- en_mfix shouldn't touch M_EXT mbufs. change to avoid this [at
the expense of allocating a new cluster mbuf to copy to].
XXX: en_mfix is getting called more often than I hoped it would
(seems to happen when TCP retransmits... we get all sorts of odd
sized, odd lengthed data mbufs, yuck). i may revise the xmit
DMA code to use non-word sized dma.
- don't try and add a PDU trailer (or TBD for that matter) to an M_EXT
mbuf. when M_EXT is set, the data area of the mbuf can be shared
with other mbufs (see m_copym()), and writing to one M_EXT mbuf may
invalidate another M_EXT mbuf (saw this with PDU trailers).
- be sure to validate the length value from the PDU trailer so that it
doesn't throw us out of sync with the chip (fixes yet another source
of the dread "en_service: id mismatch" panic).
- on recv, don't bother allocating an mbuf if mlen is zero since we are
only going to toss the data anyway.
to ignore inbound data sizes less than the threshold. otherwise,
when connected to a video aal0 input the driver gives us a massive
stream of 56 byte mbufs each with one aal0 cell in it and the
system just can't keep up with it, especially if the socket buffer
size is large [it hangs until you turn off the video source].
fixes: when turning off a vc, try and check the freshest copy of the mode
when seeing if we need to enter the "drain" state. also, don't
panic if we get unexpected rx interrupt on a VCI (instead make sure
the VC is off, print a warning, and move on!).
- change rxso into a void handle ... no need to know details at this low
level.
fix:
- forgot to init "vci" during ENOTHER_DRAIN case of RX DMA interrupt
[could cause a vm_fault on native mode connection close depending
on needing to drain out the VC and also the random value of vci]
- more stat counters (rxmbufout -- mbufs, ttrash -- trashed RBD)
- add swsl_size to keep track of size of software slist
- revise when we call en_service
- fix handling of circular lists (was getting full vs empty confused in
extreem cases...)
- native mode atm: remove sbappend code: can't do it here since
socket buffer is protected only by splsoftnet and that doesn't
mask enintr off. forces us to switch to a two level interrupt
scheme. revise call to atm_input to reflect that.
[1] rxslot "cur" pointer wasn't updated if we copied all data and
didn't have any fill. this could cause a service id mismatch
panic under load.
[2] recv of aal0 forgot to include the cell header in the data length
calc [add cell header length to midwayreg.h]
[3] fix control info "chop" for raw mode and aal0
[4] handle rxsb better for native atm connections
(XXX: still working on this ... not complete and needs revision)