restart if we get multiple status interrupts before the softintr()
routine gets a chance to run. The fix is to determine and accumulate
status line changes at the H/W interrupt level, and then check and zero
the accumulated changes when the softint() finally runs. Many thanks
to Bill Studenmund <wrstuden@loki.stanford.edu> for finding and fixing.