…
|
||
---|---|---|
.. | ||
fpsp.o.uu | ||
fpspnull.s | ||
README | ||
README_FIRST | ||
README.source |
SECTION 1 FLOATING POINT SOFTWARE PACKAGE TERMS. From: Microprocessor & Memory Technologies Group Semiconductor Products Sector 6501 William Cannon Drive West, Mail Station OE33, Austin, Texas 78735-8598 To: FLOATING POINT SOFTWARE PACKAGE USERS Date: August 27, 1993 1.1 TITLE TO FLOATING POINT SOFTWARE PACKAGE FPSP Title to the 68040 Floating Point Software Package, all copies thereof (in whole or in part and in any form), and all rights therein, including all rights in patents, and copyrights, applicable thereto, shall remain vested in MOTOROLA. All rights, title and interest in the resulting modifications belong to MOTOROLA except where such modifications (a) are made solely for use with computer systems manufactured or distributed by user; (b) are themselves copyrightable; and (c) would not constitute a copyright infringement if not licensed hereunder. 1.2 DISCLAIMER OF WARRANTY. THE 68040 FLOATING POINT SOFTWARE PACKAGE is provided on an "AS IS" basis and without other warranty except as stated herein. IN NO EVENT SHALL MOTOROLA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM USE OF THE 68040 FLOATING POINT SOFTWARE PACKAGE. THIS DISCLAIMER OF WARRANTY EXTENDS TO ALL USERS OF THE THE 68040 FLOATING POINT SOFTWARE PACKAGE AND IS IN LIEU OF ALL WARRANTIES WHETHER EXPRESS, IMPLIED, OR STATUTORY, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. SECTION 2 Release 2.3 Errata As of this release, the following may be considered an errata of the 040 (Mask 20D43B Mask 4D50D and Mask 5D98D) FPSP: 1. INEX1 reported by inexact conversion of packed source operand for a dyadic instruction will not be reported by the 040 upon completion of that instruction. This errata corresponds to errata "F5" on the 68040 Errata Sheet. Fixed in D98D. 2. FREM and FMOD with packed operands will occasionally differ from the 881/2 results by one ulp in the conversion of the packed source operand. 3. INEX2/AINEX are not calculated in the same manner as in the 881/882 for some cases in which the result is overflowed. Currently, if the operation was an integer move-out, INEX2/AINEX is not set for any case. In some cases of fscale with integer input, the INEX2 bit will not be set on inex calculation. Under extended rounding precision, FSCALE results which underflow and are inexact may be incorrectly rounded. Inaddition, INEX2 is not signaled in these cases. 4. If an Fmove FPn,FPM(this also applies to the FNEG and FABS), is preceded by any floating point operation with a denorm source operand , the FMOVE destination (FPm) is incorrectly tagged and may result in silent data corruption. A software fix in release 2.2. SECTION 3 Software Specification for an MC68040 Floating- Point Software Package The purpose of this section is to provide an overview of the floating-point software package (FPSP) for the MC68040. The FPSP emulates the floating-point instructions of the MC68881/MC68882 which are not provided by the MC68040. 3.1 DEFINITIONS, ACRONYMS, AND ABBREVIATIONS FPn - Floating-Point Data Register Source FPSP - Floating-Point Software Package FPU - Floating-Point Unit FPx - Floating-Point Data Register See the Glossary of Reference 1 for additional definitions. 3.2 PRODUCT OVERVIEW The FPSP adds additional floating-point capabilities to the MC68040. A subset of the MC6888x instruction set is executed by the MC68040 on-chip FPU. The remaining floating-point instructions are emulated in software by the FPSP (see Reference 2). There are two types of FPSP: one for applications compiled for the MC68881/MC68882 and another for applications compiled for the MC68040 (see 3.8.2 Packaging). The FPSP provides: * Arithmetic and Transcendental Instructions * Decimal Conversions * Exception Handlers * MC68040 Unimplemented Data Type and Data Format Handlers There are two types of users: 1) end users who are running applications and 2) system integrators who will install the package (see 3.8.3 Site Adaptations). 3.3 GENERAL CONSTRAINTS The FPSP satisfies the requirements of the ANSI IEEE Standard for Binary Floating-Point Arithmetic 754. The FPSP runs old user code unchanged and is transparent for old code. The FPSP is easy to modify and install. The performance of the transcendental function routines is equivalent or superior to that of a 33-MHz MC68881/MC68882. The error bound is equivalent or superior to the MC68881/MC68882 (see 3.7.2 Accuracy). 3.4 ASSUMPTIONS AND DEPENDENCIES The FPSP can be installed into any operating system. The MC68040 FPU shall be implemented as described in Reference 2. Table 3-1 Lists the functions provided by the MC68040. 3.5.2 Exceptions The main goal of the FPSP exception handlers is to provide the user with an easy path to port over existing MC68882 exception handlers for use with the MC68040. The end result is that the FPSP provides an entry point so that once this point is reached, there is an indication that an IEEE-defined trap condition exist. 3.5.2.1 BSUN <20> BRANCH/SET ON UNORDERED. On a trap-enabled condition, the FPSP updates the floating-point instruction address register (FPIAR) by copying the PC value in the pre-instruction stack frame to the FPIAR. Once this is done, the exceptional frame is restored without clearing the exception, and the program flow goes to the FPSP provided entry point. At the entry point the MC68040 is in an exceptional state, ready to execute the user-supplied exception handler. 