Split "load" into "charge rate" and "discharge rate", depending on the state
of the battery.
This commit is contained in:
parent
f7d7184912
commit
cf1951c350
|
@ -1,4 +1,4 @@
|
|||
/* $NetBSD: acpi_bat.c,v 1.28 2003/11/01 09:49:45 mycroft Exp $ */
|
||||
/* $NetBSD: acpi_bat.c,v 1.29 2003/11/01 10:24:17 mycroft Exp $ */
|
||||
|
||||
/*-
|
||||
* Copyright (c) 2003 The NetBSD Foundation, Inc.
|
||||
|
@ -86,7 +86,7 @@
|
|||
*/
|
||||
|
||||
#include <sys/cdefs.h>
|
||||
__KERNEL_RCSID(0, "$NetBSD: acpi_bat.c,v 1.28 2003/11/01 09:49:45 mycroft Exp $");
|
||||
__KERNEL_RCSID(0, "$NetBSD: acpi_bat.c,v 1.29 2003/11/01 10:24:17 mycroft Exp $");
|
||||
|
||||
#include <sys/param.h>
|
||||
#include <sys/systm.h>
|
||||
|
@ -107,11 +107,12 @@ __KERNEL_RCSID(0, "$NetBSD: acpi_bat.c,v 1.28 2003/11/01 09:49:45 mycroft Exp $"
|
|||
#define ACPIBAT_WCAPACITY 5
|
||||
#define ACPIBAT_LCAPACITY 6
|
||||
#define ACPIBAT_VOLTAGE 7
|
||||
#define ACPIBAT_LOAD 8
|
||||
#define ACPIBAT_CAPACITY 9
|
||||
#define ACPIBAT_CHARGING 10
|
||||
#define ACPIBAT_DISCHARGING 11
|
||||
#define ACPIBAT_NSENSORS 12 /* number of sensors */
|
||||
#define ACPIBAT_CHARGERATE 8
|
||||
#define ACPIBAT_DISCHARGERATE 9
|
||||
#define ACPIBAT_CAPACITY 10
|
||||
#define ACPIBAT_CHARGING 11
|
||||
#define ACPIBAT_DISCHARGING 12
|
||||
#define ACPIBAT_NSENSORS 13 /* number of sensors */
|
||||
|
||||
const struct envsys_range acpibat_range_amp[] = {
|
||||
{ 0, 1, ENVSYS_SVOLTS_DC },
|
||||
|
@ -331,12 +332,13 @@ acpibat_clear_stat(struct acpibat_softc *sc)
|
|||
|
||||
if (sc->sc_available>ABAT_ALV_INFO)
|
||||
sc->sc_available = ABAT_ALV_INFO;
|
||||
sc->sc_data[ACPIBAT_LOAD].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_CHARGERATE].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_DISCHARGERATE].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_CAPACITY].validflags &= ~(ENVSYS_FCURVALID | ENVSYS_FFRACVALID);
|
||||
sc->sc_data[ACPIBAT_CAPACITY].warnflags = 0;
|
||||
sc->sc_data[ACPIBAT_VOLTAGE].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_CHARGING].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].validflags &= ~ENVSYS_FCURVALID;
|
||||
}
|
||||
|
||||
|
||||
|
@ -385,7 +387,6 @@ acpibat_get_info(struct acpibat_softc *sc)
|
|||
ACPI_STATUS rv;
|
||||
ACPI_BUFFER buf;
|
||||
int capunit, rateunit, s;
|
||||
const char *capstring, *ratestring;
|
||||
|
||||
rv = acpi_eval_struct(sc->sc_node->ad_handle, "_BIF", &buf);
|
||||
if (rv != AE_OK) {
|
||||
|
@ -421,23 +422,20 @@ acpibat_get_info(struct acpibat_softc *sc)
|
|||
ABAT_SET(sc, ABAT_F_PWRUNIT_MA);
|
||||
sc->sc_sysmon.sme_ranges = acpibat_range_amp;
|
||||
capunit = ENVSYS_SAMPHOUR;
|
||||
capstring = "charge";
|
||||
rateunit = ENVSYS_SAMPS;
|
||||
ratestring = "current";
|
||||
} else {
|
||||
ABAT_CLEAR(sc, ABAT_F_PWRUNIT_MA);
|
||||
sc->sc_sysmon.sme_ranges = acpibat_range_watt;
|
||||
capunit = ENVSYS_SWATTHOUR;
|
||||
capstring = "energy";
|
||||
rateunit = ENVSYS_SWATTS;
|
||||
ratestring = "power";
|
||||
}
|
||||
INITDATA(ACPIBAT_DCAPACITY, capunit, "design cap");
|
||||
INITDATA(ACPIBAT_LFCCAPACITY, capunit, "last full cap");
