bit from the extended setup inquiry and key off it to:
- Force synchronous negotiation on targs > 7.
- Read additional information returned by wide cards on inquire setup.
- Read sync period on targs > 7.
- Display sync period/offset on targs > 7.
- Set scsi_link.max_target to 15.
cvs: ----------------------------------------------------------------------
ISA-compatible port space of PCI buslogic cards.
* Add call to bha_pci.c to disable the ISA-compatible ports of a PCI
device. The ISA-compatible ports are enabled by default, which
causes the card to be autoconfigured a second time as an ISA device,
which appears to deadlock the card.
* Change bha_cmd() to return the number of bytes it actually received
in response to a command, or -1 on error.
* Use heuristics (checking for bha-only registers, and checking the size
of the response to BHA_INQURE_EXTENDED) to bha_find, to make sure the
bha driver never matches an aha (Adaptec 1542 or compatible) device.
A single kernel should now boot on either Adaptec or BusLogic controllers,
provided we always probe for BusLogic devices before Adaptec devices,
but this has not yet been verified.