3.5.2.2 SNAN <20> SIGNALING NOT-A-NUMBER. On a trap-disabled condition, and if the destination format is B, W,or L, then the FPSP stores the most significant 8, 16, or 32 bits, respectively, of the SNAN mantissa, with the SNAN bit set, to the destination. The FPSP discards the exceptional frame, then returns to the main program flow without entering the FPSP provided entry point, hence the user-provided exception handler is not executed. On a trap-enabled condition, the FPSP checks if the destination format is B, W, or L. Then, the FPSP stores the most significant 8, 16, or 32 bits, respectively, of the SNAN mantissa, with the SNAN bit set, to the destination. The FPSP then restores the exceptional frame without clearing the exception, and branches to the FPSP provided entry point. At the entry point, the MC68040 is in an exceptional state, ready to execute the user- supplied exception handler. 3.5.2.3 OPERR <20> OPERAND ERROR. This exception traps through vector number 52. Table 3-3 shows the operand errors generated by the MC68040. Table 3-4 shows the operand errors generated by the FPSP. Note that the FPSP Unimplemented Instruction Handler detects and adds to the cases in which OPERR exceptions occur. Refer to Table 3-4 for these specific exception- causing conditions. On a trap-disabled condition, the FPSP checks if the operand error is caused by an FMOVE to a B, W, or L memory or integer data register destination. If it is caused by an integer overflow or if the floating-point data register to be stored contains infinity, the FPSP stores the largest positive or negative integer that can fit in the specified destination format size. If the destination is integer and the floating-point number to be stored is a NAN, then the 8, 16, or 32 most significant bits of the NAN significand is stored as a result. Next the FPSP checks for a false OPERR condition for an FMOVE to memory or integer data register. This condition occurs if the operand is equal to the largest negative integer representable in its format. The FPSP then stores the proper result, discards the exceptional frame, and returns to the main program flow without executing the user-supplied exception handler. On a trap-enabled condition, the FPSP does the same functions as the above trap-disabled condition, with the exception that in the end, the FPSP restores the exceptional frame without clearing the exception and branches to the FPSP supplied entry point instead of returning to the main program flow. At the FPSP supplied entry point, the MC68040 is in an exceptional state, ready to execute the user-supplied exception handler. 3.5.2.4 OVFL <20> OVERFLOW. This exception traps through vector number 53. On a trap-disabled case, the FPSP stores the result in the destination as determined by the rounding mode at the destination as follows: Rounding Mode Result RN Infinity, with the sign of the intermediate result RZ Largest magnitude number, with the sign of the intermediate result. RM For positive overflow, largest positive number For negative overflow, infinity RP For positive overflow, infinity For negative overflow, largest negative number The FPSP then clears the appropriate exception bit in the frame and restores the non-exceptional frame into the MC68040, and then returns to the main program flow. On a trap-enabled case, the FPSP actions are identical to those found in the trap-disabled case, with the exception that instead of restoring a non-exceptional frame, the original exceptional frame is restored to the MC68040 and the FPSP branches to the FPSP supplied entry point. At this entry point, the MC68040 is in an exceptional state, ready to execute the user-supplied exception handler. 3.5.2.5 UNFL <20> UNDERFLOW. This exception traps through vector number 51. On a trap-disabled case, the FPSP stores the result in the destination as determined by the rounding mode at the destination as follows: RN Zero with the sign of the intermediate result. RZ Zero with the sign of the intermediate result. RM For positive underflow, +zero. For negative underflow, the smallest denormalized negative number. RP For positive underflow, the smallest denormalized positive number. For negative underflow, -zero. The FPSP then clears the appropriate exception bit in the frame and restores the non-exceptional frame into the MC68040, and then returns to the main program flow. On a trap-enabled case, the FPSP actions are identical to those found in the trap-disabled case, with the exception that instead of restoring a non-exceptional frame, the original exceptional frame is restored to the MC68040 and the FPSP branches to the FPSP supplied entry point. At this entry point, the MC68040 is in an exceptional state, ready to execute the user-supplied exception handler. 3.5.2.6 DZ <20> DIVIDE BY ZERO. Note that the FPSP Unimplemented Instruction Handler detects and adds to the cases in which DZ exceptions occur. Refer to Table 3-5 for these specific exception-causing conditions. Table 3-6 lists the DZ exceptions generated by the MC68040. The FPSP is not needed for this exception. The user- supplied exception handler is always entered. A system call is provided by the FPSP to calculate the exceptional operand. 