|
||||
INITDATA(ACPIBAT_WCAPACITY, capunit, "warn cap");
|
||||
INITDATA(ACPIBAT_LCAPACITY, capunit, "low cap");
|
||||
INITDATA(ACPIBAT_LOAD, rateunit, ratestring);
|
||||
INITDATA(ACPIBAT_CAPACITY, capunit, capstring);
|
||||
INITDATA(ACPIBAT_CHARGERATE, rateunit, "charge rate");
|
||||
INITDATA(ACPIBAT_DISCHARGERATE, rateunit, "discharge rate");
|
||||
INITDATA(ACPIBAT_CAPACITY, capunit, "charge");
|
||||
|
||||
sc->sc_data[ACPIBAT_DCAPACITY].cur.data_s = p2[1].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_DCAPACITY].validflags |= ENVSYS_FCURVALID;
|
||||
|
@ -503,13 +501,21 @@ acpibat_get_status(struct acpibat_softc *sc)
|
|||
|
||||
ABAT_LOCK(sc, s);
|
||||
status = p2[0].Integer.Value;
|
||||
sc->sc_data[ACPIBAT_LOAD].cur.data_s = p2[1].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_LOAD].validflags |= ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_CHARGERATE].validflags &= ~ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_DISCHARGERATE].validflags &= ~ENVSYS_FCURVALID;
|
||||
if (p2[1].Integer.Value != -1) {
|
||||
if (status & ACPIBAT_CHARGING) {
|
||||
sc->sc_data[ACPIBAT_CHARGERATE].cur.data_s = p2[1].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_CHARGERATE].validflags |= ENVSYS_FCURVALID;
|
||||
} else if (status & ACPIBAT_DISCHARGING) {
|
||||
sc->sc_data[ACPIBAT_DISCHARGERATE].cur.data_s = p2[1].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_DISCHARGERATE].validflags |= ENVSYS_FCURVALID;
|
||||
}
|
||||
}
|
||||
sc->sc_data[ACPIBAT_CAPACITY].cur.data_s = p2[2].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_CAPACITY].validflags |= ENVSYS_FCURVALID | ENVSYS_FFRACVALID;
|
||||
sc->sc_data[ACPIBAT_VOLTAGE].cur.data_s = p2[3].Integer.Value * 1000;
|
||||
sc->sc_data[ACPIBAT_VOLTAGE].validflags |= ENVSYS_FCURVALID;
|
||||
|
||||
flags = 0;
|
||||
if (sc->sc_data[ACPIBAT_CAPACITY].cur.data_s <
|
||||
sc->sc_data[ACPIBAT_WCAPACITY].cur.data_s)
|
||||
|
@ -517,12 +523,12 @@ acpibat_get_status(struct acpibat_softc *sc)
|
|||
if (status & ACPIBAT_ST_CRITICAL)
|
||||
flags |= ENVSYS_WARN_CRITUNDER;
|
||||
sc->sc_data[ACPIBAT_CAPACITY].warnflags = flags;
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].cur.data_s =
|
||||
((status & ACPIBAT_ST_DISCHARGING) != 0);
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].validflags |= ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_CHARGING].cur.data_s =
|
||||
((status & ACPIBAT_ST_CHARGING) != 0);
|
||||
sc->sc_data[ACPIBAT_CHARGING].validflags |= ENVSYS_FCURVALID;
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].cur.data_s =
|
||||
((status & ACPIBAT_ST_DISCHARGING) != 0);
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].validflags |= ENVSYS_FCURVALID;
|
||||
sc->sc_available = ABAT_ALV_STAT;
|
||||
ABAT_UNLOCK(sc, s);
|
||||
|
||||
|
@ -583,7 +589,11 @@ acpibat_print_stat(struct acpibat_softc *sc)
|
|||
SCALE(sc->sc_data[ACPIBAT_VOLTAGE].cur.data_s),
|
||||
SCALE(sc->sc_data[ACPIBAT_CAPACITY].cur.data_s), CAPUNITS(sc),
|
||||
percent,
|
||||
SCALE(sc->sc_data[ACPIBAT_LOAD].cur.data_s), RATEUNITS(sc));
|
||||
SCALE(sc->sc_data[ACPIBAT_CHARGING].cur.data_s ?
