# $NetBSD: GENERIC,v 1.44 1997/06/10 21:54:21 pk Exp $
|
|
|
|
include "arch/sparc/conf/std.sparc"
|
|
|
|
# Options for variants of the Sun SPARC architecure.
|
|
# At least one is required.
|
|
options SUN4 # sun4/100, sun4/200, sun4/300
|
|
options SUN4C # sun4c - SS1, 1+, 2, ELC, SLC, IPC, IPX, etc.
|
|
options SUN4M # sun4m - SS10, SS20, Classic, etc.
|
|
|
|
#options MMU_3L # 3-level MMU on sun4/400; (incomplete)
|
|
|
|
# Standard system options
|
|
options KTRACE # system call tracing
|
|
options SYSVMSG # System V message queues
|
|
options SYSVSEM # System V semaphores
|
|
options SYSVSHM # System V shared memory
|
|
#options SHMMAXPGS=1024 # 1024 pages is the default
|
|
options LKM # loadable kernel modules
|
|
#options INSECURE # disable kernel security level
|
|
#options UCONSOLE # allow anyone to steal the virtual console
|
|
|
|
# Debugging options
|
|
#options DDB # kernel dynamic debugger
|
|
#options DEBUG # kernel debugging code
|
|
#options DIAGNOSTIC # extra kernel sanity checking
|
|
#options KGDB # support for kernel gdb
|
|
#options KGDBDEV=0xc01 # kgdb device number (dev_t)
|
|
#options KGDBRATE=38400 # baud rate
|
|
|
|
# Compatibility options
|
|
options COMPAT_43 # 4.3BSD system interfaces
|
|
options COMPAT_10 # NetBSD 1.0 binary compatibility
|
|
options COMPAT_11 # NetBSD 1.1 binary compatibility
|
|
options COMPAT_12 # NetBSD 1.2 binary compatibility
|
|
options COMPAT_SUNOS # SunOS 4.x binary compatibility
|
|
options COMPAT_SVR4 # SunOS 5.x binary compatibility
|
|
options EXEC_ELF32 # Exec module for SunOS 5.x binaries.
|
|
|
|
# Filesystem options
|
|
file-system FFS # Berkeley Fast Filesystem
|
|
file-system NFS # Sun NFS-compatible filesystem client
|
|
file-system KERNFS # kernel data-structure filesystem
|
|
file-system NULLFS # NULL layered filesystem
|
|
file-system MFS # memory-based filesystem
|
|
file-system FDESC # user file descriptor filesystem
|
|
file-system UMAPFS # uid/gid remapping filesystem
|
|
file-system LFS # Log-based filesystem (still experimental)
|
|
file-system PORTAL # portal filesystem (still experimental)
|
|
file-system PROCFS # /proc
|
|
file-system CD9660 # ISO 9660 + Rock Ridge file system
|
|
file-system UNION # union file system
|
|
file-system MSDOSFS # MS-DOS FAT filesystem(s).
|
|
|
|
options NFSSERVER # Sun NFS-compatible filesystem server
|
|
options QUOTA # FFS quotas
|
|
options FIFO # POSIX fifo support (in all filesystems)
|
|
|
|
# Networking options
|
|
options INET # IP stack
|
|
options TCP_COMPAT_42 # compatibility with 4.2BSD TCP/IP
|
|
#options GATEWAY # IP packet forwarding
|
|
#options ISO,TPIP # OSI networking
|
|
#options EON # OSI tunneling over IP
|
|
#options CCITT,LLC,HDLC # X.25
|
|
#options PFIL_HOOKS # pfil(9) packet filter hooks.
|
|
|
|
# Options for SPARCstation hardware
|
|
options RASTERCONSOLE # fast rasterop console
|
|
|
|
# Generic swap; second partition of root disk or network.
|
|
config netbsd root on ? type ?