3.5.2.7 INEX1/INEX2 <20> INEXACT RESULT 1/2. Note that the FPSP Unimplemented Instruction Handler detects and allows INEX1 exceptions to occur. Furthermore, many new cases of INEX2 exceptions may be generated by the FPSP Unimplemented Instruction Handler as well. The INEX1 exception traps into this handler as well as INEX2 exceptions. The FPSP is not needed for this exception. The user- supplied exception handler is always entered. 3.5.3 Instructions The following paragraphs describe the arithmetic and transcendental instructions supported by the FPSP. 3.5.3.1 ARITHMETIC. Table 3-7 shows the arithmetic instructions supported by the FPSP. 3.5.3.2 TRANSCENDENTAL. Table 3-8 shows the transcendental instructions supported by the FPSP. 3.6 EXTERNAL INTERFACE REQUIREMENTS For end users the FPSP is transparent; system Integrators will integrate the FPSP into their system. (See 3.8.3. Site Adaptations) For applications compiled for the MC68881/MC68882 the FPSP provides kernel routines to support the MC68040 unimplemented instructions. The MC68040 uses vector number 11 for the unimplemented instructions. The MC68040 stack frames are different for unimplemented MC68881/MC68882 instructions and other F-line traps. For applications compiled for the MC68040 the unimplemented instructions are contained in a library (to avoid the F_line trap overhead at runtime). For both applications the FPSP provides kernel routines to support exceptions (vectors 48<34>54) and unsupported data types (vector 55). 3.7 PERFORMANCE REQUIREMENTS The following paragraphs describe the speed, accuracy, and compatibility requirements for the FPSP. 3.7.1 Speed The performance of the transcendental function routines is equivalent or superior to that of a 33-MHz MC68881/MC68882. 3.7.2 Accuracy The following paragraphs describe the arithmetic instructions, transcendental instructions, and decimal conversions for the FPSP. 3.7.2.1 ARITHMETIC INSTRUCTIONS. The error bound is one-half unit in the last place of the destination format in the round-to-nearest mode, and one unit in the last place in the other rounding modes. 3.7.2.2 TRANSCENDENTAL INSTRUCTIONS. The error bound is less than 0.502 ulp of double precision. 3.7.2.3 DECIMAL CONVERSIONS. The error bound is 0.97 unit in the last digit of the destination precision for the round-to-nearest mode; and 1.47 units in the last digit of the destination precision for the other rounding modes. 3.7.3 Compatibility The FPSP transcendental calculation results are not the same as for the MC68881/MC68882. This is because the algorithms used by the MC68881/MC68882 (CORDIC) cannot be effectively implemented in software. All other calculations are identical. The error bound is equivalent or superior to the MC68881/MC68882. 3.8 OTHER REQUIREMENTS The following paragraphs describe other requirements for the FPSP, such as maintainability, packaging, and site adaptations. 3.8.1 Maintainability The speed requirements have forced writing most of the package in assembly language. 3.8.2 Packaging There are two versions of the FPSP. The FPSP Kernel Version is used to execute pre-existing user object code written for the MC68882. This is installed as part of the operating system. User applications need not be recompiled or modified in any way once the FPSP Kernel Version is installed. The FPSP Library Version is used to compile code that uses only the MC68040-implemented floating point instructions. The library version provides less overhead than the FPSP Kernel Version. Other features of this library includes ABI compliance as well as IEEE exception-reporting compliant. It is not however, UNIX exception-reporting compliant. The FPSP is not yet available in library format. 3.8.3 Site Adaptations Some of the entries in the vector table needs to point to entry points within the FPSP Kernel Version. For those vectors the FPSP displaces, an entry point is provided to replace that which it takes. Note that former MC68882 floating-point exception handlers need to go through minor modifications to account for the differences between the MC68040 and MC68882 floating point exceptional state frames. The FPSP provides skeleton code for each floating- point exception handler to aid in porting the MC68882 floating-point exception handlers. For systems and applications that never set any of the exception bits in the FPCR, or if the former MC68882 floating-point exception handlers only contain minimum code needed to clear the exception and return, no work is needed and the FPSP is a drop-in package. The FPSP Library Version needs to "intercept" the appropriate math library calls which use MC68882 transcendental instructions. Since each site has different naming conventions, the FPSP subroutines need to be renamed accordingly and recompiled. The resident compiler also needs to provide a library path search pattern such that the FPSP is given a chance to resolve those trancendentals instructions. 3.8.4 Stack Area Usage To achieve code re-entrace, the FPSP allocates context- sensitive variables on the stack. The FPSP does not require more than 512 bytes on the stack per context. This may be an installation concern for UNIX applications in which there is a limited UBLOCK area, and that the system stack resides there. 