Correct a component label problem where a RAID 1 set with a

failed component would not configure properly in certain situations.
This commit is contained in:
oster 1999-03-18 03:02:38 +00:00
parent ff4754d6e5
commit efe288e520
1 changed files with 15 additions and 2 deletions

View File

@ -1,4 +1,4 @@
/* $NetBSD: rf_disks.c,v 1.7 1999/03/02 03:18:49 oster Exp $ */
/* $NetBSD: rf_disks.c,v 1.8 1999/03/18 03:02:38 oster Exp $ */
/*-
* Copyright (c) 1999 The NetBSD Foundation, Inc.
* All rights reserved.
@ -652,7 +652,20 @@ rf_CheckLabels( raidPtr, cfgPtr )
/* Locate the maverick component */
if (mod_count[1] > mod_count[0]) {
mod_number = mod_values[1];
}
} else if (mod_count[1] < mod_count[0]) {
mod_number = mod_values[0];
} else {
/* counts of different modification values
are the same. Assume greater value is
the correct one, all other things
considered */
if (mod_values[0] > mod_values[1]) {
mod_number = mod_values[0];
} else {
mod_number = mod_values[1];
}
}
for (r = 0; r < raidPtr->numRow && !too_fatal ; r++) {
for (c = 0; c < raidPtr->numCol; c++) {
ci_label = &raidPtr->raid_cinfo[r][c].ci_label;