|
|
|
|
# Main bus and CPU .. all systems.
|
|
mainbus0 at root
|
|
cpu0 at mainbus0
|
|
|
|
# Bus types found on SPARC systems.
|
|
sbus0 at mainbus0 # sun4c
|
|
obio0 at mainbus0 # sun4 and sun4m
|
|
vmes0 at mainbus0 # sun4
|
|
vmel0 at mainbus0 # sun4
|
|
iommu0 at mainbus0 # sun4m
|
|
sbus0 at iommu0 # sun4m
|
|
|
|
audio0 at mainbus0 # sun4c
|
|
audio0 at obio0 # sun4m
|
|
audio0 at sbus0 slot ? offset ? # sun4m
|
|
|
|
auxreg0 at mainbus0 # sun4c
|
|
auxreg0 at obio0 # sun4m
|
|
|
|
# Power status and control register found on Sun4m systems
|
|
power0 at obio0
|
|
|
|
# Mostek clock found on 4/300, sun4c, and sun4m systems.
|
|
# The Mostek clock NVRAM is the "eeprom" on sun4/300 systems.
|
|
clock0 at mainbus0 # sun4c
|
|
clock0 at obio0 # sun4m
|
|
clock0 at obio0 addr 0xf2000000 # sun4/300
|
|
|
|
# Intersil clock found on 4/100 and 4/200 systems.
|
|
oclock0 at obio0 addr 0xf3000000 # sun4/200
|
|
oclock0 at obio0 addr 0x03000000 # sun4/100
|
|
|
|
# Memory error registers.
|
|
memreg0 at mainbus0 # sun4c
|
|
memreg0 at obio0 # sun4m
|
|
memreg0 at obio0 addr 0xf4000000 # sun4/200 and sun4/300
|
|
memreg0 at obio0 addr 0x04000000 # sun4/100
|
|
|
|
# Timer chip found on 4/300, sun4c, and sun4m systems.
|
|
timer0 at mainbus0 # sun4c
|
|
timer0 at obio0 # sun4m
|
|
timer0 at obio0 addr 0xef000000 # sun4/300
|
|
|
|
# EEPROM found on 4/100 and 4/200 systems. Note that the 4/300
|
|
# doesn't use this driver; the `EEPROM' is in the NVRAM on the
|
|
# Mostek clock chip on 4/300 systems.
|
|
eeprom0 at obio0 addr 0xf2000000 # sun4/200
|
|
eeprom0 at obio0 addr 0x02000000 # sun4/100
|
|
|
|
# Zilog 8530 serial chips. Each has two-channels.
|
|
# zs0 is ttya and ttyb. zs1 is the keyboard and mouse.
|
|
zs0 at mainbus0 # sun4c
|
|
zs0 at obio0 # sun4m
|
|
zs0 at obio0 addr 0xf1000000 level 12 flags 0x103 # sun4/200 and sun4/300
|
|
zs0 at obio0 addr 0x01000000 level 12 flags 0x103 # sun4/100
|
|
zs1 at mainbus0 # sun4c
|
|
zs1 at obio0 # sun4m
|
|
zs1 at obio0 addr 0xf0000000 level 12 flags 0x103 # sun4/200 and sun4/300
|
|
zs1 at obio0 addr 0x00000000 level 12 flags 0x103 # sun4/100
|
|
zs2 at obio0 addr 0xe0000000 level 12 flags 0x103 # sun4/300
|
|
|
|
#
|
|
# Note the flags on the esp entries below, that work around
|
|
# deficiencies in the current driver:
|
|
# bits 0-7: disable disconnect/reselect for the corresponding target
|
|
# bits 8-15: disable synch negotiation for target [bit-8]
|
|
# Note: targets 4-7 have disconnect/reselect enabled on the premise
|
|
# that tape devices normally have one of these targets. Tape
|
|
# devices should be allowed to disconnect for the SCSI bus
|
|
# to operate acceptably.
|
|
#
|
|
|
|
# sun4/300 SCSI - an NCR53c94 or equivalent behind
|
|
# an LSI Logic DMA controller
|
|
dma0 at obio0 addr 0xfa001000 level 4 # sun4/300
|
|
esp0 at obio0 addr 0xfa000000 level 4 flags 0xff0f #
|
|
|
|
# sun4c or sun4m SCSI - an NCR53c94 or equivalent behind
|
|
# specialized DMA glue
|
|
dma0 at sbus0 slot ? offset ? # on-board SCSI
|
|
esp0 at sbus0 slot ? offset ? flags 0xff0f # sun4c
|
|
esp0 at dma0 flags 0xff0f # sun4m
|
|
|
|
# FSBE/S SCSI - an NCR53c94 or equivalent behind
|
|
dma* at sbus? slot ? offset ? # SBus SCSI
|
|
esp* at sbus? slot ? offset ? flags 0xff0f # two flavours
|
|
esp* at dma? flags 0xff0f # depending on model
|
|
|
|
# Qlogic ISP SBus SCSI Card
|
|
isp* at sbus? slot ? offset ?