3.8.5 ROM-based applications One of the goals of the FPSP Kernel Version is to be able to fit in a read-only space of no more than 64 KBytes. There are two main sections that need to reside in ROM. The text section, and the initialized data section. The text section accounts for 65% while the initialized data section accounts for 35%. 3.9 FPSP KERNEL VERSION INSTALLATION NOTES The following paragraphs provide the MC68882 users with an understanding of the issues involved in porting over the FPSP into existing MC68030/MC68882 systems. Once these issues are understood, then the actual installation is explained. 3.9.1 Differences between the MC68040 and MC68882 Floating-point Exception Handling The main reason for providing the FPSP is to provide MC68882 compatibility. If the installer understands the main differences between the MC68882 and MC68040 in the area of floating-point exception handlers, skip this section and go to the next section. There are three areas that differ between the MC68040 and MC68882. The first difference is that of unimplemented instructions. The FPSP handles this by means of the F-line exception handling. This means that if there is an existing F-line handler, the FPSP replaces the existing F- line exception handler, but provides an alternate entry point for the existing F-line handler. The second difference is unsupported data types. The MC68040 provides a new entry point in the vector table, therefore no existing handler is replaced by the FPSP. There are no installation issues here. The third difference is that of floating point exception differences. This issue is more involved and requires further explanations. The IEEE standard allows the user to enable or disable each floating point exception individually. If an exceptional condition occurs, the IEEE defines a specific action for the trap-disabled condition, and it also defines certain specific actions for a trap-enabled condition. The IEEE standard however, does not constrain the implementation of exception handling; both software and hardware can be used. The MC68882 supports the IEEE exception handling compliance totally in hardware. For example, a user- disabled (trap disabled) exception will cause the specified IEEE defined actions for user-disabled exception handling to occur. Similarly, user-enabled exceptions will cause the MC68882 to take the exception as defined by the IEEE trap enabled case. The MC68040 provides full IEEE trap-disabled exception handling compliance for the INEX and DZ exceptions. Just as the MC68882, the MC68040 takes these exceptions only for an IEEE trap-enabled condition. Existing MC68882 handlers have a minimum code requirement as defined by the MC68882 User's Manual. As the MC68882 handlers, the MC68040 handlers have a minimum code requirement as well. The FPSP provides this minimum code requirement. The MC68040 does not provide full IEEE exception compliance on IEEE defined trap-disabled conditions for the following exceptions: OVFL, UNFL, OPERR, SNAN. For these exceptions, the MC68040 may take an exception even on an IEEE-defined trap-disabled condition. The FPSP provided exception handlers decide if its job is to implement IEEE trap-disabled exception compliance, (and therefore not execute the user supplied exception handler) or to implement IEEE trap-enabled exception compliance, (hence executing the user supplied exception handler). The FPSP provides a user entry point so that when this entry point is taken an IEEE-defined trap-enabled condition has definitely occurred. At this specified entry point, an exception handler written for the MC68882 needs to be modified to account for MC68040 stack differences, and then placed at the user entry point. As with the MC68882, there is a minimum code requirement for the MC68040 handler, but this minimum code is provided by the FPSP. From an installation perspective, the OVFL, UNFL, OPERR, SNAN exception handlers are replaced by the FPSP handlers, but the FPSP provides an entry point so that MC68882-like exception handlers may be written. Furthermore, minimum code is provided by the FPSP and can be used as a template. The BSUN exception is different in that unlike the previous exception handlers, the difference between the MC68882 and MC68040 resides in the IEEE-defined trap enabled case. The FPSP handles this by performing the patch needed for MC68882 compatibility, and then restoring the exception to the MC68040 without performing the necessary steps to clear the BSUN exception. The exceptional frame is restored into the MC68040 and the FPSP branches to the user entry point provided. At this entry point, an MC68882-like exception handler written for the MC68040 is executed without having to worry about the built-in incompatibility. Although this method incurs a performance hit, it frees the user-defined exception handler from having to write the code needed to implement MC68882 code compatibility. As with the other exception handlers, the FPSP provides the minimum code needed. In summary, the FPSP replaces the following exception handlers and provides an entry-point for MC68882-like exception handlers for these exceptions: OVFL, UNFL, OPERR, SNAN, BSUN, F-line. The FPSP is not needed for the INEX and DZ exception handlers, and these exception handlers just need to be MC68882-like. 3.9.2 Vector Table The entry point into the FPSP is achieved by having the appropriate vector table offset point to a specified