Some miscellaneous fixes:
* Apparently there is only a single location for the scripts. Thus, remove the references to "/etc/powerd/scripts/apm" and "/etc/powerd/scripts/acpi". * Correct confusion: instead of "the device with which the device is associated", write "the device with which the event is associated". Correct also an example related to this. * Improve wording, grammar, and markup in few places.
This commit is contained in:
parent
816eaf9482
commit
df40d4f10f
@ -1,4 +1,4 @@
|
||||
.\" $NetBSD: powerd.8,v 1.20 2010/01/26 14:28:23 jruoho Exp $
|
||||
.\" $NetBSD: powerd.8,v 1.21 2010/01/26 20:37:13 jruoho Exp $
|
||||
.\"
|
||||
.\" Copyright (c) 2003 Wasabi Systems, Inc.
|
||||
.\" All rights reserved.
|
||||
@ -63,27 +63,13 @@ Verbose messages will be sent to stderr and
|
||||
will stay in the foreground of the controlling terminal.
|
||||
.El
|
||||
.Sh CONFIGURATION SCRIPTS
|
||||
All of
|
||||
All configuration of
|
||||
.Nm
|
||||
configuration is encapsulated into scripts that are run when power
|
||||
management events occur.
|
||||
.Nm
|
||||
will look for these scripts in two locations.
|
||||
The first location is
|
||||
.Pa /etc/powerd/scripts/\*[Lt]power_type\*[Gt] ,
|
||||
where
|
||||
.Aq Pa power_type
|
||||
is defined by the power management mechanism supported by the system,
|
||||
e.g.,
|
||||
.Dq apm
|
||||
or
|
||||
.Dq acpi .
|
||||
If the script is not found in the first location,
|
||||
.Nm
|
||||
looks in
|
||||
is encapsulated into scripts that are run when power management events occur.
|
||||
The daemon will look for the scripts from the directory
|
||||
.Pa /etc/powerd/scripts .
|
||||
.Pp
|
||||
Configuration scripts are run synchronously, i.e.,
|
||||
Configuration scripts are run synchronously;
|
||||
.Nm
|
||||
will start the script and wait for its completion before it handles
|
||||
the next event.
|
||||
@ -95,7 +81,7 @@ These classes are described in the following sections.
|
||||
Power switch scripts are called when a state change event occurs on
|
||||
a power switch device.
|
||||
Power switch scripts are called with two arguments: the device with which
|
||||
the device is associated, and the event type.
|
||||
the event is associated, and the event type.
|
||||
.Pp
|
||||
The following power switch script names are defined:
|
||||
.Bl -tag -width "hotkey_button"
|
||||
@ -117,9 +103,11 @@ This script is called when an event occurs on a hotkey button device.
|
||||
The following events are defined for power switch devices:
|
||||
.Bl -tag -width "hotkey_button"
|
||||
.It Em pressed
|
||||
The button was pressed, the lid closed, or the AC adapter connected.
|
||||
The button was pressed, the lid was closed,
|
||||
or the AC adapter was connected.
|
||||
.It Em released
|
||||
The button was released, the lid opened, or the AC adapter disconnected.
|
||||
The button was released, the lid was opened,
|
||||
or the AC adapter was disconnected.
|
||||
Note that power and sleep button devices usually do not
|
||||
post this type of event.
|
||||
.El
|
||||
@ -127,13 +115,13 @@ post this type of event.
|
||||
The following is an example of how a power button script might be invoked
|
||||
when a power button is pressed by the operator:
|
||||
.Bd -literal -offset indent
|
||||
/etc/powerd/scripts/power_button acpi0 pressed
|
||||
/etc/powerd/scripts/power_button acpibut0 pressed
|
||||
.Ed
|
||||
.Ss ENVSYS SCRIPTS
|
||||
.Xr envsys 4
|
||||
scripts are called when a condition was triggered in a sensor.
|
||||
These scripts are called with three arguments: the
|
||||
device associated, the event type and sensor's name.
|
||||
device associated, the event type, and the sensor's name.
|
||||
The
|
||||
.Sy sensor_drive
|
||||
and the
|
||||
@ -161,15 +149,8 @@ This script is called when an event occurs on a temperature sensor.
|
||||
This script is called when an event occurs on a voltage sensor.
|
||||
.El
|
||||
.Pp
|
||||
The following event is defined for all scripts but is only sent if
|
||||
a critical/warning or any other event was previously sent:
|
||||
.Bl -tag -width "sensor_temperature"
|
||||
.It normal
|
||||
A normal state/capacity/condition was triggered.
|
||||
.El
|
||||
.Pp
|
||||
The following events are defined for fan, indicator, power,
|
||||
resistance, temperature and voltage sensors:
|
||||
resistance, temperature, and voltage sensors:
|
||||
.Bl -tag -width "sensor_temperature"
|
||||
.It Em critical
|
||||
A critical condition was triggered.
|
||||
@ -183,23 +164,28 @@ A warning under condition was triggered.
|
||||
A warning over condition was triggered.
|
||||
.El
|
||||
.Pp
|
||||
The following event is defined for all scripts, but it is only sent if
|
||||
any of the previous events has been previously sent:
|
||||
.Bl -tag -width "sensor_temperature"
|
||||
.It Em normal
|
||||
A normal state/capacity/condition was triggered.
|
||||
.El
|
||||
.Pp
|
||||
The following events are defined only for battery sensors:
|
||||
.Bl -tag -width "sensor_temperature"
|
||||
.It Em user-capacity
|
||||
Capacity dropped below the limit set by the user.
|
||||
.It Em low-power
|
||||
System is running in low power, that means that there is not
|
||||
any AC Adapter connected and all batteries are in critical or
|
||||
low capacity.
|
||||
When this event is received there's no much time so you should only
|
||||
suspend or shutdown the system.
|
||||
System is running in low power.
|
||||
This implies that the AC adapter is disconnected and
|
||||
all batteries are in critical or low capacity.
|
||||
The script shutdowns the system gracefully by default.
|
||||
.El
|
||||
.Pp
|
||||
The following events are defined for drive and battery sensors:
|
||||
.Bl -tag -width "sensor_temperature"
|
||||
.It Em state-changed
|
||||
The state on the sensor has been changed and it's not in normal state.
|
||||
The state of the sensor has been changed and it is not in the normal state.
|
||||
.El
|
||||
.Pp
|
||||
The following is an example of how a temperature sensor script might be
|
||||
|
Loading…
Reference in New Issue