|
.br
|
|
The address of the peer to which the socket is connected is returned.
|
|
The socket must be in a SS_ISCONNECTED state for this request to
|
|
be made to the protocol. The address format (protocol specific) is
|
|
returned in the \fIaddr\fP parameter.
|
|
.IP PRU_CONNECT2
|
|
.br
|
|
The protocol module is supplied two sockets and requested to
|
|
establish a connection between the two without binding any
|
|
addresses, if possible. This call is used in implementing
|
|
the
|
|
.IR socketpair (2)
|
|
system call.
|
|
.PP
|
|
The following requests are used internally by the protocol modules
|
|
and are never generated by the socket routines. In certain instances,
|
|
they are handed to the \fIpr_usrreq\fP routine solely for convenience
|
|
in tracing a protocol's operation (e.g. PRU_SLOWTIMO).
|
|
.IP PRU_FASTTIMO
|
|
.br
|
|
A ``fast timeout'' has occurred. This request is made when a timeout
|
|
occurs in the protocol's \fIpr_fastimo\fP routine. The \fIaddr\fP
|
|
parameter indicates which timer expired.
|
|
.IP PRU_SLOWTIMO
|
|
.br
|
|
A ``slow timeout'' has occurred. This request is made when a timeout
|
|
occurs in the protocol's \fIpr_slowtimo\fP routine. The \fIaddr\fP
|
|
parameter indicates which timer expired.
|
|
.IP PRU_PROTORCV
|
|
.br
|
|
This request is used in the protocol-protocol interface, not by the
|
|
routines. It requests reception of data destined for the protocol and
|
|
not the user. No protocols currently use this facility.
|
|
.IP PRU_PROTOSEND
|
|
.br
|
|
This request allows a protocol to send data destined for another
|
|
protocol module, not a user. The details of how data is marked
|
|
``addressed to protocol'' instead of ``addressed to user'' are
|
|
left to the protocol modules. No protocols currently use this facility.
|