entry point within the FPSP. For simplicity, all of the FPSP main entry points are found in the file skeleton.sa. Table 3-9 shows the vector table offset and the appropriate labels within the file skeleton.sa that it needs to point to. Figure 3-1 shows a flowchart of the entry points. Once the entry point is reached, the user may add some user-specific code prior to jumping to the FPSP routines ( FPSP routines are prefixed by "fpsp_"). After the jump to the FPSP routines, the FPSP performs its function and then jumps to the FPSP supplied entry points (if needed) found in the file skeleton.sa. 3.9.3 FPSP Supplied Entry Points To replace the vector table entries it displaces, the FPSP provides an alternate entry point. For simplicity, all of the FPSP supplied entry points are found in the file skeleton.sa. The FPSP supplied F-line exception entry point is straight-forward. An F-line exception handler written for an MC68030 can be placed here without modifications. The Unsupported Data Type exception handler is newly-defined, it does not displace any MC68030/MC68882 exception handler. Therefore, the FPSP does not provide an alternate entry point for this exception. The alternate entry points have the naming convention such that the specified exception handler is prefixed by "real_". For instance, the entry point for user-supplied BSUN exception handler is named "real_bsun". For the floating-point exception handlers (BSUN, OPERR, SNAN, DZ, OVFL, and UNFL) previously written for an MC68882 based system, these handlers need to be modified slightly for use with the MC68040. Once these handlers are modified, they are then placed in the FPSP provided entry points. 3.9.4 Extract the Hardware Independent portion of the MC68882 handlers To modify the existing MC68882 handlers, all of the code used in accessing the MC68882 generated frame needs to be stripped off. The code used in clearing an MC68882 exception (setting bit 27 of the BIU Flag) needs to be stripped off as well. Only the hardware independent portions of the MC68882 handlers may be used. To aid the installer in rewriting the MC68882 exception handlers, the file skeleton.sa provides the minimum code necessary to clear the exception once the specific handler is entered. Once the hardware-independent portion is written, the modified MC68882 handlers need to be integrated into the portion of the code which is hardware dependent. The minimum code needed by each exception handler is already provided by the FPSP within the file skeleton.sa. The following section describes the mechanics behind the written code. 3.9.5 MC68040 Minimum Exception Code This section describes the minimum requirements for the user-supplied exception handlers. As mentioned in the previous sections, these minimum handlers are provided as part of the package, and this section is strictly for the user's information only. As with the MC68882, if all exceptions are always disabled, no minimum code is necessary since the FPSP guarantees that these FPSP provided entry points are never entered on trap-disabled condition. Therefore, for existing systems that do not provide exception handlers for the MC68882, it is likely that the assumption that all exceptions are always disabled is valid, and therefore no user-defined MC68040 exception handlers are needed either. The above paragraph should not be interpreted to mean that the FPSP provided exception handlers are unnecessary. On the contrary, the FPSP provided exception handlers are needed, and that these FPSP exception handlers provide the entry points for user-defined exception handlers. Whether or not the user-defined MC68040 exception handers are needed is the issue being discussed. Assuming that it is possible that the exceptions are enabled at some point, the minimum exception handler is similar to that defined for an MC68882. As with the MC68882, the MC68040 requires that the first floating point instruction be an FSAVE. Unlike the MC68882, the MC68040 does not always require an equivalent FRESTORE. For an E1 exception, only the FSAVE requirement is needed, the state frame may be discarded. The E3 exception is more similar to that found in an MC68882. As with the MC68882, the E3 exception requires an FSAVE, an instruction that clears the exception in the resulting FSAVE stack, followed by an FRESTORE. If both E3 and E1 exceptions exist at the same time, then the exception is handled as though it were an E3 exception. After which, the MC68040 re-traps to handle the E1 exception. The E3 exception can only be reported by the following exception handlers: OVFL, UNFL, INEX. For these exception handlers, this is the minimum code requirement: 1) FSAVE 2) if E3 bit set, goto (4), else goto (3) 3) E1 exception, throw away stack and RTE 4) Clear E3 bit, FRESTORE, RTE The E3 exception cannot be reported by the following exception handlers: SNAN, OPERR and DZ. Since only an E1 exception needs to be handled here, this is the minimum code requirement: 1) FSAVE 2) throw away stack and RTE For the BSUN exception handler, the minimum code requirement is: 1) FSAVE 2) Do one of 4 methods described in MC68040 User's Manual 3) throw away stack and RTE If the above minimum code requirements are not met, then, an infinitely looping exception sequence occurs. 