|
|
|
|
# sun4m Ethernet - an AMD 7990 LANCE behind
|
|
# specialized DMA glue
|
|
ledma0 at sbus0 slot ? offset ? # sun4m on-board
|
|
le0 at ledma0 #
|
|
|
|
# Additional SBus LANCE devices - glued on by lebuffer
|
|
lebuffer0 at sbus0 slot ? offset ? # sun4m SBus
|
|
lebuffer* at sbus? slot ? offset ? # sun4m SBus
|
|
le0 at lebuffer0 #
|
|
le* at lebuffer? #
|
|
|
|
# sun4/300 and sun4c Ethernet - an AMD 7990 LANCE
|
|
le0 at sbus0 slot ? offset ? # sun4c on-board
|
|
le* at sbus? slot ? offset ?
|
|
|
|
le0 at obio0 addr 0xf9000000 level 6 # sun4/300
|
|
|
|
# sun4/100 and sun4/200 Ethernet - an Intel 82586 on-board
|
|
# or on a Multibus/VME card.
|
|
ie0 at obio0 addr 0xf6000000 level 6 # sun4/200 on-board
|
|
ie0 at obio0 addr 0x06000000 level 6 # sun4/100 on-board
|
|
|
|
ie1 at vmes0 addr 0xffe88000 level 5 vect 0x75
|
|
ie2 at vmel0 addr 0xff31ff02 level 5 vect 0x76
|
|
ie3 at vmel0 addr 0xff35ff02 level 5 vect 0x77
|
|
ie4 at vmel0 addr 0xff2dff02 level 5 vect 0x7c
|
|
|
|
# Xylogics 753 or 7053 VME SMD disk controllers and disks, found
|
|
# on sun4 systems.
|
|
xdc0 at vmel0 addr 0xffffee80 level 3 vect 0x44
|
|
xdc1 at vmel0 addr 0xffffee90 level 3 vect 0x45
|
|
xdc2 at vmel0 addr 0xffffeea0 level 3 vect 0x46
|
|
xdc3 at vmel0 addr 0xffffeeb0 level 3 vect 0x47
|
|
xd* at xdc? drive ?
|
|
|
|
# Xylogics 451 or 451 VME SMD disk controllers and disks, found
|
|
# on sun4 systems.
|
|
xyc0 at vmes0 addr 0xffffee40 level 3 vect 0x48
|
|
xyc1 at vmes0 addr 0xffffee48 level 3 vect 0x49
|
|
xy* at xyc? drive ?