|
||||
sc->sc_data[ACPIBAT_CHARGERATE].cur.data_s :
|
||||
sc->sc_data[ACPIBAT_DISCHARGING].cur.data_s ?
|
||||
sc->sc_data[ACPIBAT_DISCHARGERATE].cur.data_s : 0),
|
||||
RATEUNITS(sc));
|
||||
}
|
||||
|
||||
static void
|
||||
|
@ -691,7 +701,6 @@ void
|
|||
acpibat_init_envsys(struct acpibat_softc *sc)
|
||||
{
|
||||
int capunit, rateunit, i;
|
||||
const char *capstring, *ratestring;
|
||||
|
||||
#if 0
|
||||
if (sc->sc_flags & ABAT_F_PWRUNIT_MA) {
|
||||
|
@ -699,16 +708,12 @@ acpibat_init_envsys(struct acpibat_softc *sc)
|
|||
/* XXX */
|
||||
sc->sc_sysmon.sme_ranges = acpibat_range_amp;
|
||||
capunit = ENVSYS_SAMPHOUR;
|
||||
capstring = "charge";
|
||||
rateunit = ENVSYS_SAMPS;
|
||||
ratestring = "current";
|
||||
#if 0
|
||||
} else {
|
||||
sc->sc_sysmon.sme_ranges = acpibat_range_watt;
|
||||
capunit = ENVSYS_SWATTHOUR;
|
||||
capstring = "energy";
|
||||
rateunit = ENVSYS_SWATTS;
|
||||
ratestring = "power";
|
||||
}
|
||||
#endif
|
||||
|
||||
|
@ -726,8 +731,9 @@ acpibat_init_envsys(struct acpibat_softc *sc)
|
|||
INITDATA(ACPIBAT_WCAPACITY, capunit, "warn cap");
|
||||
INITDATA(ACPIBAT_LCAPACITY, capunit, "low cap");
|
||||
INITDATA(ACPIBAT_VOLTAGE, ENVSYS_SVOLTS_DC, "voltage");
|
||||
INITDATA(ACPIBAT_LOAD, rateunit, ratestring);
|
||||
INITDATA(ACPIBAT_CAPACITY, capunit, capstring);
|
||||
INITDATA(ACPIBAT_CHARGERATE, rateunit, "charge rate");
|
||||
INITDATA(ACPIBAT_DISCHARGERATE, rateunit, "discharge rate");
|
||||
INITDATA(ACPIBAT_CAPACITY, capunit, "charge");
|
||||
INITDATA(ACPIBAT_CHARGING, ENVSYS_INDICATOR, "charging");
|
||||
INITDATA(ACPIBAT_DISCHARGING, ENVSYS_INDICATOR, "discharging");
|
||||
|
||||
|
|
Loading…