3.9.6 Mem_read and Mem_write The mem_write and mem_read subroutines are used by the FPSP to read and write from user space. These routines perform a UNIX system call to lcopyin and lcopyout. The FPSP provides a simple version of lcopyin and lcopyout for non-UNIX applications. Installation to UNIX-based systems requires that the FPSP provided lcopyin and lcopyout be deleted or commented out. For simplicity, these subroutines are found in the file skeleton.sa. The production version of the FPSP is fully re-entrant. If a page fault occurs on either a mem_read or mem_write, the operating system may perform a page-in operation and still allow other processes to use the FPSP. 3.9.7 Increasing F-line Handler Performance The FPSP was written to handle all possible cases of MC68040 vs MC68030/MC68882 problem areas. Any performance improvement in this handler increases floating-point performance. The F-line handling may be made quicker by pointing the vector table entry directly into the label "fpsp_unimp" found in the file x_unimp.sa, if these conditions are met: 1) That the system never has to execute an FMOVECR instruction in which bits 0 to 5 of the F-line word are non-zero. 2) An alternate F-line entry point is unnecessary. This optimization saves a total of three instructions. ( 1 bra, 1 cmpi, 1 beq). 3.10 REFERENCES 1. MC68881UM/AD, MC68881/MC68882 Motorola Floating-Point Coprocessor User's Manual. Motorola Inc., 1989 2. M68040UM/AD M68040 32-Bit Microprocessor User's Manual, Motorola, Inc.,1992, 3. MC68020UM/AD, MC68020 32-Bit Microprocessor User's Manual, Motorola, Inc., 1990. 4. MC68030UM/AD, MC68030 Enhanced 32-Bit Microprocessor User's Manual, Motorola Inc., 1990 5. ANSI/IEEE Std. 754,1985 Standard for Binary Floating- Point Arithmetic 6. M68000PM/AD REV. 1 Programmer's Reference Manual. Motorola Inc., 1992 3.11 Tables and Figures Table 3-1. Functions Provided by MC68040 ------------------------------------------------------------------ Name | Description ------------------------------------------------------------------ FMOVE Move to FPU FMOVEM Move Multiple Registers FSMOVE Single-Precision Move FDMOVE Double-Precision Move FCMP Compare FABS Absolute Value FSABS Single-Precision Absolute Value FDABS Double-Precision Absolute Value FTST Test FNEG Negate FSNEG Single-Precision Negate FDNEG Double-Precision Negate FADD Add FSUB Subtract FDIV Divide FMUL Multiply FBcc Branch Conditionally FScc Set According to Condition FDBcc Test Cond, Dec and Branch FTRAPcc Trap Conditionally FSADD Single-Precision Add FSSUB Single-Precision Subtract FSMUL Single-Precision Multiply FSDIV Single-Precision Divide FDADD Double-Precision Add FDSUB Double-Precision Subtract FDMUL Double-Precision Multiply FDDIV Double-Precision Divide FSQRT Square Root FSSQRT Single-Precision Square Root FDSQRT Double-Precision Square Root FNOP No Operation FSAVE Save Internal State FRESTORE Restore Internal State FSGLDIV Single-Precision Divide (68882 compatible) FSGLMUL Single-Precision Multiply (68882 compatible) ------------------------------------------------------------------ Table 3-2. Support for Data Types and Data Formats ------------------------------------------------------------------ | Data Formats |---------------------------------------------------- Data Types | SGL | DBL | EXT | Dec | Byte | Word | Long ------------------------------------------------------------------ Norm * * * @ * * * Zero * * * @ * * * Infinity * * * @ NaN * * * @ Denorm # # @ @ Unnorm @ @ ------------------------------------------------------------------ Notes: @ = supported by FPSP * = supported by the MC68040 FPU # = supported by FPSP after being converted to extended precision by MC68040 Table 3-3. Operand Errors Handled by the MC68040 ------------------------------------------------------------------ Instruction | Conditions Causing Operand Error ------------------------------------------------------------------ FADD ( + inf )+( - inf ) or (- inf )+( + inf ) FSUB ( + inf )-( + inf ) or (- inf )-(- inf ) FMUL ( 0 ) x ( inf ) or ( inf ) x ( 0 ) FDIV 0 / 0 or inf / inf FMOVE.BWL Integer overflow, Source is NaN, or Source is inf FSQRT Source < 0, Source = - inf ------------------------------------------------------------------ Table 3-4. Operand Errors Generated by the FPSP ------------------------------------------------------------------ Instruction | Condition Causing Operand Error ------------------------------------------------------------------ FSADD ( + inf )+( - inf ) or ( - inf )+( + inf ) FDADD ( + inf )+( - inf ) or ( - inf )+( + inf ) FSSUB ( + inf )-( + inf ) or ( - inf )-( - inf ) FDSUB ( + inf )-( + inf ) or ( - inf )-( - inf ) FSMUL ( 0 ) x ( inf ) or ( inf ) x ( 0 ) FDMUL ( 0 ) x ( inf ) or ( inf ) x ( 0 ) FSDIV 0 / 0 or inf / inf FDDIV 0 / 0 or inf / inf FCOS Source is +/- inf FSIN Source is +/- inf FTAN Source is +/- inf FACOS Source is +/- inf, > +1, or < -1 FASIN Source is +/- inf, > +1, or < -1 FATANH Source is > +1, or < -1, Source = <20> inf FSINCOS Source is +/- inf FGETEXP Source is +/- inf FGETMAN Source is +/- inf FLOG10 Source is < 0, Source = - inf FLOG2 Source is +/- inf, > +1, or < -1 FLOGN Source is +/- inf, > +1, or < -1 FLOGNP1 Source is < -1, Source is = - inf FMOD FPx is +/- inf or Source is 0, Other Operand is not a NaN FMOVE to P Result Exponent > 999 (Decimal) or k-Factor > +17 FREM FPx is +/- inf or Source, Other Operand is not a NaN FSCALE Source is +/- inf, Other Operand is not a NaN ------------------------------------------------------------------ Table 3-5. DZ Exceptions Generated by the FPSWP ------------------------------------------------------------------ <0A> Instruction | Condition Causing DZ Exception ------------------------------------------------------------------ FATANH Source Operand = $ + -$1 FLOG10 Source Operand = 0 FLOG2 Source Operand = 0 FLOGN Source Operand = 0 FLOGNP1 Source Operand = -1 FSGLDIV Source Operand = 0 and FPn is not a NaN, Infinity, or 0 ------------------------------------------------------------------ Table 3-6. DZ Exceptions Generated by the MC68040 ------------------------------------------------------------------ Instruction | Condition Causing DZ Exception ------------------------------------------------------------------ FDIV Source Operand = 0 and FPn is not a NaN, Infinity, or 0 FSDIV Source Operand = 0 and FPn is not a NaN, Infinity, or 0 FDDIV Source Operand = 0 and FPn is not a NaN, Infinity, or 0 ------------------------------------------------------------------ Table 3-7. Arithmetic Instructions ------------------------------------------------------------------ Name | Description ------------------------------------------------------------------ FADD* Add FSUB* Subtract FSADD*+ Single-Precision Add FSSUB*+ Single-Precision Subtract FDADD*+ Double-Precision Add FDSUB*+ Double-Precision Subtract FMUL* Multiply FDIV* Divide FSMUL*+ Single-Precision Multiply FSDIV*+ Single-Precision Divide FDMUL*+ Double-Precision Multiply FDDIV*+ Double-Precision Divide FINT Integer Part FINTRZ Integer Part (Truncated) FABS* Absolute Value FNEG* Negate FGETEXP Get Exponent FGETMAN Get Mantissa FTST* Test Operand FCMP* Compare FREM IEEE Remainder FSCALE Scale Exponent FMOVE* Move FP data register FSMOVE* Single-Precision Move FDMOVE* Double-Precision Move FSQRT* Square Root FSSQRT* Single-Precision Square Root FTWOTOX 2 to the X Power FMOD Modulo Remainder FDSQRT* Double-Precision Square Root FDMOD Double-Precision Modulo Remainder FSMOD Single-Precision Modulo Remainder ------------------------------------------------------------------ Notes: * The FPSP provides these functions for all decimal data formats, single, double, and extended denormalized data types, and extended unnormalized data types. The MC68040 provides these functions for the remaining formats and types (See page 11 of Reference 2). + Additional functions which are not provided by the MC68881/MC68882. Table 3-8. Transcendental Instructions ------------------------------------------------------------------ Name | Description ------------------------------------------------------------------ FCOS Cosine FSIN Sine FACOS Arc Cosine FASIN Arc Sine FCOSH Hyperbolic Cosine FSINH Hyperbolic Sine FSINCOS Simultaneous Sine & Cosine FATAN Arc Tangent FTAN Tangent FATANH Hyperbolic Arc Tan FTANH Hyperbolic Tangent FLOG10 Log Base 10 FLOG2 Log Base 2 FLOGNP1 Log Base e of (x+1) FLOGN Log Base e FETOXM1 (e to the x Power) -1 FETOX e to the x Power FTWOTOX 2 to the x Power FTENTOX 10 to the x Power ------------------------------------------------------------------ Table 3-9. FPSP Provided Entry Points ------------------------------------------------------------------ Exception Type | Vector Table | FPSP entry | User entry | (offset) | point | point ------------------------------------------------------------------ F-line unimplemented vector 11 ($2C) fline real_fline float instruction ------------------------------------------------------------------ Branch or set on vector 48 ($20) bsun real_bsun unordered ------------------------------------------------------------------ Inexact vector 49 ($C4) inex real_inex ------------------------------------------------------------------ Divide-by-zero vector 50 ($C8) dz real_dz ------------------------------------------------------------------ Underflow vector 51 ($CC) unfl real_unfl ------------------------------------------------------------------ Operand error vector 52 ($D0) operr real_operr ------------------------------------------------------------------ Overflow vector 53 ($D4) ovfl real_ovfl ------------------------------------------------------------------ Signalling Not-A- vector 54 ($D8) snan real_snan Number ------------------------------------------------------------------ Unsupported data type vector 55 ($DC) unsupp ------------------------------------------------------------------ File: skeleton.sa |---------------------| | | File: x_unfl.sa | | |----------------------| VECTOR | | | | TABLE | | /->|fpsp_unfl: | |------------| /->|unfl: | | | . | | | | | jmp fpsp_unfl ----|-/ | . | | | | | | | . | vbr+$cc |addr of unfl|-/ | | | HANDLE NON-MASKABLE | | | |real_unfl: <--------|--\ | EXCEPTION CONDITION | | | | . | | | . | | | | . | | | . | | | | . | | | . | | | | USER TRAP HANDLER | | | | |------------| | . | | | if FPCR Exception | | . | | | Byte UNFL bit set,| | . | \-|-- jmp real_unfl | |rte . | | else rte | | | |----------------------| |---------------------| Figure 3-1 FPSP Entry Points SECTION 4 FPSP Library Version 4.1 When to use the FPSP Library Version. The FPSP Library Version is intended to provide better performance for trancendental instructions. It gets its performance by avoiding the overhead involved in F-line trap emulation, as used by the Unimplemented Instruction