NetBSD/sys/arch/amiga/dev/siop2_script.ss
mhitch 91d0eb55ed More 53c770 stuff: update 53c720/770 register defines and use them in
siop2.c.  Add wide negotiation and Ultra support.  Modify siop.c to match
the siop2.c sync negotiation changes.  The CyberStorm MKIII driver now
supports 15 targets.  Remove some old table-driven sync rate stuff from
the original Zeus driver.
1999-03-26 22:50:22 +00:00

220 lines
6.3 KiB
Scheme

; $NetBSD: siop2_script.ss,v 1.3 1999/03/26 22:50:23 mhitch Exp $
;
; Copyright (c) 1998 Michael L. Hitch
; All rights reserved.
;
; Redistribution and use in source and binary forms, with or without
; modification, are permitted provided that the following conditions
; are met:
; 1. Redistributions of source code must retain the above copyright
; notice, this list of conditions and the following disclaimer.
; 2. Redistributions in binary form must reproduce the above copyright
; notice, this list of conditions and the following disclaimer in the
; documentation and/or other materials provided with the distribution.
; 3. All advertising materials mentioning features or use of this software
; must display the following acknowledgement:
; This product includes software developed by Michael L. Hitch.
; 4. The name of the author may not be used to endorse or promote products
; derived from this software without specific prior written permission
;
; THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
; IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
; OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
; IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
; INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
; NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
; DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
; THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
; (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
; THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
;
; NCR 53c770 script
;
ARCH 720
;
ABSOLUTE ds_Device = 0
ABSOLUTE ds_MsgOut = ds_Device + 4
ABSOLUTE ds_Cmd = ds_MsgOut + 8
ABSOLUTE ds_Status = ds_Cmd + 8
ABSOLUTE ds_Msg = ds_Status + 8
ABSOLUTE ds_MsgIn = ds_Msg + 8
ABSOLUTE ds_ExtMsg = ds_MsgIn + 8
ABSOLUTE ds_NegMsg = ds_ExtMsg + 8
ABSOLUTE ds_Data1 = ds_NegMsg + 8
ABSOLUTE ds_Data2 = ds_Data1 + 8
ABSOLUTE ds_Data3 = ds_Data2 + 8
ABSOLUTE ds_Data4 = ds_Data3 + 8
ABSOLUTE ds_Data5 = ds_Data4 + 8
ABSOLUTE ds_Data6 = ds_Data5 + 8
ABSOLUTE ds_Data7 = ds_Data6 + 8
ABSOLUTE ds_Data8 = ds_Data7 + 8
ABSOLUTE ds_Data9 = ds_Data8 + 8
ABSOLUTE ok = 0xff00
ABSOLUTE err1 = 0xff01
ABSOLUTE err2 = 0xff02
ABSOLUTE err3 = 0xff03
ABSOLUTE err4 = 0xff04
ABSOLUTE err5 = 0xff05
ABSOLUTE err6 = 0xff06
ABSOLUTE err7 = 0xff07
ABSOLUTE err8 = 0xff08
ABSOLUTE err9 = 0xff09
ABSOLUTE err10 = 0xff0a
ABSOLUTE err11 = 0xff0b
ENTRY scripts
ENTRY switch
ENTRY wait_reselect
ENTRY dataout
ENTRY datain
ENTRY clear_ack
PROC siopng_scripts:
scripts:
SELECT ATN FROM ds_Device, REL(reselect)
;
switch:
JUMP REL(msgin), WHEN MSG_IN
JUMP REL(msgout), IF MSG_OUT
JUMP REL(command_phase), IF CMD
JUMP REL(dataout), IF DATA_OUT
JUMP REL(datain), IF DATA_IN
JUMP REL(end), IF STATUS
INT err5 ; Unrecognized phase
msgin:
MOVE FROM ds_MsgIn, WHEN MSG_IN
JUMP REL(ext_msg), IF 0x01 ; extended message
JUMP REL(disc), IF 0x04 ; disconnect message
JUMP REL(msg_sdp), IF 0x02 ; save data pointers
JUMP REL(msg_rej), IF 0x07 ; message reject
JUMP REL(msg_rdp), IF 0x03 ; restore data pointers
INT err6 ; unrecognized message
msg_rej:
; Do we need to interrupt host here to let it handle the reject?
msg_rdp:
clear_ack:
CLEAR ACK
CLEAR ATN
JUMP REL(switch)
ext_msg:
CLEAR ACK
MOVE FROM ds_ExtMsg, WHEN MSG_IN
JUMP REL(neg_msg), IF 0x03 ; extended message might be SDTR
JUMP REL(neg_msg), IF 0x02 ; extended message might be WDTR
int err7 ; extended message not SDTR
neg_msg:
CLEAR ACK
MOVE FROM ds_NegMsg, WHEN MSG_IN
int err11 ; Let host handle the message
; If we continue from the interrupt, the host has set up a response
; message to be sent. Set ATN, clear ACK, and continue.
SET ATN
CLEAR ACK
JUMP REL(switch)
disc:
MOVE SCNTL2 & 0x7f TO SCNTL2
CLEAR ACK
WAIT DISCONNECT
int err2 ; signal disconnect w/o save DP
msg_sdp:
CLEAR ACK ; acknowledge message
JUMP REL(switch), WHEN NOT MSG_IN
MOVE FROM ds_ExtMsg, WHEN MSG_IN
INT err8, IF NOT 0x04 ; interrupt if not disconnect
MOVE SCNTL2 & 0x7f TO SCNTL2
CLEAR ACK
WAIT DISCONNECT
INT err1 ; signal disconnect
reselect:
wait_reselect:
WAIT RESELECT REL(select_adr)
MOVE SSID & 0x8f to SFBR ; Save reselect ID
MOVE SFBR to SCRATCHA0
INT err9, WHEN NOT MSG_IN ; didn't get IDENTIFY
MOVE FROM ds_Msg, WHEN MSG_IN
INT err3 ; let host know about reconnect
CLEAR ACK ; acknowlege the message
JUMP REL(switch)
select_adr:
MOVE SCNTL1 & 0x10 to SFBR ; get connected status
INT err4, IF 0x00 ; tell host if not connected
MOVE CTEST2 & 0x40 to SFBR ; clear Sig_P
JUMP REL(wait_reselect) ; and try reselect again
msgout:
MOVE FROM ds_MsgOut, WHEN MSG_OUT
JUMP REL(switch)
command_phase:
CLEAR ATN
MOVE FROM ds_Cmd, WHEN CMD
JUMP REL(switch)
dataout:
MOVE FROM ds_Data1, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data2, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data3, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data4, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data5, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data6, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data7, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data8, WHEN DATA_OUT
CALL REL(switch), WHEN NOT DATA_OUT
MOVE FROM ds_Data9, WHEN DATA_OUT
CALL REL(switch)
datain:
MOVE FROM ds_Data1, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data2, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data3, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data4, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data5, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data6, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data7, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data8, WHEN DATA_IN
CALL REL(switch), WHEN NOT DATA_IN
MOVE FROM ds_Data9, WHEN DATA_IN
CALL REL(switch)
end:
MOVE FROM ds_Status, WHEN STATUS
int err10, WHEN NOT MSG_IN ; status not followed by msg
MOVE FROM ds_Msg, WHEN MSG_IN
MOVE SCNTL2 & 0x7f TO SCNTL2
CLEAR ACK
WAIT DISCONNECT
INT ok ; signal completion
JUMP REL(wait_reselect)