|
|
|
|
# NCR5380-based "Sun SCSI 3" VME SCSI controller.
|
|
# This driver has several flags which may be enabled by OR'ing
|
|
# the values and using the "flags" directive.
|
|
# Valid flags are:
|
|
#
|
|
# 0x01 Use DMA (may be polled)
|
|
# 0x02 Use DMA completion interrupts
|
|
# 0x04 Allow disconnect/reselect
|
|
#
|
|
# E.g. the following would enable DMA, interrupts, and reselect:
|
|
# si0 at vmes0 addr 0xff200000 level 3 vect 0x40 flags 0x07
|
|
#
|
|
# By default, DMA is enabled in the driver.
|
|
si0 at vmes0 addr 0xff200000 level 3 vect 0x40
|
|
|
|
# NCR5380-based "SCSI Weird" on-board SCSI interface found
|
|
# on sun4/100 systems. The flags are the same as the "si"
|
|
# controller. Note, while DMA is enabled by default, only
|
|
# polled DMA works at this time, and reselects do not work
|
|
# on this particular controller.
|
|
sw0 at obio0 addr 0x0a000000 level 3
|
|
|
|
# Sun "bwtwo" black and white framebuffer, found on sun4, sun4c, and sun4m
|
|
# systems. If your sun4 system has a cgfour installed in the P4 slot,
|
|
# the P4 entries for "bwtwo" will attach to the overlay plane of the
|
|
# "cgfour".
|
|
bwtwo0 at sbus0 slot ? offset ? # sun4c on-board
|
|
bwtwo* at sbus? slot ? offset ? # sun4c and sun4m
|
|
bwtwo0 at obio0 addr 0xfd000000 level 4 # sun4/200
|
|
bwtwo0 at obio0 addr 0xfb300000 level 4 # sun4/300 in P4 slot
|
|
bwtwo0 at obio0 addr 0x0b300000 level 4 # sun4/100 in P4 slot
|
|
|
|
# Sun "cgtwo" VME color framebuffer
|
|
cgtwo0 at vmes0 addr 0xff400000 level 4 vect 0xa8
|
|
|
|
# Sun "cgthree" Sbus color framebuffer
|
|
cgthree0 at sbus? slot ? offset ?
|
|
cgthree* at sbus? slot ? offset ?
|
|
#cgthree0 at obio? slot ? offset ? # sun4m
|
|
#cgthree* at obio? slot ? offset ? # sun4m
|
|
|
|
# Sun "cgfour" color framebuffer with overlay plane. See above comment
|
|
# regarding overlay plane.
|
|
cgfour0 at obio0 addr 0xfb300000 level 4 # sun4/300 P4
|
|
cgfour0 at obio0 addr 0x0b300000 level 4 # sun4/100 P4
|
|
|
|
# Sun "cgsix" accelerated color framebuffer.
|
|
cgsix0 at sbus? slot ? offset ?
|
|
cgsix* at sbus? slot ? offset ?
|
|
cgsix0 at obio0 addr 0xfb000000 level 4 # sun4/300 P4
|
|
cgsix0 at obio0 addr 0x0b000000 level 4 # sun4/100 P4
|
|
|
|
# Sun "cgeight" 24-bit framebuffer
|
|
cgeight0 at obio0 addr 0xfb300000 level 4 # sun4/300 P4
|
|
cgeight0 at obio0 addr 0x0b300000 level 4 # sun4/100 P4
|
|
|
|
# Sun "tcx" accelerated color framebuffer.
|
|
tcx0 at sbus? slot ? offset ?
|
|
tcx* at sbus? slot ? offset ?
|
|
|
|
# Sun "cgfourteen" accelerated 24-bit framebuffer.
|
|
cgfourteen0 at obio0 # sun4m
|
|
|
|
# SCSI bus layer. SCSI devices attach to the SCSI bus, which attaches
|
|
# to the underlying hardware controller.
|
|
scsibus* at esp?
|
|
scsibus* at isp?
|
|
scsibus* at si?
|
|
scsibus* at sw?
|
|
|
|
# These entries find devices on all SCSI busses and assign
|
|
# unit numbers dynamically.
|
|
sd* at scsibus? target ? lun ? # SCSI disks
|
|
st* at scsibus? target ? lun ? # SCSI tapes
|
|
cd* at scsibus? target ? lun ? # SCSI CD-ROMs
|
|
ch* at scsibus? target ? lun ? # SCSI changer devices
|
|
|
|
# Floppy controller and drive found on SPARCstations.
|
|
fdc0 at mainbus0 # sun4c controller
|
|
fdc0 at obio0 # sun4m controller
|
|
fd* at fdc0 # the drive itself
|
|
|
|
pseudo-device loop # loopback interface; required
|
|
pseudo-device pty 32 # pseudo-ttys (for network, etc.)
|
|
pseudo-device sl 2 # SLIP interfaces
|
|
pseudo-device kbd # Sun keyboard
|
|
pseudo-device ppp 2 # PPP interfaces
|
|
pseudo-device tun 4 # Network "tunnel" device
|
|
pseudo-device bpfilter 16 # Berkeley Packet Filter
|
|
pseudo-device vnd 4 # disk-like interface to files
|
|
pseudo-device ccd 4 # concatenated and striped disks
|
|
#pseudo-device strip 1 # radio clock
|
|
#pseudo-device ipfilter # ip filter
|