Handler. The FPSP Library Version is optional, and user code needs to be recompiled to make use of it. 4.2 Installation Notes The library version of the FPSP can be built by running 'make libFPSP.a' from either the Makefile (for asm syntax) or fpsp.mk (for as syntax). The 'make convert' step in Makefile will build both kernel and library .s files from the .sa sources. Change the SYS= and PREFIX= variables in Makefile BEFORE running 'make convert'. Three templates are supplied for building the library version: GEN, CI5 and R3V6. The GEN templates generate entry points for single, double and extended precision routines and provide the closest emulation of the kernel FPSP. The CI5 and R3V6 templates are faster, but discard most of the condition code and control register handling, and only provide the double precision entry points. The entry point names are contained in L_LIST. Change the first 3 entries of each line to suit your system. 4.3 Differences in the library version: 1.) Single and Double precision SNAN's will not generate an SNAN exception because they are converted to extended precision and doing so causes them to turn into non-signalling NAN's. Example: facos.d 7ff7_ffff_ffff_ffff snan 2.) An enabled Inexact exception may not be taken in all cases. Example: facos.x 000000000000000000000001 d inex2 fint.x 403d_0000_aaaa_aaaa_aaaa_ffff inex2 3.) The return value in fp0 is undefined when an enabled OPERR or DZ exception ocurrs. In the kernel FPSP, the destination register is unchanged. 4.)fscale does not return the right result when an underflow ocurrs. The problem is that the t_unfl code in the l_support.sa file cannot exactly mimic the kernel FPSP version because the incoming FPCR is not in the same place every time. 4.4 Changes in the library version of FPSP rel 2.3: A floating point exception occurs when a transcendentals called twice. example: main() { double d; d= 0.0; x = facosd(0.0); y = facosd(d); } This is fixed in release 2.2 of FPSP. A followup on the above bug was to restore the fpcr beforw it unlinks. This is fixed in release 2.3 of FPSP. 4.5 Performance Overall, the library version is twice as fast as the kernel code. APPENDIX A BUG TEMPLATE Use the template below when reporting bugs. Any fields designated with an asterick (*) can be left blank. When complete, please fax the report to the following phone number : (800) 248-8567 To assist you in filling out this form, a description of each field follows the template. Should you have any questions, please fax us at the above number. ---------------------------------------------------------------------------- Problem# (0-0000) Key Words Severity (1,2,3) Customer Description Long Description System Description Date Reported Reported By Phone *Resolved? *Date Resolved *Who fixed *Correction Description *Modules Affected Problem Release/Load *Test suite passed *sccs version control --------------------------------------------------------------------------- The following is a brief description of how to use the bug report template. --------------------------------------------------------------------------- Problem# (0-0000) You may include a number that you will use internally to track this bug. We will log it but assign our own # to track your bug repair. Please choose one person as the individual to send in all bug reports for your firm. This should help avoid confusion and ensure a smooth working relationship. Key Words Indicate the key terms associated with this bug report. For example: fpcr, denorm Severity (1,2,3,4,5) This indicates the severity of the bug. The following descriptions are taken from AT&T test document: 1: an error that causes the FPSP to crash and no further work can be done. An error that causes gross deviations of results. Non-waiverable compliance violations are also severity 1. 2: an error that represents a substantial deviation in the functionality of the FPSP or deviation from IEEE 754 standard. 3: an error that represents a deviation in the functionality. However, the customer is able to implement a workaround to this problem. 4: an error that represents a minor deviation or incorrect documentation. 5: a request for product enhancement. Customer Description This is a brief description of the problem. Long Description This is a more detailed description of the problem. This could contain a short code fragment, a suggested fix for the bug or reference a longer file with this type of information in it. System Description This is a brief description of your system. Date Reported MM/DD/YY Reported By Your name Phone Enter your telephone number including the area code. *Resolved? Enter "yes" or "no" only. *Date Resolved When the bug is fixed the date it was fixed will be entered by us in this field. *Who fixed Name of the person who fixed the bug. *Correction Description When the bug is fixed we will enter a description of the fix in this field. *Modules Affected When the bug is fixed we will enter the module name. Problem Release/Load Enter the release or load information in this field. This information should be on the label for the tape that was sent to you. *Test suite passed You do not need to fill out this field. This is the test suite file that we use to verify bugs and/or fixes. *sccs version control You do not need to fill out this field. This is the sccs version that contains the fix.