Commit Graph

12 Commits

Author SHA1 Message Date
joerg
bec77c5f43 Use __dead 2011-08-31 13:32:36 +00:00
pgoyette
eaed4c6e56 Instead of relying on the want-percent attribute, use the sensor
type to restrict value-based limits from Battery-capacity sensors.
2011-06-08 16:11:25 +00:00
pgoyette
87b1c2cb4e Apply proper conversion (which is _no_ conversion) when setting limit
values for sensors of type ENVSYS_INTEGER.
2010-10-05 05:03:49 +00:00
pgoyette
74999bdda4 Update userland envstat(8) to handle new {high,maximum}-capacity limits. 2010-02-15 22:37:14 +00:00
pgoyette
6d65ba8398 1. provide for warning-min and warning-max alarm levels in addition to
critical-min and critical-max; also, a battery warning-capacity is
   added in addition to a critical-capacity.

2. usr.sbin/envstat is modified to introduce a -W command line switch to
   display the warning-* values instead of the critical-* values, and
   envstat(8) and envsys.conf(5) man pages are updated appropriately.

3. Treat user-defined limits as a single continuum and generate a single
   event regardless of how many boundaries a change in sensor value
   crosses;  ditto for driver-defined limits.

Fixes my PR/39021
Fixes my PR/39022

OK'd by christos@ bouyer@ cube@
2008-08-22 11:27:50 +00:00
xtraeme
16f978c748 Fix a bug in the 'refresh-timeout' device property that was giving
the same value to all devices even if the configuration file was
changed.
2008-02-02 01:44:04 +00:00
xtraeme
27ddba0559 Implement the 'refresh-timeout' property in device blocks for the
configuration files. This sets the timeout value that will be used
to check for critical limits.

The value can be viewed by the 'envstat -D' command.
2007-11-16 08:01:37 +00:00
xtraeme
2e75cc0f7b - Do not allow a 'critical-{max,min}' property in battery
sensors (those that contain the 'want-percentage' object on its
  dictionary), the 'critical-capacity' prop must be used instead.

- When setting a 'critical-{max,min}' property check if the value is
  higher than the 'max-value' or lower than the 'min-value' on its
  dictionary, raise an error if it's true.
2007-10-09 08:00:46 +00:00
xtraeme
eed1cc9bc8 Fix a typo that prevented a 'critical-capacity' property to
be added.
2007-10-09 02:29:37 +00:00
xtraeme
12b91c398d If a critical-capacity property is found, make sure that the
'monitoring-supported' object is true.
2007-10-07 16:22:37 +00:00
xtraeme
2839febced Use two global dictionaries rather than only one:
- use one for temporary sensor dictionaries.
- use one as the dictionary that will be returned to send_dictionary().

This fixes multiple settings in multiple devices.
2007-10-07 13:48:03 +00:00
xtraeme
f2803256d9 New configuration file format for the envsys framework:
foo0 {
	#
	# CPU Temperature
	#
	sensor0 {
		critical-max = 70C;
		critical-min = 20C;
	}
	...
}
...

Removed the -m flag that was previously used to set properties for
sensors. Now the -c flag will process all properties specified in
the file (accepted as argument).

To remove all properties that were set, the new -S flag can be used.
This will restore default values for all devices.
2007-10-07 04:16:47 +00:00