Document the need for zeroing out the first 64 blocks of a replacement
component in a failed RAID set in order to avoid potentially configuring RAId 1 sets with erroneous values taken from random extent data in the replacement component partitions.
This commit is contained in:
parent
56eac9ea53
commit
3dd51f1b7e
|
@ -1,4 +1,4 @@
|
|||
.\" $NetBSD: raidctl.8,v 1.61 2010/01/27 09:26:16 wiz Exp $
|
||||
.\" $NetBSD: raidctl.8,v 1.62 2011/07/28 18:25:22 buhrow Exp $
|
||||
.\"
|
||||
.\" Copyright (c) 1998, 2002 The NetBSD Foundation, Inc.
|
||||
.\" All rights reserved.
|
||||
|
@ -1597,5 +1597,17 @@ component ever fail \(em it is better to use RAID 0 and get the
|
|||
additional space and speed, than it is to use parity, but
|
||||
not keep the parity correct.
|
||||
At least with RAID 0 there is no perception of increased data security.
|
||||
.Pp
|
||||
When replacing a failed component of a RAID set, it is a good
|
||||
idea to zero out the first 64 blocks of the new component to insure the
|
||||
RAIDframe driver doesn't erroneously detect a component label in the
|
||||
new component. This is particularly true on
|
||||
.Em
|
||||
RAID 1
|
||||
sets because there is at most one correct component label in a failed RAID
|
||||
1 installation, and the RAIDframe driver picks the component label with the
|
||||
highest serial number and modification value as the authoritative source
|
||||
for the failed RAID set when choosing which component label to use to
|
||||
configure the RAID set.
|
||||
.Sh BUGS
|
||||
Hot-spare removal is currently not available.
|
||||
|
|