diff --git a/lib/libc/sys/shutdown.2 b/lib/libc/sys/shutdown.2 index 927e3bdf3295..f242ec50d679 100644 --- a/lib/libc/sys/shutdown.2 +++ b/lib/libc/sys/shutdown.2 @@ -1,4 +1,4 @@ -.\" $NetBSD: shutdown.2,v 1.5 1995/02/27 12:37:11 cgd Exp $ +.\" $NetBSD: shutdown.2,v 1.6 1998/04/25 10:42:33 kleink Exp $ .\" .\" Copyright (c) 1983, 1991, 1993 .\" The Regents of the University of California. All rights reserved. @@ -50,15 +50,18 @@ call causes all or part of a full-duplex connection on the socket associated with .Fa s to be shut down. -If +The .Fa how -is 0, further receives will be disallowed. -If -.Fa how -is 1, further sends will be disallowed. -If -.Fa how -is 2, further sends and receives will be disallowed. +argument specifies which part of the connection will be shut down. +Permissible values are: +.Bl -tag -width SHUT_RDWRXX -offset indent +.It SHUT_RD +further receives will be disallowed. +.It SHUT_RW +further sends will be disallowed. +.It SHUT_RDWR +further sends and receives will be disallowed. +.El .Sh DIAGNOSTICS A 0 is returned if the call succeeds, -1 if it fails. .Sh ERRORS